Morning Report for April 26, 1999
Headquarters Daily Report APRIL 26, 1999 *************************************************************************** REPORT NEGATIVE NO INPUT ATTACHED INPUT RECEIVED RECEIVED HEADQUARTERS X REGION I X REGION II X REGION III X REGION IV X PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION I APRIL 26, 1999 Licensee/Facility: Notification: Dept. Of Health And Human Services MR Number: 1-99-0017 National Institutes Of Health Date: 04/23/99 Bethesda,Maryland Dockets: 03008478 License No: 19-00296-17 Subject: MALFUNCTION OF J.L. SHEPHERD, MARK I IRRADIATOR Discussion: On April 23, 1999, the RSO for NIH informed Region I, Division of Nuclear Materials Safety, by telephone, that its J. L. Shepherd, Mark I irradiator had malfunctioned. NIH's license requires that they immediately stop use of the irradiator and notify the Commission by telephone if abnormal levels of radiation or any malfunction of the irradiator is detected. On April 21, 1999, NIH detected that the source had not fully retracted to the shielded position. The RSO indicated that there were no elevated radiation levels adjacent to the irradiator. NIH has taken the irradiator out of service and has contacted J. L. Shepherd for service. Regional Action: None Contact: J. Joustra (610)337-5355 _
Page Last Reviewed/Updated Wednesday, March 24, 2021