Event Notification Report for April 23, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/22/2025 - 04/23/2025
Agreement State
Event Number: 57665
Rep Org: Utah Division of Radiation Control
Licensee: RB & G Engineering
Region: 4
City: Spanish Fork State: UT
County:
License #: UT 2500170
Agreement: Y
Docket:
NRC Notified By: Phillip Goble
HQ OPS Officer: Brian P. Smith
Licensee: RB & G Engineering
Region: 4
City: Spanish Fork State: UT
County:
License #: UT 2500170
Agreement: Y
Docket:
NRC Notified By: Phillip Goble
HQ OPS Officer: Brian P. Smith
Notification Date: 04/15/2025
Notification Time: 14:07 [ET]
Event Date: 04/15/2025
Event Time: 11:00 [MDT]
Last Update Date: 04/15/2025
Notification Time: 14:07 [ET]
Event Date: 04/15/2025
Event Time: 11:00 [MDT]
Last Update Date: 04/15/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED GAUGE
The following report was received by the Utah Department of Environmental Quality, Division of Waste Management and Radiation Control via email:
"On April 15, 2025, a testing crew was conducting density tests using a gauge with a cesium-137 source on a road that was closed and blocked off. A truck drove down the road at a high speed and almost hit the gauge operator and hit the gauge. Everyone within a 30-foot radius was evacuated. The licensee is waiting for some assistance. No clean-up has been performed, and it is unknown whether the source within the gauge has been ruptured or not."
Utah Event Number: UT250002
The following report was received by the Utah Department of Environmental Quality, Division of Waste Management and Radiation Control via email:
"On April 15, 2025, a testing crew was conducting density tests using a gauge with a cesium-137 source on a road that was closed and blocked off. A truck drove down the road at a high speed and almost hit the gauge operator and hit the gauge. Everyone within a 30-foot radius was evacuated. The licensee is waiting for some assistance. No clean-up has been performed, and it is unknown whether the source within the gauge has been ruptured or not."
Utah Event Number: UT250002
Agreement State
Event Number: 57667
Rep Org: Texas Dept of State Health Services
Licensee: Acend Performance Materials TX LLC
Region: 4
City: Alvin State: TX
County:
License #: L06630
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Karen Cotton-Gross
Licensee: Acend Performance Materials TX LLC
Region: 4
City: Alvin State: TX
County:
License #: L06630
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 04/15/2025
Notification Time: 19:30 [ET]
Event Date: 04/15/2025
Event Time: 00:00 [CDT]
Last Update Date: 04/16/2025
Notification Time: 19:30 [ET]
Event Date: 04/15/2025
Event Time: 00:00 [CDT]
Last Update Date: 04/16/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - FAILED SHUTTER
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On April 15, 2025, the Department was notified by the licensee that the shutter on a Kay Ray 7063 gauge had failed in the open position. Open is the normal position for the gauge. The gauge contains a 200 mCi (original activity) cesium-137 source. The licensee reported that there is no risk of additional radiation exposure to members of the general public or radiation workers.
"Additional information will be provided as received in accordance with SA-300."
Texas incident number: 10192
Texas NMED number: TX250024
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On April 15, 2025, the Department was notified by the licensee that the shutter on a Kay Ray 7063 gauge had failed in the open position. Open is the normal position for the gauge. The gauge contains a 200 mCi (original activity) cesium-137 source. The licensee reported that there is no risk of additional radiation exposure to members of the general public or radiation workers.
"Additional information will be provided as received in accordance with SA-300."
Texas incident number: 10192
Texas NMED number: TX250024
Agreement State
Event Number: 57668
Rep Org: California Radiation Control Prgm
Licensee: Cedars Sinai Medical Center
Region: 4
City: Los Angeles State: CA
County:
License #: 0404-19
Agreement: Y
Docket:
NRC Notified By: Thomas Miko
HQ OPS Officer: Brian P. Smith
Licensee: Cedars Sinai Medical Center
Region: 4
City: Los Angeles State: CA
County:
License #: 0404-19
Agreement: Y
Docket:
NRC Notified By: Thomas Miko
HQ OPS Officer: Brian P. Smith
Notification Date: 04/16/2025
Notification Time: 13:57 [ET]
Event Date: 04/14/2025
Event Time: 00:00 [PDT]
Last Update Date: 04/16/2025
Notification Time: 13:57 [ET]
Event Date: 04/14/2025
Event Time: 00:00 [PDT]
Last Update Date: 04/16/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following report was received by the California Radiation Control Program via email:
"On April 15, 2025, the radiation safety officer at Cedars Sinai Medical Center contacted Los Angeles County Public Health Radiation Management (part of the California Radiation Control Program), first by telephone at 0955 PDT and then by email at 1055 PDT, to report a medical event that occurred at Cedars Sinai Medical Center. During the administration of Y-90 TheraSpheres to a patient, the Y-90 TheraSpheres became obstructed within the intravenous tubing such that the authorized user was unable to administer the full dosage. The activity in the syringe was approximately 35 mCi, but only 12.14 mCi was delivered to the target organ. This was 35 percent of the prescribed activity. Additionally, the prescribed dose to the liver (the target organ) was 78.8 gray [7,880 rads]. The liver received a dose of 27.6 gray [2,760 rads], a difference of 51.2 gray [5,120 rads].
"A site visit by the principal radiation protection specialist, Los Angeles County Public Health Radiation Management is scheduled for April 17, 2025."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
California 5010 Number: 041525
The following report was received by the California Radiation Control Program via email:
"On April 15, 2025, the radiation safety officer at Cedars Sinai Medical Center contacted Los Angeles County Public Health Radiation Management (part of the California Radiation Control Program), first by telephone at 0955 PDT and then by email at 1055 PDT, to report a medical event that occurred at Cedars Sinai Medical Center. During the administration of Y-90 TheraSpheres to a patient, the Y-90 TheraSpheres became obstructed within the intravenous tubing such that the authorized user was unable to administer the full dosage. The activity in the syringe was approximately 35 mCi, but only 12.14 mCi was delivered to the target organ. This was 35 percent of the prescribed activity. Additionally, the prescribed dose to the liver (the target organ) was 78.8 gray [7,880 rads]. The liver received a dose of 27.6 gray [2,760 rads], a difference of 51.2 gray [5,120 rads].
"A site visit by the principal radiation protection specialist, Los Angeles County Public Health Radiation Management is scheduled for April 17, 2025."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
California 5010 Number: 041525
Power Reactor
Event Number: 57676
Facility: Columbia Generating Station
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: Curtis Clawson
HQ OPS Officer: Josue Ramirez
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: Curtis Clawson
HQ OPS Officer: Josue Ramirez
Notification Date: 04/22/2025
Notification Time: 14:17 [ET]
Event Date: 04/22/2025
Event Time: 08:00 [PDT]
Last Update Date: 04/22/2025
Notification Time: 14:17 [ET]
Event Date: 04/22/2025
Event Time: 08:00 [PDT]
Last Update Date: 04/22/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Rollins, Jesse (R4DO)
FFD Group, (EMAIL)
Rollins, Jesse (R4DO)
FFD Group, (EMAIL)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
2 | N | N | 0 | 0 |
FITNESS FOR DUTY REPORT
The following information was provided by the licensee via phone and email:
"A non-licensed supervisor had a confirmed positive fitness-for-duty follow-up test. The employee's unescorted access has been terminated. This report is being made pursuant to 10 CFR 26.719(b)(2)(ii).
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via phone and email:
"A non-licensed supervisor had a confirmed positive fitness-for-duty follow-up test. The employee's unescorted access has been terminated. This report is being made pursuant to 10 CFR 26.719(b)(2)(ii).
"The NRC Resident Inspector has been notified."
Independent Spent Fuel Storage Installation
Event Number: 57677
Rep Org: Oyster Creek
Licensee: Holtec International
Region: 1
City: Forked River State: NJ
County: Ocean
License #: GL
Agreement: N
Docket: 72-15
NRC Notified By: Michael Gilbert
HQ OPS Officer: Josue Ramirez
Licensee: Holtec International
Region: 1
City: Forked River State: NJ
County: Ocean
License #: GL
Agreement: N
Docket: 72-15
NRC Notified By: Michael Gilbert
HQ OPS Officer: Josue Ramirez
Notification Date: 04/22/2025
Notification Time: 21:30 [ET]
Event Date: 04/22/2025
Event Time: 18:03 [EDT]
Last Update Date: 04/23/2025
Notification Time: 21:30 [ET]
Event Date: 04/22/2025
Event Time: 18:03 [EDT]
Last Update Date: 04/23/2025
Emergency Class: Non Emergency
10 CFR Section:
72.75(b)(2) - Press Release/Offsite Notification
10 CFR Section:
72.75(b)(2) - Press Release/Offsite Notification
Person (Organization):
Ford, Monica (R1DO)
NMSS_Events_Notification, (EMAIL)
Ford, Monica (R1DO)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 4/23/2025
EN Revision Text: OFFSITE NOTIFICATION
The following information was provided by the licensee via phone:
On April 22, 2025, at 1803 EDT, a forest fire reached the Oyster Creek property. The station contacted local fire department and the Lacey Township police department for response. At approximately 1940 EDT, the fire within the property was extinguished. The fire company continued to monitor the fire outside the property boundary at the time of this notification. There was no radiological or fuel storage damage from this event.
The NRC Regional Inspector will be notified.
EN Revision Text: OFFSITE NOTIFICATION
The following information was provided by the licensee via phone:
On April 22, 2025, at 1803 EDT, a forest fire reached the Oyster Creek property. The station contacted local fire department and the Lacey Township police department for response. At approximately 1940 EDT, the fire within the property was extinguished. The fire company continued to monitor the fire outside the property boundary at the time of this notification. There was no radiological or fuel storage damage from this event.
The NRC Regional Inspector will be notified.
Hospital
Event Number: 57669
Rep Org: Mercy Hospital, St. Louis
Licensee: Mercy Hospital, St. Louis
Region: 3
City: St. Louis State: MO
County: St. Louis
License #: 24-00794-03
Agreement: N
Docket:
NRC Notified By: Jamie Eisenberg
HQ OPS Officer: Bill Nytko
Licensee: Mercy Hospital, St. Louis
Region: 3
City: St. Louis State: MO
County: St. Louis
License #: 24-00794-03
Agreement: N
Docket:
NRC Notified By: Jamie Eisenberg
HQ OPS Officer: Bill Nytko
Notification Date: 04/17/2025
Notification Time: 11:08 [ET]
Event Date: 01/24/2025
Event Time: 10:04 [CDT]
Last Update Date: 04/17/2025
Notification Time: 11:08 [ET]
Event Date: 01/24/2025
Event Time: 10:04 [CDT]
Last Update Date: 04/17/2025
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1)(i) - Dose <> Prescribed Dosage
10 CFR Section:
35.3045(a)(1)(i) - Dose <> Prescribed Dosage
Person (Organization):
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MEDICAL EVENT
The following information was provided by the licensee's radiation safety officer (RSO) via phone:
During an audit performed on 04/16/2025, it was discovered, that on 01/24/2025, a patient had received a dose to the liver that was greater than 20 percent of the prescribed dose. The prescribed activity was 24.3 mCi of Y-90 microsphere, an equivalent dose of 21.95 grays to the liver. The spreadsheet containing the activity verification incorrectly listed the activity as 26.9 mCi. The actual activity administered to the patient was 29.8 mCi, an equivalent dose of 26.9 grays, which is 22.6 percent (4.95 grays) greater than the prescribed dose to the liver. The RSO intends to contact the patient and doctor.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the licensee's radiation safety officer (RSO) via phone:
During an audit performed on 04/16/2025, it was discovered, that on 01/24/2025, a patient had received a dose to the liver that was greater than 20 percent of the prescribed dose. The prescribed activity was 24.3 mCi of Y-90 microsphere, an equivalent dose of 21.95 grays to the liver. The spreadsheet containing the activity verification incorrectly listed the activity as 26.9 mCi. The actual activity administered to the patient was 29.8 mCi, an equivalent dose of 26.9 grays, which is 22.6 percent (4.95 grays) greater than the prescribed dose to the liver. The RSO intends to contact the patient and doctor.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 57670
Rep Org: PA Bureau of Radiation Protection
Licensee: University of Pittsburgh
Region: 1
City: Pittsburgh State: PA
County:
License #: PA-0190
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Brian P. Smith
Licensee: University of Pittsburgh
Region: 1
City: Pittsburgh State: PA
County:
License #: PA-0190
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Brian P. Smith
Notification Date: 04/17/2025
Notification Time: 13:39 [ET]
Event Date: 04/16/2025
Event Time: 00:00 [EDT]
Last Update Date: 04/17/2025
Notification Time: 13:39 [ET]
Event Date: 04/16/2025
Event Time: 00:00 [EDT]
Last Update Date: 04/17/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following report was received by the Pennsylvania Bureau of Radiation Protection [the Department] via email:
"On April 16, 2025, a patient was receiving an iridium-192 treatment using an Elekta, Inc. microSelectron HDR [high-dose radiation] [remote afterloader]. During the procedure, a software error that retracted the source occurred. The unit was rebooted, and the treatment was restarted. However, 17 seconds into restarting, the unit failed to show the next dwell position, so the treatment was terminated. Approximately 48 percent of the prescribed dose was administered to the patient. No harm is expected to the patient and both the physician and patient were notified. The patient treatment plan will be updated accordingly.
"The official cause is still under investigation. The service engineer will be onsite April 17, 2025, to troubleshoot the HDR. The Department will perform a reactive inspection. More information will be provided as received."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Pennsylvania Event Report Number: PA250004
The following report was received by the Pennsylvania Bureau of Radiation Protection [the Department] via email:
"On April 16, 2025, a patient was receiving an iridium-192 treatment using an Elekta, Inc. microSelectron HDR [high-dose radiation] [remote afterloader]. During the procedure, a software error that retracted the source occurred. The unit was rebooted, and the treatment was restarted. However, 17 seconds into restarting, the unit failed to show the next dwell position, so the treatment was terminated. Approximately 48 percent of the prescribed dose was administered to the patient. No harm is expected to the patient and both the physician and patient were notified. The patient treatment plan will be updated accordingly.
"The official cause is still under investigation. The service engineer will be onsite April 17, 2025, to troubleshoot the HDR. The Department will perform a reactive inspection. More information will be provided as received."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Pennsylvania Event Report Number: PA250004
Independent Spent Fuel Storage Installation
Event Number: 57678
Rep Org: San Onofre
Licensee: Southern California Edison Company
Region: 4
City: San Clemente State: CA
County: San Diego
License #: GL
Agreement: Y
Docket: 72-41
NRC Notified By: Robert Doeing
HQ OPS Officer: Josue Ramirez
Licensee: Southern California Edison Company
Region: 4
City: San Clemente State: CA
County: San Diego
License #: GL
Agreement: Y
Docket: 72-41
NRC Notified By: Robert Doeing
HQ OPS Officer: Josue Ramirez
Notification Date: 04/23/2025
Notification Time: 21:07 [ET]
Event Date: 04/23/2025
Event Time: 15:54 [PDT]
Last Update Date: 04/23/2025
Notification Time: 21:07 [ET]
Event Date: 04/23/2025
Event Time: 15:54 [PDT]
Last Update Date: 04/23/2025
Emergency Class: Non Emergency
10 CFR Section:
72.75(b)(2) - Press Release/Offsite Notification
10 CFR Section:
72.75(b)(2) - Press Release/Offsite Notification
Person (Organization):
Rollins, Jesse (R4DO)
NMSS_Events_Notification, (EMAIL)
Rollins, Jesse (R4DO)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 4/24/2025
EN Revision Text: OFFSITE NOTIFICATION
The following is a summary of information provided by San Onofre Nuclear Generating Station (SONGS) via phone and email:
At 1554 PDT on 4/23/25, SONGS was notified of mineral oil spills that occurred in two separate locations from one transformer being delivered to SONGS. A total of 10-25 gallons of oil leaked. One leak location was on site and has been cleaned up. The second location was on state park property and has been isolated with absorbent material put down. A remediation company will remove the affected soil from the second location. The transformer has been drained and removed from the site. This report is being submitted due to offsite notifications to the San Diego Department of Environmental Health and the California Office of Emergency Services.
The NRC regional office has been notified.
EN Revision Text: OFFSITE NOTIFICATION
The following is a summary of information provided by San Onofre Nuclear Generating Station (SONGS) via phone and email:
At 1554 PDT on 4/23/25, SONGS was notified of mineral oil spills that occurred in two separate locations from one transformer being delivered to SONGS. A total of 10-25 gallons of oil leaked. One leak location was on site and has been cleaned up. The second location was on state park property and has been isolated with absorbent material put down. A remediation company will remove the affected soil from the second location. The transformer has been drained and removed from the site. This report is being submitted due to offsite notifications to the San Diego Department of Environmental Health and the California Office of Emergency Services.
The NRC regional office has been notified.