Event Notification Report for August 20, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/19/2026 - 08/20/2026
Agreement State
Event Number: 58332
Rep Org: Texas Dept of State Health Services
Licensee: Nextier Completion Solutions
Region: 4
City: Pearsall State: TX
County:
License #: L06712
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Ian Howard
Licensee: Nextier Completion Solutions
Region: 4
City: Pearsall State: TX
County:
License #: L06712
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Ian Howard
Notification Date: 06/26/2026
Notification Time: 20:02 [ET]
Event Date: 06/26/2026
Event Time: 00:00 [CDT]
Last Update Date: 08/19/2026
Notification Time: 20:02 [ET]
Event Date: 06/26/2026
Event Time: 00:00 [CDT]
Last Update Date: 08/19/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 8/20/2026
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER
The following information was provided by the Texas Department of State Health Services (the Agency) via phone and email:
"On June 26, 2026, the licensee reported that while attempting to close the shutter on a Berthold densitometer, their electronic technician had the shutter handle come off the device into his hand. The shutter was in the open position (which was verified with a survey meter) and could not be closed. The device is a Berthold LB8010 densitometer. The device's source is a cesium-137 source with an activity of 20 mCi (original activity). The incident happened on a wellsite near Pearsall, Texas. The device was transported in a Type A container to the licensee's facility and put into storage. The licensee reported the device will be disposed of on November 15, 2026. No individual received any significant exposure from this event. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident #: 10303
Texas NMED #: TX260021
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER
The following information was provided by the Texas Department of State Health Services (the Agency) via phone and email:
"On June 26, 2026, the licensee reported that while attempting to close the shutter on a Berthold densitometer, their electronic technician had the shutter handle come off the device into his hand. The shutter was in the open position (which was verified with a survey meter) and could not be closed. The device is a Berthold LB8010 densitometer. The device's source is a cesium-137 source with an activity of 20 mCi (original activity). The incident happened on a wellsite near Pearsall, Texas. The device was transported in a Type A container to the licensee's facility and put into storage. The licensee reported the device will be disposed of on November 15, 2026. No individual received any significant exposure from this event. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident #: 10303
Texas NMED #: TX260021
Agreement State
Event Number: 58361
Rep Org: Texas Dept of State Health Services
Licensee: The Dow Chemical Company
Region: 4
City: Lake Jackson State: TX
County:
License #: L00451
Agreement: Y
Docket:
NRC Notified By: Sindiso Ncube
HQ OPS Officer: Ian Howard
Licensee: The Dow Chemical Company
Region: 4
City: Lake Jackson State: TX
County:
License #: L00451
Agreement: Y
Docket:
NRC Notified By: Sindiso Ncube
HQ OPS Officer: Ian Howard
Notification Date: 07/15/2026
Notification Time: 09:58 [ET]
Event Date: 07/14/2026
Event Time: 00:00 [CDT]
Last Update Date: 08/19/2026
Notification Time: 09:58 [ET]
Event Date: 07/14/2026
Event Time: 00:00 [CDT]
Last Update Date: 08/19/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 8/20/2026
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER
The following information was provided by the Texas Department of State Health Services (the Agency) via phone and email:
"On July 15, 2026, the Agency received a notification from the licensee regarding a stuck source shutter on a density gauge. The gauge, a Vega SHF2 Model, contains a 200 millicurie cesium-137 sealed source. The licensee reported that the gauge was found with the source shutter stuck in the open position by technicians conducting routine shutdown operations at the facility on July 14, 2026. Open is the normal operating position. The licensee stated that no worker or members of the public received an unintended radiation dose as a result of this event. The licensee has also arranged the contractor to repair the gauge on July 17, 2026.
"Additional information will be made available in accordance with SA 300 reporting requirements."
Texas Incident Number: 10308
Texas NMED Number: TX260024
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER
The following information was provided by the Texas Department of State Health Services (the Agency) via phone and email:
"On July 15, 2026, the Agency received a notification from the licensee regarding a stuck source shutter on a density gauge. The gauge, a Vega SHF2 Model, contains a 200 millicurie cesium-137 sealed source. The licensee reported that the gauge was found with the source shutter stuck in the open position by technicians conducting routine shutdown operations at the facility on July 14, 2026. Open is the normal operating position. The licensee stated that no worker or members of the public received an unintended radiation dose as a result of this event. The licensee has also arranged the contractor to repair the gauge on July 17, 2026.
"Additional information will be made available in accordance with SA 300 reporting requirements."
Texas Incident Number: 10308
Texas NMED Number: TX260024
Agreement State
Event Number: 58406
Rep Org: Texas Dept of State Health Services
Licensee: Bonded Inspections INC
Region: 4
City: Wichita Falls State: TX
County:
License #: L 00693
Agreement: Y
Docket:
NRC Notified By: Sindiso Ncube
HQ OPS Officer: Christopher Prescott
Licensee: Bonded Inspections INC
Region: 4
City: Wichita Falls State: TX
County:
License #: L 00693
Agreement: Y
Docket:
NRC Notified By: Sindiso Ncube
HQ OPS Officer: Christopher Prescott
Notification Date: 08/11/2026
Notification Time: 19:44 [ET]
Event Date: 08/11/2026
Event Time: 06:00 [CDT]
Last Update Date: 08/19/2026
Notification Time: 19:44 [ET]
Event Date: 08/11/2026
Event Time: 06:00 [CDT]
Last Update Date: 08/19/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Einberg, Christian (NMSS)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Alexander, Ryan (RGLO)
Grant, Jeffery (IR)
Einberg, Christian (NMSS)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Alexander, Ryan (RGLO)
Grant, Jeffery (IR)
EN Revision Imported Date: 8/20/2026
EN Revision Text: AGREEMENT STATE REPORT - LOST SOURCE
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On August 11, 2026, the Department received notification from the licensee regarding a missing industrial radiography camera. The camera, an Industrial Nuclear Company [model] IR 100, contains a 90 Curie iridium-192 sealed source. The licensee stated that the trainer placed the camera at the back of the truck around 0600 CDT while preparing to leave the licensee's Wichita Falls office for a temporary jobsite in Weatherford [Texas]. The trainer did not place the camera inside the transport box and did not close the vehicle tailgate before departing. The trainer drove to the destination and realized upon arrival that the camera was missing and that the vehicle's tailgate was down. The radiation safety officer (RSO) stated that a team has been searching for the camera since this morning and will continue the search throughout the evening. The RSO stated that local law enforcement has been notified of the missing radioactive source in Wichita Falls. Additional information will be made available in accordance with SA-300 Reporting requirements."
Texas Incident number: 10318
Texas NMED number: TX260033
Notified DHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA Central Watch Officer, EPA EOC, FEMA NWC, FDA EOC (email), DHS Nuclear SSA (email), FEMA NRCC SASC (email), CWMD Watch Desk (email).
* * * UPDATE FROM ART TUCKER TO ERNEST WEST ON 08/12/2026 AT 1510 EDT * * *
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On August 12, 2026, two department investigators conducted a search for the missing camera and found it in Mineral Wells [Texas] at 1342 CDT. The source was found in a culvert at the intersection of highway 281 and 1821. The licensee has been informed and is enroute to collect the camera. Based on the location where the source was found, it does not appear that any individual would have received an exposure that would have approached any limit"
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The source was found in the fully shielded position and there was no damage to the radiography camera.
Notified NMSS (Allen), RGLO (Alexander), ILTAB Branch Chief (Brown), IR MOC (Grant), INES National Officer (Smith via email), ILTAB (email), NMSS Event Notification (email), CNSNS (email).
Notified DHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA Central Watch Officer, EPA EOC, FEMA NWC, FDA EOC (email), DHS Nuclear SSA (email), FEMA NRCC SASC (email), CWMD Watch Desk (email).
THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST SOURCE
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On August 11, 2026, the Department received notification from the licensee regarding a missing industrial radiography camera. The camera, an Industrial Nuclear Company [model] IR 100, contains a 90 Curie iridium-192 sealed source. The licensee stated that the trainer placed the camera at the back of the truck around 0600 CDT while preparing to leave the licensee's Wichita Falls office for a temporary jobsite in Weatherford [Texas]. The trainer did not place the camera inside the transport box and did not close the vehicle tailgate before departing. The trainer drove to the destination and realized upon arrival that the camera was missing and that the vehicle's tailgate was down. The radiation safety officer (RSO) stated that a team has been searching for the camera since this morning and will continue the search throughout the evening. The RSO stated that local law enforcement has been notified of the missing radioactive source in Wichita Falls. Additional information will be made available in accordance with SA-300 Reporting requirements."
Texas Incident number: 10318
Texas NMED number: TX260033
Notified DHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA Central Watch Officer, EPA EOC, FEMA NWC, FDA EOC (email), DHS Nuclear SSA (email), FEMA NRCC SASC (email), CWMD Watch Desk (email).
* * * UPDATE FROM ART TUCKER TO ERNEST WEST ON 08/12/2026 AT 1510 EDT * * *
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On August 12, 2026, two department investigators conducted a search for the missing camera and found it in Mineral Wells [Texas] at 1342 CDT. The source was found in a culvert at the intersection of highway 281 and 1821. The licensee has been informed and is enroute to collect the camera. Based on the location where the source was found, it does not appear that any individual would have received an exposure that would have approached any limit"
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The source was found in the fully shielded position and there was no damage to the radiography camera.
Notified NMSS (Allen), RGLO (Alexander), ILTAB Branch Chief (Brown), IR MOC (Grant), INES National Officer (Smith via email), ILTAB (email), NMSS Event Notification (email), CNSNS (email).
Notified DHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA Central Watch Officer, EPA EOC, FEMA NWC, FDA EOC (email), DHS Nuclear SSA (email), FEMA NRCC SASC (email), CWMD Watch Desk (email).
THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 58407
Rep Org: PA Bureau of Radiation Protection
Licensee: Duraloy Technologies Inc.
Region: 1
City: Scottsdale State: PA
County:
License #: PA-1281
Agreement: Y
Docket:
NRC Notified By: John S. Chippo
HQ OPS Officer: Sebastien Bruneau
Licensee: Duraloy Technologies Inc.
Region: 1
City: Scottsdale State: PA
County:
License #: PA-1281
Agreement: Y
Docket:
NRC Notified By: John S. Chippo
HQ OPS Officer: Sebastien Bruneau
Notification Date: 08/12/2026
Notification Time: 08:35 [ET]
Event Date: 08/10/2026
Event Time: 19:30 [EDT]
Last Update Date: 08/13/2026
Notification Time: 08:35 [ET]
Event Date: 08/10/2026
Event Time: 19:30 [EDT]
Last Update Date: 08/13/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK SHUTTER
The following information was provided by the Pennsylvania Bureau of Radiation Protection (the Department) via email:
"On August 10, 2026, [at approximately] 1930 [EDT], a radiographer was working at the licensee's permanent location and could not fully retract the source into the camera. The camera is a QSA Model 880 with a source assembly model QSA Model A424-9. It contains approximately 22 Ci [0.8 TBq] of Ir-192. The source was stuck [approximately] one inch from the locked position, so it was partially shielded. They were able to disconnect the crank and pull the source back into the locked position. Since then, the camera seems to be operating correctly, and the issue was with the crank. The licensee spoke with the manufacturer (QSA), and the maintenance technician they spoke to [also] seemed to think it was an issue with the crank. They will be sending the crank to QSA on August 12, 2026, for inspection and repair if possible."
PA NMED number: PA260015
* * * UPDATE FROM JOHN S. CHIPPO TO SEBASTIEN BRUNEAU ON 08/13/2026 AT 0826 EDT * * *
"The camera is a QSA Model 880 (Serial Number: D16035) with a source assembly model QSA Model A424-9 (Serial Number: 30570P)."
"The licensee installed a new drive cable assembly on August 12, 2026."
"The licensee estimates that the radiographer on duty received 3.5 mR during the 14-hour shift."
Notified NMSS Events Notifications (email)
The following information was provided by the Pennsylvania Bureau of Radiation Protection (the Department) via email:
"On August 10, 2026, [at approximately] 1930 [EDT], a radiographer was working at the licensee's permanent location and could not fully retract the source into the camera. The camera is a QSA Model 880 with a source assembly model QSA Model A424-9. It contains approximately 22 Ci [0.8 TBq] of Ir-192. The source was stuck [approximately] one inch from the locked position, so it was partially shielded. They were able to disconnect the crank and pull the source back into the locked position. Since then, the camera seems to be operating correctly, and the issue was with the crank. The licensee spoke with the manufacturer (QSA), and the maintenance technician they spoke to [also] seemed to think it was an issue with the crank. They will be sending the crank to QSA on August 12, 2026, for inspection and repair if possible."
PA NMED number: PA260015
* * * UPDATE FROM JOHN S. CHIPPO TO SEBASTIEN BRUNEAU ON 08/13/2026 AT 0826 EDT * * *
"The camera is a QSA Model 880 (Serial Number: D16035) with a source assembly model QSA Model A424-9 (Serial Number: 30570P)."
"The licensee installed a new drive cable assembly on August 12, 2026."
"The licensee estimates that the radiographer on duty received 3.5 mR during the 14-hour shift."
Notified NMSS Events Notifications (email)