Event Notification Report for June 08, 2023
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/07/2023 - 06/08/2023
Power Reactor
Event Number: 56480
Facility: Comanche Peak
Region: 4 State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Joe Ricks
HQ OPS Officer: Adam Koziol
Region: 4 State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Joe Ricks
HQ OPS Officer: Adam Koziol
Notification Date: 04/20/2023
Notification Time: 13:29 [ET]
Event Date: 04/18/2023
Event Time: 16:30 [CDT]
Last Update Date: 06/07/2023
Notification Time: 13:29 [ET]
Event Date: 04/18/2023
Event Time: 16:30 [CDT]
Last Update Date: 06/07/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(A) - Pot Unable To Safe Sd 50.72(b)(3)(v)(D) - Accident Mitigation
10 CFR Section:
50.72(b)(3)(v)(A) - Pot Unable To Safe Sd 50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Werner, Greg (R4DO)
Werner, Greg (R4DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
EN Revision Imported Date: 6/8/2023
EN Revision Text: SAFE SHUTDOWN CAPABILITY AND ACCIDENT MITIGATION
The following information was provided by the licensee via email:
"Notification per 10 CFR 50.72 (b)(3)(v)(A) and (v)(D)
"At time 1630 CDT on 4/18/23, Comanche Peak Unit 1 entered TS (Technical Specification) 3.0.3 for 11 minutes due to declaring Train A component cooling water (CCW) inoperable in conjunction with a Train B centrifugal charging pump (CCP) inoperable for scheduled maintenance. This resulted in an event or condition that could have prevented fulfillment of a safety function, high head injection of the emergency core cooling system.
"CCP 1-02 and fan cooler were tagged out of service at 0400 CDT on 4/18/23 due to scheduled maintenance activities. Containment spray (CT) pump 1-03 seal oil cooler CCW leak was found by a watchstander at 0930 CDT on 4/18/23. Engineering determined that leakage was CCW from a pipe flange weld after insulation removal and could not [determine] operability and notified control room at 1630 CDT on 4/18/23. This placed unit 1 in a TS 3.0.3 condition from 1630 to 1641 CDT for approximately 11 minutes until CCP 1-02 was restored back to operable status. CCW was declared operable at 1912 after CT pump 1-03 seal oil cooler was isolated. CT pump 1-03 remained inoperable until weld repair completed. Train A CT pump 1-03 declared operable at 1211 CDT 4/19/23.
"ENS notification should have been made by 0030 CDT on 4/19/23. This report restores compliance."
The NRC Resident Inspector has been notified.
* * * RETRACTION ON 6/7/2023 AT 1000 EDT FROM CASEY DAVIES TO BILL GOTT * * *
The following information was provided by the licensee via phone and email:
"Although Comanche Peak Unit 1 conservatively entered a limiting condition for operation action statement and performed repairs immediately, further engineering inspection and evaluation concluded that the CCW system was fully able to provide the needed flow to the 1-03 CT pump seal coolers from the time of discovery (0930 CDT) until which time the piping was isolated for repairs. During this period, structural integrity of the joint was maintained, CCW inventory loss remained within acceptable limits, and CCW could perform its intended design and safety functions.
"Based on this revised operability determination, train A CCW was always operable, and TS 3.0.3 did not apply.
"Therefore, reportability requirements per 10 CFR 50.72 (b)(3)(v)(A) and (v)(D) did not apply, and a 60 day LER will not be submitted."
The licensee notified the NRC Resident Inspector.
Notified R4DO (Young)
EN Revision Text: SAFE SHUTDOWN CAPABILITY AND ACCIDENT MITIGATION
The following information was provided by the licensee via email:
"Notification per 10 CFR 50.72 (b)(3)(v)(A) and (v)(D)
"At time 1630 CDT on 4/18/23, Comanche Peak Unit 1 entered TS (Technical Specification) 3.0.3 for 11 minutes due to declaring Train A component cooling water (CCW) inoperable in conjunction with a Train B centrifugal charging pump (CCP) inoperable for scheduled maintenance. This resulted in an event or condition that could have prevented fulfillment of a safety function, high head injection of the emergency core cooling system.
"CCP 1-02 and fan cooler were tagged out of service at 0400 CDT on 4/18/23 due to scheduled maintenance activities. Containment spray (CT) pump 1-03 seal oil cooler CCW leak was found by a watchstander at 0930 CDT on 4/18/23. Engineering determined that leakage was CCW from a pipe flange weld after insulation removal and could not [determine] operability and notified control room at 1630 CDT on 4/18/23. This placed unit 1 in a TS 3.0.3 condition from 1630 to 1641 CDT for approximately 11 minutes until CCP 1-02 was restored back to operable status. CCW was declared operable at 1912 after CT pump 1-03 seal oil cooler was isolated. CT pump 1-03 remained inoperable until weld repair completed. Train A CT pump 1-03 declared operable at 1211 CDT 4/19/23.
"ENS notification should have been made by 0030 CDT on 4/19/23. This report restores compliance."
The NRC Resident Inspector has been notified.
* * * RETRACTION ON 6/7/2023 AT 1000 EDT FROM CASEY DAVIES TO BILL GOTT * * *
The following information was provided by the licensee via phone and email:
"Although Comanche Peak Unit 1 conservatively entered a limiting condition for operation action statement and performed repairs immediately, further engineering inspection and evaluation concluded that the CCW system was fully able to provide the needed flow to the 1-03 CT pump seal coolers from the time of discovery (0930 CDT) until which time the piping was isolated for repairs. During this period, structural integrity of the joint was maintained, CCW inventory loss remained within acceptable limits, and CCW could perform its intended design and safety functions.
"Based on this revised operability determination, train A CCW was always operable, and TS 3.0.3 did not apply.
"Therefore, reportability requirements per 10 CFR 50.72 (b)(3)(v)(A) and (v)(D) did not apply, and a 60 day LER will not be submitted."
The licensee notified the NRC Resident Inspector.
Notified R4DO (Young)
Agreement State
Event Number: 56545
Rep Org: Florida Bureau of Radiation Control
Licensee: Universal Engineering Sciences
Region: 1
City: Orlando State: FL
County:
License #: 4696-1
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Ernest West
Licensee: Universal Engineering Sciences
Region: 1
City: Orlando State: FL
County:
License #: 4696-1
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Ernest West
Notification Date: 05/31/2023
Notification Time: 10:36 [ET]
Event Date: 05/31/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Notification Time: 10:36 [ET]
Event Date: 05/31/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE - DAMAGED TROXLER GAUGE
The following information was provided by the Florida Department of Health Bureau of Radiation Control (BRC) via email:
"Universal Engineering Sciences Corporate Radiation Safety Officer (RSO) called the BRC Orlando [office] this morning to report one of their Troxler gauges was run over on a job site this morning. He stated the source rod was in the retracted and shielded position at the time of the accident. Unit apparently sustained housing damage. Local RSO was enroute with a radiation meter. A BRC inspector is also enroute."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The Troxler gauge involved contains nominal activity of 40 mCi of Am-241:Be and 8 mCi of Cs-137.
FL incident number: FL23-081
The following information was provided by the Florida Department of Health Bureau of Radiation Control (BRC) via email:
"Universal Engineering Sciences Corporate Radiation Safety Officer (RSO) called the BRC Orlando [office] this morning to report one of their Troxler gauges was run over on a job site this morning. He stated the source rod was in the retracted and shielded position at the time of the accident. Unit apparently sustained housing damage. Local RSO was enroute with a radiation meter. A BRC inspector is also enroute."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The Troxler gauge involved contains nominal activity of 40 mCi of Am-241:Be and 8 mCi of Cs-137.
FL incident number: FL23-081
Agreement State
Event Number: 56546
Rep Org: Florida Bureau of Radiation Control
Licensee: Santa Rosa Medical Center
Region: 1
City: Milton State: FL
County:
License #: 3356-1
Agreement: Y
Docket:
NRC Notified By: Ashley Pierre-Saint
HQ OPS Officer: Adam Koziol
Licensee: Santa Rosa Medical Center
Region: 1
City: Milton State: FL
County:
License #: 3356-1
Agreement: Y
Docket:
NRC Notified By: Ashley Pierre-Saint
HQ OPS Officer: Adam Koziol
Notification Date: 05/31/2023
Notification Time: 11:22 [ET]
Event Date: 05/28/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Notification Time: 11:22 [ET]
Event Date: 05/28/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Rivera-Capella, Gretchen (NMSS DAY)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Rivera-Capella, Gretchen (NMSS DAY)
AGREEMENT STATE REPORT - MEDICAL EVENT - INCORRECT TARGET ORGAN
The following information was provided by the Florida Department of Health Bureau of Radiation Control (BRC) via email:
"The Radiation Safety Officer (RSO) for Santa Rosa Medical Center, called the BRC to report an incident which occurred on Sunday 5/28/23. A technician was performing a lung scan on a patient and accidentally grabbed the wrong dose. The patient received 4 mCi of Tc-99 before the technician realized her mistake; whole dose would have been 10 mCi. The radiologist and the patient were both made aware of the incident.
"Licensing and technology is being asked to further investigate this incident."
The following additional information was obtained from the RSO:
The prescribed dose was 10 mCi of Tc-99 tagged for lung scan while the administered dose of Tc-99 was tagged for the liver. The total body effective dose equivalent to the patient was 80 mrem.
Florida Incident Number: FL23-082
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the Florida Department of Health Bureau of Radiation Control (BRC) via email:
"The Radiation Safety Officer (RSO) for Santa Rosa Medical Center, called the BRC to report an incident which occurred on Sunday 5/28/23. A technician was performing a lung scan on a patient and accidentally grabbed the wrong dose. The patient received 4 mCi of Tc-99 before the technician realized her mistake; whole dose would have been 10 mCi. The radiologist and the patient were both made aware of the incident.
"Licensing and technology is being asked to further investigate this incident."
The following additional information was obtained from the RSO:
The prescribed dose was 10 mCi of Tc-99 tagged for lung scan while the administered dose of Tc-99 was tagged for the liver. The total body effective dose equivalent to the patient was 80 mrem.
Florida Incident Number: FL23-082
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 56547
Rep Org: Florida Bureau of Radiation Control
Licensee: Florida State University
Region: 1
City: Tallahassee State: FL
County:
License #: 0032-10
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Brian P. Smith
Licensee: Florida State University
Region: 1
City: Tallahassee State: FL
County:
License #: 0032-10
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Brian P. Smith
Notification Date: 05/31/2023
Notification Time: 11:26 [ET]
Event Date: 05/18/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Notification Time: 11:26 [ET]
Event Date: 05/18/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MATERIAL IDENTIFIED IN INVENTORY NOT ON LICENSE
The following report was received by the Florida Bureau of Radiation Control (BRC):
"FSU [Florida State University] contacted BRC Radioactive Materials Licensing via written letter dated May 18th, 2023 regarding a request to add [Uranium] U-233, any form except aerosols, to their license #0032-10. BRC Tallahassee called BRC Orlando this morning at 0900 [EDT] to notify. During a recent inventory close-out process, they found approximately 1.71 mCi of U-233. After checking the U-233 against their license, it was noticed that the U-233 is currently not listed on their current license. After additional review of archival records, it was found that the listing of U-233 was a remnant of their license #0032-18. License #0032-18 was terminated in 2012. The material has not been used in decades. The U-233 will stay in their radioactive materials storage vault and will not be used for any research. The plan moving forward is to eventually transfer the U-233 to a new research laboratory at the Colorado School of Mines. An amendment to current license to add U-233 is needed for this transfer."
Florida Event Number: FL23-080
The following report was received by the Florida Bureau of Radiation Control (BRC):
"FSU [Florida State University] contacted BRC Radioactive Materials Licensing via written letter dated May 18th, 2023 regarding a request to add [Uranium] U-233, any form except aerosols, to their license #0032-10. BRC Tallahassee called BRC Orlando this morning at 0900 [EDT] to notify. During a recent inventory close-out process, they found approximately 1.71 mCi of U-233. After checking the U-233 against their license, it was noticed that the U-233 is currently not listed on their current license. After additional review of archival records, it was found that the listing of U-233 was a remnant of their license #0032-18. License #0032-18 was terminated in 2012. The material has not been used in decades. The U-233 will stay in their radioactive materials storage vault and will not be used for any research. The plan moving forward is to eventually transfer the U-233 to a new research laboratory at the Colorado School of Mines. An amendment to current license to add U-233 is needed for this transfer."
Florida Event Number: FL23-080
Agreement State
Event Number: 56548
Rep Org: North Carolina Department of Health
Licensee: The Breast Center of Greensboro
Region: 1
City: Greensboro State: NC
County:
License #: 041-1542-1
Agreement: Y
Docket:
NRC Notified By: Tawny Morgan
HQ OPS Officer: Sam Colvard
Licensee: The Breast Center of Greensboro
Region: 1
City: Greensboro State: NC
County:
License #: 041-1542-1
Agreement: Y
Docket:
NRC Notified By: Tawny Morgan
HQ OPS Officer: Sam Colvard
Notification Date: 06/01/2023
Notification Time: 12:56 [ET]
Event Date: 05/09/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Notification Time: 12:56 [ET]
Event Date: 05/09/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
AGREEMENT STATE REPORT - LOST MEDICAL SOURCE
The following is a summary of an email received from the North Carolina Department of Health and Human Services:
The Breast Center of Greensboro reported one lost brachytherapy seed (Iodine-125 in a preloaded 7 cm syringe, initial activity 255 microcuries, final activity 176 microcuries, order number 202385558, lot number 85558, satisfactory leak test on April 4, 2023) to the North Carolina Department of Health and Human Services on May 12, 2023. The lost source was identified during an inventory performed on May 9, 2023. An extensive search was performed but the seed was not located. The seed was most likely thrown away in a sharps container and is not believed to be stolen. Each medical procedure performed with this specific seed lot was audited with no abnormalities noted. Corrective actions include identifying each seed with a unique tracking number, updating use procedures, designating waste containers for seed use only, daily seed tracking when seeds are used, and retraining for all seed technicians.
North Carolina Event Number: NC230009
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of an email received from the North Carolina Department of Health and Human Services:
The Breast Center of Greensboro reported one lost brachytherapy seed (Iodine-125 in a preloaded 7 cm syringe, initial activity 255 microcuries, final activity 176 microcuries, order number 202385558, lot number 85558, satisfactory leak test on April 4, 2023) to the North Carolina Department of Health and Human Services on May 12, 2023. The lost source was identified during an inventory performed on May 9, 2023. An extensive search was performed but the seed was not located. The seed was most likely thrown away in a sharps container and is not believed to be stolen. Each medical procedure performed with this specific seed lot was audited with no abnormalities noted. Corrective actions include identifying each seed with a unique tracking number, updating use procedures, designating waste containers for seed use only, daily seed tracking when seeds are used, and retraining for all seed technicians.
North Carolina Event Number: NC230009
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56549
Rep Org: Minnesota Department of Health
Licensee: Regions Hospital
Region: 3
City: St. Paul State: MN
County:
License #: 1026
Agreement: Y
Docket:
NRC Notified By: Tyler Kruse
HQ OPS Officer: John Russell
Licensee: Regions Hospital
Region: 3
City: St. Paul State: MN
County:
License #: 1026
Agreement: Y
Docket:
NRC Notified By: Tyler Kruse
HQ OPS Officer: John Russell
Notification Date: 06/01/2023
Notification Time: 15:34 [ET]
Event Date: 05/23/2023
Event Time: 00:00 [CDT]
Last Update Date: 06/01/2023
Notification Time: 15:34 [ET]
Event Date: 05/23/2023
Event Time: 00:00 [CDT]
Last Update Date: 06/01/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Skokowski, Richard (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSC (Canada), - (EMAIL)
Skokowski, Richard (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSC (Canada), - (EMAIL)
AGREEMENT STATE REPORT - LOST IODINE LOCALIZATION SEED
The following was received by email from the Minnesota Department of Health:
"An Iodine-125 localization seed (approximately 270 microcuries) was lost following removal from the specimen. The seed is suspected to have been placed on a surgical towel and never put into the source vial. Prior to discovery of the missing seed, the pathology department linens were taken to a laundry facility where the towel was washed. The licensee surveyed the pathology department and the laundry facility and were not able to find the seed."
State event report number: MN230003
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following was received by email from the Minnesota Department of Health:
"An Iodine-125 localization seed (approximately 270 microcuries) was lost following removal from the specimen. The seed is suspected to have been placed on a surgical towel and never put into the source vial. Prior to discovery of the missing seed, the pathology department linens were taken to a laundry facility where the towel was washed. The licensee surveyed the pathology department and the laundry facility and were not able to find the seed."
State event report number: MN230003
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 56560
Facility: Three Mile Island
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: Craig Smith
HQ OPS Officer: Sam Colvard
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: Craig Smith
HQ OPS Officer: Sam Colvard
Notification Date: 06/06/2023
Notification Time: 13:19 [ET]
Event Date: 06/06/2023
Event Time: 09:37 [EDT]
Last Update Date: 06/06/2023
Notification Time: 13:19 [ET]
Event Date: 06/06/2023
Event Time: 09:37 [EDT]
Last Update Date: 06/06/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Werkheiser, Dave (R1DO)
Russell Felts (NRR)
Anthony Ulses (IR MOC)
Werkheiser, Dave (R1DO)
Russell Felts (NRR)
Anthony Ulses (IR MOC)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Defueled | 0 | Defueled |
OFFSITE NOTIFICATION DUE TO ON-SITE FATALITY
The following information was provided by the licensee via email:
"At 0937 EDT on June 6, 2023, it was discovered that a site employee suffered a non-work-related fatality. The individual was found non-responsive outside the Radiological Controlled Area. This is a four-hour, non-emergency notification for which a notification to other government agencies has been made. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi). The NRC Region I inspector has been notified."
The following information was provided by the licensee via email:
"At 0937 EDT on June 6, 2023, it was discovered that a site employee suffered a non-work-related fatality. The individual was found non-responsive outside the Radiological Controlled Area. This is a four-hour, non-emergency notification for which a notification to other government agencies has been made. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi). The NRC Region I inspector has been notified."
Power Reactor
Event Number: 56561
Facility: Callaway
Region: 4 State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Dennis Hugo
HQ OPS Officer: Sam Colvard
Region: 4 State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Dennis Hugo
HQ OPS Officer: Sam Colvard
Notification Date: 06/07/2023
Notification Time: 11:00 [ET]
Event Date: 06/06/2023
Event Time: 12:33 [CDT]
Last Update Date: 06/07/2023
Notification Time: 11:00 [ET]
Event Date: 06/06/2023
Event Time: 12:33 [CDT]
Last Update Date: 06/07/2023
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Young, Cale (R4DO)
FFD Group, (EMAIL)
Young, Cale (R4DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
FITNESS-FOR-DUTY REPORT
The following information is summary provided by the licensee via email:
A non-licensed supervisor was found to have falsified fitness for duty reports for a period of two months. The employee's access to the plant has been terminated.
The NRC Resident Inspector has been notified.
The following information is summary provided by the licensee via email:
A non-licensed supervisor was found to have falsified fitness for duty reports for a period of two months. The employee's access to the plant has been terminated.
The NRC Resident Inspector has been notified.
Agreement State
Event Number: 56552
Rep Org: SC Dept of Health & Env Control
Licensee: Medical University Hospital Auth.
Region: 1
City: Charleston State: SC
County:
License #: 081
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Thomas Herrity
Licensee: Medical University Hospital Auth.
Region: 1
City: Charleston State: SC
County:
License #: 081
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Thomas Herrity
Notification Date: 06/02/2023
Notification Time: 11:39 [ET]
Event Date: 04/21/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/02/2023
Notification Time: 11:39 [ET]
Event Date: 04/21/2023
Event Time: 00:00 [EDT]
Last Update Date: 06/02/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
AGREEMENT STATE - LOST BRACHYTHERAPY SOURCE
The following was received by email from the South Carolina Department of Health and Environmental Control (The Department):
"The Department was notified on 05/09/23, that that one (1) Iodine-125 manual brachytherapy sealed source was lost or missing. The sealed source is a Bard Brachytherapy, Inc. Model STM 1251 with an activity of 0.34 mCi (12.58 MBq). The licensee reported that during a prostate seed implant procedure that occurred on 04/21/23, a single seed was possibly lost and remains unaccounted for. The licensee reported that during the procedure, an incorrectly configured strand was identified in the QuickLink device. This strand was ejected into the transfer device then pushed out into the sterile shielded shipping container so that the loose seeds could be counted. When assessing the seeds in the container, it was observed that one of the two I-125 seeds in this strand was missing. The medical physicists used a Geiger-Mueller counter to immediately survey the sterile cart and surrounding areas. The cart, floor, physician hands, nurse hands, and scrubs were all surveyed and no exposure was detected above background. Several other area surveys were also performed after the procedure was completed. The manual brachytherapy sealed source could not be accounted for.
"Department inspectors were dispatched to the facility on 05/17/23, and were unable to locate the missing sealed source. This event is still under investigation by the South Carolina Department of Health and Environmental Control."
SC internal ID number is: SC230011
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following was received by email from the South Carolina Department of Health and Environmental Control (The Department):
"The Department was notified on 05/09/23, that that one (1) Iodine-125 manual brachytherapy sealed source was lost or missing. The sealed source is a Bard Brachytherapy, Inc. Model STM 1251 with an activity of 0.34 mCi (12.58 MBq). The licensee reported that during a prostate seed implant procedure that occurred on 04/21/23, a single seed was possibly lost and remains unaccounted for. The licensee reported that during the procedure, an incorrectly configured strand was identified in the QuickLink device. This strand was ejected into the transfer device then pushed out into the sterile shielded shipping container so that the loose seeds could be counted. When assessing the seeds in the container, it was observed that one of the two I-125 seeds in this strand was missing. The medical physicists used a Geiger-Mueller counter to immediately survey the sterile cart and surrounding areas. The cart, floor, physician hands, nurse hands, and scrubs were all surveyed and no exposure was detected above background. Several other area surveys were also performed after the procedure was completed. The manual brachytherapy sealed source could not be accounted for.
"Department inspectors were dispatched to the facility on 05/17/23, and were unable to locate the missing sealed source. This event is still under investigation by the South Carolina Department of Health and Environmental Control."
SC internal ID number is: SC230011
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 56564
Facility: Seabrook
Region: 1 State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Andrew Ferraioli
HQ OPS Officer: Kerby Scales
Region: 1 State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Andrew Ferraioli
HQ OPS Officer: Kerby Scales
Notification Date: 06/08/2023
Notification Time: 09:37 [ET]
Event Date: 04/12/2023
Event Time: 11:07 [EDT]
Last Update Date: 06/08/2023
Notification Time: 09:37 [ET]
Event Date: 04/12/2023
Event Time: 11:07 [EDT]
Last Update Date: 06/08/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Werkheiser, Dave (R1DO)
Werkheiser, Dave (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 100 | Power Operation |
AUTOMATIC ACTUATION OF "B" EMERGENCY DIESEL GENERATOR EMERGENCY POWER SEQUENCER
The following information was provided by the licensee via email:
"On April 12, 2023, with Seabrook Station Unit 1 in Mode 6 at zero percent power, a valid actuation of the 'B' emergency diesel generator (EDG) emergency power sequencer occurred due to a loss of power to the 'B' train emergency bus. The 'B' EDG was removed from service for scheduled maintenance during this time.
"This event is being reported pursuant to 10 CFR 50.72(b)(3)(iv)(A) for a valid actuation of the 'B' EDG emergency power sequencer.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"On April 12, 2023, with Seabrook Station Unit 1 in Mode 6 at zero percent power, a valid actuation of the 'B' emergency diesel generator (EDG) emergency power sequencer occurred due to a loss of power to the 'B' train emergency bus. The 'B' EDG was removed from service for scheduled maintenance during this time.
"This event is being reported pursuant to 10 CFR 50.72(b)(3)(iv)(A) for a valid actuation of the 'B' EDG emergency power sequencer.
"The NRC Resident Inspector has been notified."
Power Reactor
Event Number: 56565
Facility: Seabrook
Region: 1 State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Andrew Ferraioli
HQ OPS Officer: Kerby Scales
Region: 1 State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Andrew Ferraioli
HQ OPS Officer: Kerby Scales
Notification Date: 06/08/2023
Notification Time: 09:37 [ET]
Event Date: 05/06/2023
Event Time: 15:52 [EDT]
Last Update Date: 06/08/2023
Notification Time: 09:37 [ET]
Event Date: 05/06/2023
Event Time: 15:52 [EDT]
Last Update Date: 06/08/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Werkheiser, Dave (R1DO)
Werkheiser, Dave (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Hot Standby | 100 | Power Operation |
ACTUATIONS OF REACTOR PROTECTION SYSTEM
The following information was provided by the licensee via email:
"On 05/06/2023, at 1552 [EDT] with Seabrook Unit 1 in Mode 3 at zero percent power, while performing digital rod position indication system surveillance testing, shutdown bank 'E' stopped withdrawing. In response, the reactor trip breakers were manually opened, initiating a valid actuation of the reactor protection system (RPS).
"Subsequently, at 2253 while continuing to perform digital rod position indication system surveillance testing, shutdown bank 'C 'stopped inserting. Reactor trip breakers were manually opened, initiating a valid actuation of the RPS.
"The RPS responded as designed during both events, and both actuations are being reported pursuant to 10 CFR 50.72(b)(3)(iv)(A).
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"On 05/06/2023, at 1552 [EDT] with Seabrook Unit 1 in Mode 3 at zero percent power, while performing digital rod position indication system surveillance testing, shutdown bank 'E' stopped withdrawing. In response, the reactor trip breakers were manually opened, initiating a valid actuation of the reactor protection system (RPS).
"Subsequently, at 2253 while continuing to perform digital rod position indication system surveillance testing, shutdown bank 'C 'stopped inserting. Reactor trip breakers were manually opened, initiating a valid actuation of the RPS.
"The RPS responded as designed during both events, and both actuations are being reported pursuant to 10 CFR 50.72(b)(3)(iv)(A).
"The NRC Resident Inspector has been notified."
Non-Agreement State
Event Number: 56566
Rep Org: Mistras Group, Inc.
Licensee: Mistras Group, Inc.
Region: 3
City: Burr Ridge State: IL
County:
License #: 12-16559-02
Agreement: N
Docket:
NRC Notified By: Mike Kim
HQ OPS Officer: Sam Colvard
Licensee: Mistras Group, Inc.
Region: 3
City: Burr Ridge State: IL
County:
License #: 12-16559-02
Agreement: N
Docket:
NRC Notified By: Mike Kim
HQ OPS Officer: Sam Colvard
Notification Date: 06/08/2023
Notification Time: 14:14 [ET]
Event Date: 06/07/2023
Event Time: 00:00 [CDT]
Last Update Date: 06/08/2023
Notification Time: 14:14 [ET]
Event Date: 06/07/2023
Event Time: 00:00 [CDT]
Last Update Date: 06/08/2023
Emergency Class: Non Emergency
10 CFR Section:
20.2202(b)(2) - Excessive Release 1xali
10 CFR Section:
20.2202(b)(2) - Excessive Release 1xali
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Young, Cale (R4DO)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Young, Cale (R4DO)
Nguyen, April (R3DO)
TEMPORARY LOSS OF CONTROL OF RADIOGRAPHY EXPOSURE DEVICE
The following is a summary of information provided by the licensee via phone and email:
On 6/7/23 at 1040 ADT, the licensee (Mistras Group, Inc.) was providing gamma radiography services in Prudhoe Bay, Alaska when an industrial radiography source (QSA 880 Delta, SN 73648M, Ir-192, 115.6 Ci) cable failed to retract. The device was moved safely to a location where repairs were made to the cable. No overexposures were associated with this event or during recovery operations. No radiation exposure was received by the general public.
The following is a summary of information provided by the licensee via phone and email:
On 6/7/23 at 1040 ADT, the licensee (Mistras Group, Inc.) was providing gamma radiography services in Prudhoe Bay, Alaska when an industrial radiography source (QSA 880 Delta, SN 73648M, Ir-192, 115.6 Ci) cable failed to retract. The device was moved safely to a location where repairs were made to the cable. No overexposures were associated with this event or during recovery operations. No radiation exposure was received by the general public.