Event Notification Report for August 08, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/07/2023 - 08/08/2023

Power Reactor
Event Number: 56781
Facility: Diablo Canyon
Region: 4     State: CA
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: James Morris
HQ OPS Officer: Kerby Scales
Notification Date: 10/06/2023
Notification Time: 18:12 [ET]
Event Date: 08/08/2023
Event Time: 11:07 [PDT]
Last Update Date: 10/06/2023
Emergency Class: Non Emergency
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
Person (Organization):
Kellar, Ray (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 0 Refueling
Event Text
60 DAY NOTIFICATION FOR AN INVALID SPECIFIED SYSTEM ACTUATION

The following information was provided by the licensee via phone and email:

"This 60-day telephone notification is being made in accordance with 10 CFR 50.73(a)(1) and 10 CFR 50.73(a)(2)(iv)(A)."

"On August 8, 2023, at 1107 hours pacific daylight time (PDT) with Unit 1 in Mode 1 at 100 percent power, an invalid actuation occurred when Unit 1 4-kV vital bus 'G' was automatically transferred from auxiliary power to startup power due to an invalid bus under voltage signal, which occurred during planned maintenance activities.

"As a result of the actuation signal, auxiliary salt water and containment fan cooling units transferred automatically and started as designed. Plant systems responded as expected. This event was entered into the Diablo Canyon Power Plant corrective action program for resolution.

"There was no plant or public safety impact.

"The NRC Senior Resident Inspector has been notified."


Hospital
Event Number: 56666
Rep Org: Henry Ford Health
Licensee: Henry Ford Health
Region: 3
City: Detroit   State: MI
County:
License #: 21-04109-16
Agreement: N
Docket:
NRC Notified By: Nick Bevins
HQ OPS Officer: Thomas Herrity
Notification Date: 08/08/2023
Notification Time: 15:44 [ET]
Event Date: 08/08/2023
Event Time: 00:00 [EDT]
Last Update Date: 08/08/2023
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
Person (Organization):
Peterson, Hironori (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
MEDICAL EVENT - UNDERDOSE

The following is a summary of information provided by the licensee via telephone:

During post procedure processing of a Y-90 treatment to a liver, it was realized that only 78.5 percent (0.77 Giga-Becquerel) of the prescribed dose (0.99 Giga-Becquerel), was delivered to the target organ. The remainder of the dose was still in the delivery vial. All of the administered dose was delivered to the target organ. The prescribing physician has been informed. A written report will be forwarded when complete.

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.



Agreement State
Event Number: 56668
Rep Org: Texas Dept of State Health Services
Licensee: BRASKEM AMERICA INC
Region: 4
City: Freeport   State: TX
County:
License #: L06443
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Thomas Herrity
Notification Date: 08/08/2023
Notification Time: 19:04 [ET]
Event Date: 08/08/2023
Event Time: 00:00 [CDT]
Last Update Date: 08/08/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK OPEN SHUTTER

The following was received from the Texas Department of State Health Services (the Agency) via email:

"On August 8, 2023, the Agency was notified by the licensee's service provider that the shutter on a Vega America SH-F2 nuclear gauge would not close. Open is the normal position for the gauge. The gauge contains a sixty millicurie (original activity) Cs-137 source. The source is mounted in an elevated location that prevents exposures to any personnel. The service provider stated the licensee had just completed maintenance in the vessel where the gauge was mounted and was opening the shutter when they began to feel resistance to movement. The licensee continued to open the shutter and as they reached the open position the screws holding the operating arm in place broke. The operating arm no longer operates the shutter. The licensee will contact a service provider to repair the gauge. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident #: 10044



Fuel Cycle Facility
Event Number: 56670
Facility: Louisiana Energy Services
Region: 2     State: NM
Unit: [] [] []
RX Type:
Comments: Uranium Enrichment Facility
Gas Centrifuge Facility

NRC Notified By: Jim Rickman
HQ OPS Officer: John Russell
Notification Date: 08/09/2023
Notification Time: 16:26 [ET]
Event Date: 08/08/2023
Event Time: 14:22 [MDT]
Last Update Date: 08/09/2023
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (b)(1) - Unanalyzed Condition
Person (Organization):
Miller, Mark (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
UNANALYZED CONDITION

The following information was provided by the licensee via mail:

"It was determined that the Urenco United States of America (UUSA) safety analysis did not analyze for stacked, criticality safe (CSA) containers when not in an engineered storage array. This potentially results in an inadequate analysis.

"Urenco USA stores CSA containers in isolation on the floor and spaces them 60 centimeters apart, prior to performing IROFS [Items Relied on For Safety] 58a mass determination and placing a container in an array. However, an analysis has not determined whether dropping a container, or stacking a container, onto another container stored in this way, could result in exceeding the Code of Federal Regulations Title 10 Part 70.61 requirements. Currently, there are no containers stacked in this way.

"Urenco USA has stopped all work regarding moving the containers in areas affected by accident sequence DS1-9. The plant is in a safe and stable condition."


Power Reactor
Event Number: 56667
Facility: FitzPatrick
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: James Melville
HQ OPS Officer: Thomas Herrity
Notification Date: 08/08/2023
Notification Time: 17:03 [ET]
Event Date: 08/08/2023
Event Time: 00:00 [EDT]
Last Update Date: 08/08/2023
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Dimitriadis, Anthony (R1DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY TEST

The following information was provided by the licensee via email:

"A licensed (non-active) individual failed to comply with fitness for duty testing policies. The individual's unescorted access was terminated."