Event Notification Report for April 18, 2023
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/17/2023 - 04/18/2023
Agreement State
Event Number: 56461
Rep Org: SC Dept of Health & Env Control
Licensee: Insight Health Corporation
Region: 1
City: West Columbia State: SC
County:
License #: 768
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Sam Colvard
Licensee: Insight Health Corporation
Region: 1
City: West Columbia State: SC
County:
License #: 768
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Sam Colvard
Notification Date: 04/10/2023
Notification Time: 14:40 [ET]
Event Date: 03/24/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/10/2023
Notification Time: 14:40 [ET]
Event Date: 03/24/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/10/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - POSSIBLE OVEREXPOSURE DOSE FOR AN EMBRYO/FETUS OF A DECLARED PREGNANT WOMAN
The following was received from the South Carolina Department of Health and Environmental Control (the Department) via email:
"On 03/24/23, at 1446 [EDT], the Department was notified by the licensee of a dose more than the dose limit for an embryo/fetus of a declared pregnant woman. A written report was also submitted on 03/24/23. The employee is a Technical Assistant for mobile [positron emission tomography/computed tomography] (PET/CT) operations and is not directly involved with handling radioactive material. The estimated dose reported was 1145 mrem [deep dose equivalent] (DDE) for a one-month period, the cumulative dose was 1239 mrem DDE. The licensee's report indicated it is possible that the badge may have been in the PET/CT scanner room during patient scans, but the employee could not recall that this ever happened. The licensee also reported the chest and control badges showed no elevated readings; only the fetal badge. The licensee's corrective actions included discussing with the employee the importance of making sure the badge is never left in a radiation area, and while at work, the badge is always worn properly for the entire day. Proper storage of badges next to the control badge was also discussed. The Department performed an on-site investigation on 03/29/23, and the information obtained during the on-site investigation was consistent with the licensee's written report. This event is considered closed."
South Carolina Department of Health and Environmental Control report no.: SC230008
The following was received from the South Carolina Department of Health and Environmental Control (the Department) via email:
"On 03/24/23, at 1446 [EDT], the Department was notified by the licensee of a dose more than the dose limit for an embryo/fetus of a declared pregnant woman. A written report was also submitted on 03/24/23. The employee is a Technical Assistant for mobile [positron emission tomography/computed tomography] (PET/CT) operations and is not directly involved with handling radioactive material. The estimated dose reported was 1145 mrem [deep dose equivalent] (DDE) for a one-month period, the cumulative dose was 1239 mrem DDE. The licensee's report indicated it is possible that the badge may have been in the PET/CT scanner room during patient scans, but the employee could not recall that this ever happened. The licensee also reported the chest and control badges showed no elevated readings; only the fetal badge. The licensee's corrective actions included discussing with the employee the importance of making sure the badge is never left in a radiation area, and while at work, the badge is always worn properly for the entire day. Proper storage of badges next to the control badge was also discussed. The Department performed an on-site investigation on 03/29/23, and the information obtained during the on-site investigation was consistent with the licensee's written report. This event is considered closed."
South Carolina Department of Health and Environmental Control report no.: SC230008
Agreement State
Event Number: 56462
Rep Org: Texas Dept of State Health Services
Licensee: PRECISION NDT LLC
Region: 4
City: Orla State: TX
County:
License #: L07054
Agreement: Y
Docket:
NRC Notified By: Karen Blanchard
HQ OPS Officer: Ernest West
Licensee: PRECISION NDT LLC
Region: 4
City: Orla State: TX
County:
License #: L07054
Agreement: Y
Docket:
NRC Notified By: Karen Blanchard
HQ OPS Officer: Ernest West
Notification Date: 04/10/2023
Notification Time: 18:42 [ET]
Event Date: 04/07/2023
Event Time: 00:00 [CDT]
Last Update Date: 04/10/2023
Notification Time: 18:42 [ET]
Event Date: 04/07/2023
Event Time: 00:00 [CDT]
Last Update Date: 04/10/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE - DAMAGED RADIOGRAPHY GUIDE TUBE PREVENTING RETRACTION OF SOURCE
The following information was provided by the Texas Department of State Health Services (the Agency) via email:
"On April 10, 2023, the licensee reported to the Agency that on April 7, 2023, one of its QSA Delta 880 industrial radiography exposure devices (camera) had fallen approximately three feet onto the source guide tube at a job site in Orla, Texas. The camera severed the guide tube and the source pigtail was disconnected from the drive cable. The source was 72 curies of iridium-192. A boundary was set at 2 millirem by the radiographers and an individual authorized on their license was dispatched to the site and retrieved the source. The retriever's dosimeter indicated a whole-body dose of 2.6 rem. The licensee has reported initial calculations for the retriever's hand dose to be 385.9 millirem. The two radiographer's self-reading pocket dosimeters indicated doses of 180 and 150 millirem. All of the equipment is being sent to the manufacturer for evaluation. An investigation into this event is ongoing. More information will be provided as it is obtained in accordance with SA-300."
Texas Incident Number: I-10007
The following information was provided by the Texas Department of State Health Services (the Agency) via email:
"On April 10, 2023, the licensee reported to the Agency that on April 7, 2023, one of its QSA Delta 880 industrial radiography exposure devices (camera) had fallen approximately three feet onto the source guide tube at a job site in Orla, Texas. The camera severed the guide tube and the source pigtail was disconnected from the drive cable. The source was 72 curies of iridium-192. A boundary was set at 2 millirem by the radiographers and an individual authorized on their license was dispatched to the site and retrieved the source. The retriever's dosimeter indicated a whole-body dose of 2.6 rem. The licensee has reported initial calculations for the retriever's hand dose to be 385.9 millirem. The two radiographer's self-reading pocket dosimeters indicated doses of 180 and 150 millirem. All of the equipment is being sent to the manufacturer for evaluation. An investigation into this event is ongoing. More information will be provided as it is obtained in accordance with SA-300."
Texas Incident Number: I-10007
Hospital
Event Number: 56463
Rep Org: Community Health Network, North Hospital
Licensee: Community Health Network, North Hospital
Region: 3
City: Indianapolis State: IN
County:
License #: 13-06009-01
Agreement: N
Docket:
NRC Notified By: Erin Bell
HQ OPS Officer: Donald Norwood
Licensee: Community Health Network, North Hospital
Region: 3
City: Indianapolis State: IN
County:
License #: 13-06009-01
Agreement: N
Docket:
NRC Notified By: Erin Bell
HQ OPS Officer: Donald Norwood
Notification Date: 04/11/2023
Notification Time: 08:39 [ET]
Event Date: 04/10/2023
Event Time: 12:00 [EDT]
Last Update Date: 04/11/2023
Notification Time: 08:39 [ET]
Event Date: 04/10/2023
Event Time: 12:00 [EDT]
Last Update Date: 04/11/2023
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
Person (Organization):
Orth, Steve (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Orth, Steve (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MEDICAL EVENT - DOSE RECEIVED GREATER THAN PRESCRIBED
The following information is a synopsis of information provided by the licensee:
This event occurred at Community Health Network, North Hospital on 4/10/2023 and the error was discovered at approximately 12:00 p.m. [EDT].
This procedure involved a split dose, so the patient received two separate doses in two separate locations in the liver. Hospital personnel use a spreadsheet to help with calculations while drawing the dose and to determine the administered activity after the procedure. Hospital personnel had two spreadsheets due to the split dose. When the radiation safety officer (RSO) was completing the worksheets after the procedure, she noticed that the Grays (Gy) delivered on one of the doses was much higher than anticipated. When the RSO reviewed the worksheet, she realized that she had a typo in the prescribed activity in the worksheet and did not catch it prior to administration. Typically, the physician will fill out the written directive with giga-becquerel (GBq) and the RSO would enter millicuries (mCi) in parentheses, since the dose calibrator reads in mCi. Although the worksheet converts dose, this helps as a double check when completing the written directive. In this case, the RSO had not entered mCi, only GBq and did not catch that the second dose was much higher than the prescribed activity. If the RSO had entered the mCi on the written directive (WD) as per usual, she would have caught that this dose was higher than prescribed.
Initial corrective action will be to enter both GBq and mCi on the WD and give both versions of activity when doing the patient identification at the beginning of the procedure with the physician.
The physician was notified immediately and she was notifying the patient. At this time there is not expected to be any detrimental effects to the patient.
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The prescribed first dose was 43.2 mCi of Y-90 SIR-Spheres, 63.2 mCi was delivered. The prescribed second dose was 18.9 mCi and 20.8 mCi was delivered.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information is a synopsis of information provided by the licensee:
This event occurred at Community Health Network, North Hospital on 4/10/2023 and the error was discovered at approximately 12:00 p.m. [EDT].
This procedure involved a split dose, so the patient received two separate doses in two separate locations in the liver. Hospital personnel use a spreadsheet to help with calculations while drawing the dose and to determine the administered activity after the procedure. Hospital personnel had two spreadsheets due to the split dose. When the radiation safety officer (RSO) was completing the worksheets after the procedure, she noticed that the Grays (Gy) delivered on one of the doses was much higher than anticipated. When the RSO reviewed the worksheet, she realized that she had a typo in the prescribed activity in the worksheet and did not catch it prior to administration. Typically, the physician will fill out the written directive with giga-becquerel (GBq) and the RSO would enter millicuries (mCi) in parentheses, since the dose calibrator reads in mCi. Although the worksheet converts dose, this helps as a double check when completing the written directive. In this case, the RSO had not entered mCi, only GBq and did not catch that the second dose was much higher than the prescribed activity. If the RSO had entered the mCi on the written directive (WD) as per usual, she would have caught that this dose was higher than prescribed.
Initial corrective action will be to enter both GBq and mCi on the WD and give both versions of activity when doing the patient identification at the beginning of the procedure with the physician.
The physician was notified immediately and she was notifying the patient. At this time there is not expected to be any detrimental effects to the patient.
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The prescribed first dose was 43.2 mCi of Y-90 SIR-Spheres, 63.2 mCi was delivered. The prescribed second dose was 18.9 mCi and 20.8 mCi was delivered.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Power Reactor
Event Number: 56471
Facility: LaSalle
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: Erik Thompson
HQ OPS Officer: Sam Colvard
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: Erik Thompson
HQ OPS Officer: Sam Colvard
Notification Date: 04/17/2023
Notification Time: 09:37 [ET]
Event Date: 04/17/2023
Event Time: 02:46 [CDT]
Last Update Date: 04/17/2023
Notification Time: 09:37 [ET]
Event Date: 04/17/2023
Event Time: 02:46 [CDT]
Last Update Date: 04/17/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Orth, Steve (R3DO)
Orth, Steve (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
SINGLE TRAIN OF LOW PRESSURE CORE SPRAY INOPERABLE
The following information was provided by the licensee via email:
"At 0246 CDT on April 17, 2023, it was discovered that the single train low pressure core spray system was inoperable. Due to this inoperability, the system was in a condition that could have prevented the fulfillment of a safety function; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v). All other emergency core cooling systems remained operable during this time period.
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
LaSalle Unit 1 is in a 7 day limiting condition for operation.
The following information was provided by the licensee via email:
"At 0246 CDT on April 17, 2023, it was discovered that the single train low pressure core spray system was inoperable. Due to this inoperability, the system was in a condition that could have prevented the fulfillment of a safety function; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v). All other emergency core cooling systems remained operable during this time period.
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
LaSalle Unit 1 is in a 7 day limiting condition for operation.
Agreement State
Event Number: 56382
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Rubino Engineering, Inc.
Region: 3
City: Elgin State: IL
County:
License #: IL-02396-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Ernest West
Licensee: Rubino Engineering, Inc.
Region: 3
City: Elgin State: IL
County:
License #: IL-02396-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Ernest West
Notification Date: 02/24/2023
Notification Time: 09:36 [ET]
Event Date: 02/23/2023
Event Time: 00:00 [CST]
Last Update Date: 04/18/2023
Notification Time: 09:36 [ET]
Event Date: 02/23/2023
Event Time: 00:00 [CST]
Last Update Date: 04/18/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Feliz-Adorno, Nestor (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Feliz-Adorno, Nestor (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 4/19/2023
EN Revision Text: AGREEMENT STATE REPORT - POTENTIALLY DAMAGED GAUGE
The following information was provided by the Illinois Emergency Management Agency (IEMA) via email:
"At 1730 CST on 2/23/2023, the IEMA was contacted by the radiation safety officer (RSO) for Rubino Engineering to advise of a portable moisture/density gauge involved in an accident at a temporary jobsite. Reportedly, a Troxler 3400 series gauge was in use at a construction site in Maple Park, IL when it rolled down an embankment and was struck by a skid steer. The licensee's technician remained on scene and assessed minor damage to the case. The source rod was not extended at the time of the accident. Both sources were reported as intact and the area secured until the RSO could arrive within an hour with a survey meter. No exposure concerns were reported or anticipated. The RSO arrived on site approximately an hour later to assess, survey, package, and return the device to safe storage. The IEMA advised that they were available to respond if contamination was suspected or if there were complications in retrieving and returning the sources to storage. At approximately 1900, the RSO advised IEMA that the device had been returned to storage. Surveys of the device and source holders were consistent with an undamaged device.
"On 2/24/2023, IEMA inspectors initiated a reactionary inspection to verify the presence of both sources, assess for removeable contamination, advise on proper return of the unit to the manufacturer, determine root cause of the incident and evaluate compliance with IEMA regulations. Updates from that inspection, as well as specifics on the device serial number and sources will be provided once available."
Illinois Item Number: IL230005
* * * UPDATE ON 4/18/23 AT 1326 EDT FROM IEMA TO SAM COLVARD* * *
"On 2/24/23, IEMA inspectors performed a reactionary inspection and verified the presence of both sources. An assessment for removeable contamination was performed with negative results. Inspectors advised on the proper return of the unit to the manufacturer and verified the package TI [Transport Index]. No items of non-compliance were identified as the licensee met license and regulatory requirements. The root cause was determined as ill-advised placement of the gauge on filter fabric (near the edge of a hill) which got pulled by a skid steer while backing at the bottom of the hill causing the gauge to tumble down the hill in the path of the backing skid steer.
"The licensee advised that corrective actions included advising gauge users regarding placement of gauges near any edge while at a field site and discussion on modification of field use procedures to place the gauge back in the transport container during lapses between testing.
"This matter may be considered closed pending satisfactory sealed source leak test results from the manufacturer upon return of the gauge to Troxler and the licensee's required written report per 340.1230(b)."
Notified R3DO (ORTH), and NMSS Events Notification (E-mail).
EN Revision Text: AGREEMENT STATE REPORT - POTENTIALLY DAMAGED GAUGE
The following information was provided by the Illinois Emergency Management Agency (IEMA) via email:
"At 1730 CST on 2/23/2023, the IEMA was contacted by the radiation safety officer (RSO) for Rubino Engineering to advise of a portable moisture/density gauge involved in an accident at a temporary jobsite. Reportedly, a Troxler 3400 series gauge was in use at a construction site in Maple Park, IL when it rolled down an embankment and was struck by a skid steer. The licensee's technician remained on scene and assessed minor damage to the case. The source rod was not extended at the time of the accident. Both sources were reported as intact and the area secured until the RSO could arrive within an hour with a survey meter. No exposure concerns were reported or anticipated. The RSO arrived on site approximately an hour later to assess, survey, package, and return the device to safe storage. The IEMA advised that they were available to respond if contamination was suspected or if there were complications in retrieving and returning the sources to storage. At approximately 1900, the RSO advised IEMA that the device had been returned to storage. Surveys of the device and source holders were consistent with an undamaged device.
"On 2/24/2023, IEMA inspectors initiated a reactionary inspection to verify the presence of both sources, assess for removeable contamination, advise on proper return of the unit to the manufacturer, determine root cause of the incident and evaluate compliance with IEMA regulations. Updates from that inspection, as well as specifics on the device serial number and sources will be provided once available."
Illinois Item Number: IL230005
* * * UPDATE ON 4/18/23 AT 1326 EDT FROM IEMA TO SAM COLVARD* * *
"On 2/24/23, IEMA inspectors performed a reactionary inspection and verified the presence of both sources. An assessment for removeable contamination was performed with negative results. Inspectors advised on the proper return of the unit to the manufacturer and verified the package TI [Transport Index]. No items of non-compliance were identified as the licensee met license and regulatory requirements. The root cause was determined as ill-advised placement of the gauge on filter fabric (near the edge of a hill) which got pulled by a skid steer while backing at the bottom of the hill causing the gauge to tumble down the hill in the path of the backing skid steer.
"The licensee advised that corrective actions included advising gauge users regarding placement of gauges near any edge while at a field site and discussion on modification of field use procedures to place the gauge back in the transport container during lapses between testing.
"This matter may be considered closed pending satisfactory sealed source leak test results from the manufacturer upon return of the gauge to Troxler and the licensee's required written report per 340.1230(b)."
Notified R3DO (ORTH), and NMSS Events Notification (E-mail).
Agreement State
Event Number: 56418
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: G.E. Healthcare DBA/ Medi+Physics
Region: 3
City: Arlington Heights State: IL
County:
License #: IL-01109-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Ernest West
Licensee: G.E. Healthcare DBA/ Medi+Physics
Region: 3
City: Arlington Heights State: IL
County:
License #: IL-01109-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Ernest West
Notification Date: 03/17/2023
Notification Time: 14:57 [ET]
Event Date: 03/08/2023
Event Time: 22:47 [CDT]
Last Update Date: 04/18/2023
Notification Time: 14:57 [ET]
Event Date: 03/08/2023
Event Time: 22:47 [CDT]
Last Update Date: 04/18/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 4/19/2023
EN Revision Text: AGREEMENT STATE REPORT - LOST PACKAGES
The following information was provided by the Illinois Emergency Management Agency (the Agency) via email:
"The Agency [Illinois Emergency Management Agency] was notified the evening of 3/16/23 by General Electric (GE) Healthcare in Arlington Heights, IL to advise of two radiopharmaceutical packages that were missing in transit. The last known location was the carrier hub in Memphis, TN. The carrier has advised efforts to locate the packages have ceased and both have been declared as lost. These packages do not represent a significant public safety hazard and there are no indications of intentional theft or diversion. TN and TX program officials have been notified as well. Additional details will be provided as they become available. This matter has a 30-day reporting requirement to the NRC [Nuclear Regulatory Commission] with a required call to the NRC Headquarters Operations Officer (HOO). Details on the packages are as follows:
"Package 1:
[The package] shipped 3/8/23 to Doctor's Hospital at Renaissance in Edinburg, TX. [The package] contained (1) 10mL shielded vial of I-123. Package activity at the time of shipment was 14.3 mCi. [The package contains] 0.0002 mCi of activity as of 3/17/2022 at 1500 EDT. The last scan occurred 2247 CDT on 3/8/23. GE Healthcare contacted the customer and confirmed that the package was not received.
"Package 2:
[The package] shipped 3/10/23 to Panhandle Nuclear in Amarillo, TX. [The package] contained (1) 10mL shielded vial of In-111. Package activity at the time of shipment was 3.2 mCi. [The package contains] 0.585 mCi of activity as of 3/17/2022 at 1500 EDT. The last scan occurred 0009 CDT on 3/11/23. GE Healthcare contacted the customer and confirmed that the package was not received."
IL Event Number: IL230007
* * * UPDATE ON 04/18/23 AT 1220 EDT FROM GARY FORSEE TO JOHN RUSSELL * * *
"As of 4/17/2023 the packages remain lost. No additional information has been provided by the carrier. The packages have decayed to background and do not represent a public safety hazard. This report will be updated with any new information but is otherwise considered closed."
Notified R3DO (Orth), NMSS Events Notification, and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST PACKAGES
The following information was provided by the Illinois Emergency Management Agency (the Agency) via email:
"The Agency [Illinois Emergency Management Agency] was notified the evening of 3/16/23 by General Electric (GE) Healthcare in Arlington Heights, IL to advise of two radiopharmaceutical packages that were missing in transit. The last known location was the carrier hub in Memphis, TN. The carrier has advised efforts to locate the packages have ceased and both have been declared as lost. These packages do not represent a significant public safety hazard and there are no indications of intentional theft or diversion. TN and TX program officials have been notified as well. Additional details will be provided as they become available. This matter has a 30-day reporting requirement to the NRC [Nuclear Regulatory Commission] with a required call to the NRC Headquarters Operations Officer (HOO). Details on the packages are as follows:
"Package 1:
[The package] shipped 3/8/23 to Doctor's Hospital at Renaissance in Edinburg, TX. [The package] contained (1) 10mL shielded vial of I-123. Package activity at the time of shipment was 14.3 mCi. [The package contains] 0.0002 mCi of activity as of 3/17/2022 at 1500 EDT. The last scan occurred 2247 CDT on 3/8/23. GE Healthcare contacted the customer and confirmed that the package was not received.
"Package 2:
[The package] shipped 3/10/23 to Panhandle Nuclear in Amarillo, TX. [The package] contained (1) 10mL shielded vial of In-111. Package activity at the time of shipment was 3.2 mCi. [The package contains] 0.585 mCi of activity as of 3/17/2022 at 1500 EDT. The last scan occurred 0009 CDT on 3/11/23. GE Healthcare contacted the customer and confirmed that the package was not received."
IL Event Number: IL230007
* * * UPDATE ON 04/18/23 AT 1220 EDT FROM GARY FORSEE TO JOHN RUSSELL * * *
"As of 4/17/2023 the packages remain lost. No additional information has been provided by the carrier. The packages have decayed to background and do not represent a public safety hazard. This report will be updated with any new information but is otherwise considered closed."
Notified R3DO (Orth), NMSS Events Notification, and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56419
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: G.E. Healthcare DBA/ Medi+Physics
Region: 3
City: Arlington Heights State: IL
County:
License #: IL-01109-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Ernest West
Licensee: G.E. Healthcare DBA/ Medi+Physics
Region: 3
City: Arlington Heights State: IL
County:
License #: IL-01109-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Ernest West
Notification Date: 03/17/2023
Notification Time: 16:47 [ET]
Event Date: 03/11/2023
Event Time: 00:09 [CDT]
Last Update Date: 04/18/2023
Notification Time: 16:47 [ET]
Event Date: 03/11/2023
Event Time: 00:09 [CDT]
Last Update Date: 04/18/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 4/19/2023
EN Revision Text: AGREEMENT STATE REPORT - LOST PACKAGES
The following information was provided by the Illinois Emergency Management Agency (the Agency) via email:
"Shortly after reporting the first two missing packages (see EN56418), the Agency was contacted on 3/17/23 by General Electric (GE) Healthcare in Arlington Heights, IL to advise of a third radiopharmaceutical package that went missing in transit. The last known location was the carrier hub in Memphis, TN. The carrier has advised efforts to locate the packages have ceased and the package was declared as lost. This package does not represent a significant public safety hazard and there is no indication of intentional theft or diversion. TN and AL program officials were notified. Details are provided below.
"Package Details:
[The package] shipped on 3/10/23 to Cardinal Health in Birmingham, AL. [The package] contained (1) 10mL shielded vial of In-111. Package activity at the time of shipment was 3.2 mCi. [The package] contains 0.563 mCi [as of 3/17/2023, 1647 EDT]. The last scan occurred at 0009 CDT on 3/11/23. GE Healthcare contacted the customer and confirmed that the package was not received.
"Additional details will be provided as they become available. This matter has a 30-day reporting requirement to the NRC with a required call to the NRC Headquarters Operations Officer."
IL Event Number: IL230008
* * * UPDATE ON 04/18/23 AT 1220 EDT FROM GARY FORSEE TO JOHN RUSSELL * * *
"As of 4/17/23 the packages remain lost. No additional information has been provided by the carrier. The packages have decayed to background and do not represent a public safety hazard. This report will be updated with any new information but is otherwise considered closed."
Notified R3DO (Orth), NMSS Events Notification, and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-
pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST PACKAGES
The following information was provided by the Illinois Emergency Management Agency (the Agency) via email:
"Shortly after reporting the first two missing packages (see EN56418), the Agency was contacted on 3/17/23 by General Electric (GE) Healthcare in Arlington Heights, IL to advise of a third radiopharmaceutical package that went missing in transit. The last known location was the carrier hub in Memphis, TN. The carrier has advised efforts to locate the packages have ceased and the package was declared as lost. This package does not represent a significant public safety hazard and there is no indication of intentional theft or diversion. TN and AL program officials were notified. Details are provided below.
"Package Details:
[The package] shipped on 3/10/23 to Cardinal Health in Birmingham, AL. [The package] contained (1) 10mL shielded vial of In-111. Package activity at the time of shipment was 3.2 mCi. [The package] contains 0.563 mCi [as of 3/17/2023, 1647 EDT]. The last scan occurred at 0009 CDT on 3/11/23. GE Healthcare contacted the customer and confirmed that the package was not received.
"Additional details will be provided as they become available. This matter has a 30-day reporting requirement to the NRC with a required call to the NRC Headquarters Operations Officer."
IL Event Number: IL230008
* * * UPDATE ON 04/18/23 AT 1220 EDT FROM GARY FORSEE TO JOHN RUSSELL * * *
"As of 4/17/23 the packages remain lost. No additional information has been provided by the carrier. The packages have decayed to background and do not represent a public safety hazard. This report will be updated with any new information but is otherwise considered closed."
Notified R3DO (Orth), NMSS Events Notification, and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-
pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56465
Rep Org: Ohio Bureau of Radiation Protection
Licensee: Anheuser Busch (GL)
Region: 3
City: Columbus State: OH
County:
License #: 00006GL0046
Agreement: Y
Docket:
NRC Notified By: Stephen James
HQ OPS Officer: Thomas Herrity
Licensee: Anheuser Busch (GL)
Region: 3
City: Columbus State: OH
County:
License #: 00006GL0046
Agreement: Y
Docket:
NRC Notified By: Stephen James
HQ OPS Officer: Thomas Herrity
Notification Date: 04/12/2023
Notification Time: 11:27 [ET]
Event Date: 03/03/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/12/2023
Notification Time: 11:27 [ET]
Event Date: 03/03/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/12/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Orth, Steve (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Orth, Steve (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK OPEN SHUTTER (REPAIRED)
The following information was provided by the Ohio Department of Health via email:
"On 3/3/23, the general licensee discovered a generally licensed device [used for package content measuring] with a failing source shutter, or the 'open-close' mechanism, was likely failing in the open position during scheduled internal routine inspection. The receiver portion of the device demonstrated radiation readings were present in the bridge opening when the shutter should have be closed and reading no presence.
"The manufacturer was contacted and the device was taken out of service per the manufacturer's advice regarding the regulations. On 3/21/23, the manufacturer arrived on site, repaired the shutter device, and conducted a survey of the device to ensure the shutter was closing properly after repairing. The survey after the repairs, showed that even with the shutter open, outside the direct beam, annual radiation levels would be less than 100 mrem per year.
Device Manufacturer: Heuft
Device Model: 45US
Device Serial Number: 9KG005979
Source Model: AMC.25
Source Serial Number: 2097LQ containing 40 mCi of Am-241 assayed 3/28/2000
"Note: Initial report made on 4/7/23, by manufacturer to Illinois Agreement State program which passed along to Ohio program. When contacted by Ohio on 4/11/23, the general licensee expressed they were unaware of the requirement to report. General licensee was instructed as to the requirements and they submitted report on 4/12/23."
Ohio Event Item Number: OH230006
The following information was provided by the Ohio Department of Health via email:
"On 3/3/23, the general licensee discovered a generally licensed device [used for package content measuring] with a failing source shutter, or the 'open-close' mechanism, was likely failing in the open position during scheduled internal routine inspection. The receiver portion of the device demonstrated radiation readings were present in the bridge opening when the shutter should have be closed and reading no presence.
"The manufacturer was contacted and the device was taken out of service per the manufacturer's advice regarding the regulations. On 3/21/23, the manufacturer arrived on site, repaired the shutter device, and conducted a survey of the device to ensure the shutter was closing properly after repairing. The survey after the repairs, showed that even with the shutter open, outside the direct beam, annual radiation levels would be less than 100 mrem per year.
Device Manufacturer: Heuft
Device Model: 45US
Device Serial Number: 9KG005979
Source Model: AMC.25
Source Serial Number: 2097LQ containing 40 mCi of Am-241 assayed 3/28/2000
"Note: Initial report made on 4/7/23, by manufacturer to Illinois Agreement State program which passed along to Ohio program. When contacted by Ohio on 4/11/23, the general licensee expressed they were unaware of the requirement to report. General licensee was instructed as to the requirements and they submitted report on 4/12/23."
Ohio Event Item Number: OH230006
Power Reactor
Event Number: 56474
Facility: Turkey Point
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Jose Vasquez
HQ OPS Officer: Bill Gott
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Jose Vasquez
HQ OPS Officer: Bill Gott
Notification Date: 04/18/2023
Notification Time: 03:56 [ET]
Event Date: 04/15/2023
Event Time: 11:12 [EDT]
Last Update Date: 04/18/2023
Notification Time: 03:56 [ET]
Event Date: 04/15/2023
Event Time: 11:12 [EDT]
Last Update Date: 04/18/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
Miller, Mark (R2DO)
Miller, Mark (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | N | 0 | Refueling | 0 | Refueling |
RCS PRESSURE BOUNDARY DEGRADED
The following information was provided by the licensee via email:
"At 1112 EDT on 4/15/23, it was determined that the [reactor coolant system] RCS pressure boundary does not meet ASME Section XI, Table IWB-341 0-1, `Acceptable Standards,' due to through wall leak of the flux mapper seal table guide tube H-6. Corrective actions have been scheduled. `This event is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(A).
"A follow-up review of the condition revealed that 10 CFR 50.72 notification was applicable within 8 hours of the time of discovery on 04/15/23.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"At 1112 EDT on 4/15/23, it was determined that the [reactor coolant system] RCS pressure boundary does not meet ASME Section XI, Table IWB-341 0-1, `Acceptable Standards,' due to through wall leak of the flux mapper seal table guide tube H-6. Corrective actions have been scheduled. `This event is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(A).
"A follow-up review of the condition revealed that 10 CFR 50.72 notification was applicable within 8 hours of the time of discovery on 04/15/23.
"The NRC Resident Inspector has been notified."