Event Notification Report for July 13, 2023
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/12/2023 - 07/13/2023
Agreement State
Event Number: 56608
Rep Org: Florida Bureau of Radiation Control
Licensee: Universal Engineering Sciences, LLC
Region: 1
City: St Petersburg State: FL
County:
License #: 4696-11
Agreement: Y
Docket:
NRC Notified By: Reno J. Fabii
HQ OPS Officer: Karen Cotton
Licensee: Universal Engineering Sciences, LLC
Region: 1
City: St Petersburg State: FL
County:
License #: 4696-11
Agreement: Y
Docket:
NRC Notified By: Reno J. Fabii
HQ OPS Officer: Karen Cotton
Notification Date: 07/05/2023
Notification Time: 16:21 [ET]
Event Date: 07/05/2023
Event Time: 00:00 [EDT]
Last Update Date: 07/05/2023
Notification Time: 16:21 [ET]
Event Date: 07/05/2023
Event Time: 00:00 [EDT]
Last Update Date: 07/05/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT- DAMAGED TROXLER GAUGE
The following information was provided by the Florida Bureau of Radiation Control via email:
"The Radiation Safety Officer (RSO) for Universal Engineering Sciences, reported that a Troxler gauge, possibly Model 3440, was improperly secured on the back of a truck, fell off, and was damaged. The gauge was in the shielded position but not in the case. The worker was able to retrieve the gauge from the road and secure it. The Troxler sources are believed to be intact. The local office RSO is in route to the location with radiation instruments and shielding (bucket of sand) to verify the sources were not breached. If the sources are found to be breached, they will be returned to Troxler for repair/disposal. No Bureau of Radiation Control assistance was requested."
Florida Incident Number: FL23-101
The following information was provided by the Florida Bureau of Radiation Control via email:
"The Radiation Safety Officer (RSO) for Universal Engineering Sciences, reported that a Troxler gauge, possibly Model 3440, was improperly secured on the back of a truck, fell off, and was damaged. The gauge was in the shielded position but not in the case. The worker was able to retrieve the gauge from the road and secure it. The Troxler sources are believed to be intact. The local office RSO is in route to the location with radiation instruments and shielding (bucket of sand) to verify the sources were not breached. If the sources are found to be breached, they will be returned to Troxler for repair/disposal. No Bureau of Radiation Control assistance was requested."
Florida Incident Number: FL23-101
Power Reactor
Event Number: 56618
Facility: North Anna
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP,[3] M-4-LP
NRC Notified By: Marc Hofmann
HQ OPS Officer: Kerby Scales
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP,[3] M-4-LP
NRC Notified By: Marc Hofmann
HQ OPS Officer: Kerby Scales
Notification Date: 07/11/2023
Notification Time: 17:42 [ET]
Event Date: 07/11/2023
Event Time: 15:30 [EDT]
Last Update Date: 07/11/2023
Notification Time: 17:42 [ET]
Event Date: 07/11/2023
Event Time: 15:30 [EDT]
Last Update Date: 07/11/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Miller, Mark (R2DO)
Miller, Mark (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION
The following information was provided by the licensee via email:
"At 1530 [EDT] on 7/11/2023, North Anna Power Station notified the Virginia Department of Environmental Quality (DEQ) that a small volume of filtered/purified water potentially discharged into Lake Anna from a leak from a reverse osmosis unit. The leak did not follow the normal release path for discharge through outfall 013. No environmental impact associated with this leak was observed or would be expected because the water in question is cleaner than the lake water, and would have met all discharge requirements for outfall 013.
"The NRC Resident Inspector was notified.
"This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi)."
The following information was provided by the licensee via email:
"At 1530 [EDT] on 7/11/2023, North Anna Power Station notified the Virginia Department of Environmental Quality (DEQ) that a small volume of filtered/purified water potentially discharged into Lake Anna from a leak from a reverse osmosis unit. The leak did not follow the normal release path for discharge through outfall 013. No environmental impact associated with this leak was observed or would be expected because the water in question is cleaner than the lake water, and would have met all discharge requirements for outfall 013.
"The NRC Resident Inspector was notified.
"This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi)."
Power Reactor
Event Number: 56620
Facility: Millstone
Region: 1 State: CT
Unit: [3] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Todd Stringfellow
HQ OPS Officer: Kerby Scales
Region: 1 State: CT
Unit: [3] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Todd Stringfellow
HQ OPS Officer: Kerby Scales
Notification Date: 07/12/2023
Notification Time: 12:49 [ET]
Event Date: 07/12/2023
Event Time: 04:49 [EDT]
Last Update Date: 07/12/2023
Notification Time: 12:49 [ET]
Event Date: 07/12/2023
Event Time: 04:49 [EDT]
Last Update Date: 07/12/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(B) - Pot Rhr Inop
10 CFR Section:
50.72(b)(3)(v)(B) - Pot Rhr Inop
Person (Organization):
Henrion, Mark (R1DO)
Henrion, Mark (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
ECCS POTENTIALLY INOPERABLE
The following information was provided by the licensee via email:
"At 0449 [EDT] on 7/12/2023, Millstone Unit 3 declared the 'B' train of the emergency core cooling system (ECCS) inoperable due to a degraded damper associated with the ventilation support system for the 'B' charging pump. At the time of this event, the 'A' train of service water was already inoperable due to planned maintenance on a breaker that would have prevented an 'A' service water valve powered from this breaker from closing on a safety signal. This configuration resulted in the possibility that the 'A' train of ECCS would not have been available to fulfill its design function under all postulated accident conditions. This event is being reported under 10 CFR 50.72(b)(3)(v)(B), '[any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to: (B) remove residual heat].'
"Subsequently, the 'A' train of service water was restored to operable at 0548 on 7/12/2023. Repairs and investigation continue on the 'B' train ECCS damper. The NRC resident has been notified. This event did not impact Millstone Unit 2. There was no impact to the public."
The following information was provided by the licensee via email:
"At 0449 [EDT] on 7/12/2023, Millstone Unit 3 declared the 'B' train of the emergency core cooling system (ECCS) inoperable due to a degraded damper associated with the ventilation support system for the 'B' charging pump. At the time of this event, the 'A' train of service water was already inoperable due to planned maintenance on a breaker that would have prevented an 'A' service water valve powered from this breaker from closing on a safety signal. This configuration resulted in the possibility that the 'A' train of ECCS would not have been available to fulfill its design function under all postulated accident conditions. This event is being reported under 10 CFR 50.72(b)(3)(v)(B), '[any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to: (B) remove residual heat].'
"Subsequently, the 'A' train of service water was restored to operable at 0548 on 7/12/2023. Repairs and investigation continue on the 'B' train ECCS damper. The NRC resident has been notified. This event did not impact Millstone Unit 2. There was no impact to the public."
Agreement State
Event Number: 56611
Rep Org: Ohio Bureau of Radiation Protection
Licensee: Geotechnical Consultants, Inc
Region: 3
City: Westerville State: OH
County:
License #: 31210250023
Agreement: Y
Docket:
NRC Notified By: Stephen James
HQ OPS Officer: Adam Koziol
Licensee: Geotechnical Consultants, Inc
Region: 3
City: Westerville State: OH
County:
License #: 31210250023
Agreement: Y
Docket:
NRC Notified By: Stephen James
HQ OPS Officer: Adam Koziol
Notification Date: 07/07/2023
Notification Time: 09:43 [ET]
Event Date: 06/29/2023
Event Time: 00:00 [EDT]
Last Update Date: 07/07/2023
Notification Time: 09:43 [ET]
Event Date: 06/29/2023
Event Time: 00:00 [EDT]
Last Update Date: 07/07/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
McCraw, Aaron (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
McCraw, Aaron (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - LOST AND RECOVERED GAUGE
The following information was provided by the Ohio Department of Health (ODH) via email:
"At approximately 1100 EDT on 6/29/23, ODH received notification from an Ohio radioactive materials licensee that a portable device containing radioactive sources had been lost. The device is a Troxler Model 3430 portable moisture/density gauge containing an 8 millicurie Cesium-137 source and a 40 millicurie Americium-241 source. The device had mistakenly been left on the tailgate of the technician's pickup truck when he left a jobsite to go to another work location. When the driver was stopped at an intersection, he saw in his rearview mirror that
the tailgate was open and stopped to verify the contents of the truck. At that point, he realized the gauge was missing. The technician had travelled approximately 13 miles before discovering that the device had been lost.
"The gauge was recovered later that same day (6/29/23) with no apparent damage."
Ohio Incident Number: OH230007
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the Ohio Department of Health (ODH) via email:
"At approximately 1100 EDT on 6/29/23, ODH received notification from an Ohio radioactive materials licensee that a portable device containing radioactive sources had been lost. The device is a Troxler Model 3430 portable moisture/density gauge containing an 8 millicurie Cesium-137 source and a 40 millicurie Americium-241 source. The device had mistakenly been left on the tailgate of the technician's pickup truck when he left a jobsite to go to another work location. When the driver was stopped at an intersection, he saw in his rearview mirror that
the tailgate was open and stopped to verify the contents of the truck. At that point, he realized the gauge was missing. The technician had travelled approximately 13 miles before discovering that the device had been lost.
"The gauge was recovered later that same day (6/29/23) with no apparent damage."
Ohio Incident Number: OH230007
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56613
Rep Org: Oregon Health Authority
Licensee: Central Geotechnical Services, LLC.
Region: 4
City: Salem State: OR
County:
License #: 91211
Agreement: Y
Docket:
NRC Notified By: Tom Pfahler
HQ OPS Officer: Sam Colvard
Licensee: Central Geotechnical Services, LLC.
Region: 4
City: Salem State: OR
County:
License #: 91211
Agreement: Y
Docket:
NRC Notified By: Tom Pfahler
HQ OPS Officer: Sam Colvard
Notification Date: 07/07/2023
Notification Time: 15:20 [ET]
Event Date: 07/07/2023
Event Time: 01:40 [PDT]
Last Update Date: 07/10/2023
Notification Time: 15:20 [ET]
Event Date: 07/07/2023
Event Time: 01:40 [PDT]
Last Update Date: 07/10/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED GAUGE
The following information is a summary provided by the Oregon Health Authority via phone and email:
On July 7, 2023, at 0140 PDT, a Troxler moisture density gauge (Model: 3411-B, Serial: 10464, 40 mCi Am/Be, 8.1 mCi Cs-137) was damaged by a construction vehicle. The source rod was bent, and the source locking mechanism was damaged. Central Geotechnical Services, LLC. (the licensee) reported no public exposure or contamination after a site survey. The damaged device was transported and secured at the licensee's office. The device will be leak tested and returned to the manufacturer.
Oregon incident number: 2023-1659
The following information is a summary provided by the Oregon Health Authority via phone and email:
On July 7, 2023, at 0140 PDT, a Troxler moisture density gauge (Model: 3411-B, Serial: 10464, 40 mCi Am/Be, 8.1 mCi Cs-137) was damaged by a construction vehicle. The source rod was bent, and the source locking mechanism was damaged. Central Geotechnical Services, LLC. (the licensee) reported no public exposure or contamination after a site survey. The damaged device was transported and secured at the licensee's office. The device will be leak tested and returned to the manufacturer.
Oregon incident number: 2023-1659