Event Notification Report for December 13, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/12/2021 - 12/13/2021
Fuel Cycle Facility
Event Number: 55623
Facility: Global Nuclear Fuel - Americas
Region: 2 State: NC
Unit: [] [] []
RX Type: Uranium Fuel Fabrication
Comments: Leu Conversion (Uf6 To Uo2)
Leu Fabrication
Lwr Commerical Fuel
NRC Notified By: Phillip Ollis
HQ OPS Officer: Kerby Scales
Region: 2 State: NC
Unit: [] [] []
RX Type: Uranium Fuel Fabrication
Comments: Leu Conversion (Uf6 To Uo2)
Leu Fabrication
Lwr Commerical Fuel
NRC Notified By: Phillip Ollis
HQ OPS Officer: Kerby Scales
Notification Date: 12/03/2021
Notification Time: 13:58 [ET]
Event Date: 12/02/2021
Event Time: 18:26 [EST]
Last Update Date: 12/03/2021
Notification Time: 13:58 [ET]
Event Date: 12/02/2021
Event Time: 18:26 [EST]
Last Update Date: 12/03/2021
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (c) - Offsite Notification/News Rel
10 CFR Section:
PART 70 APP A (c) - Offsite Notification/News Rel
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Miller, Mark (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Miller, Mark (R2DO)
EN Revision Imported Date: 12/13/2021
EN Revision Text: OFFSITE NOTIFICATION
"At approximately 1826 EST on December 2, the New Hanover County Deputy Fire Marshall was notified that a roll up fire door located between a boiler room and the radioactive waste system malfunctioned in the open position. Compensatory measures were discussed with the Deputy Fire Marshall and then implemented. The door was manually closed at approximately 1350, December 3. Because the New Hanover County Deputy Fire Marshall was notified, a concurrent notification to the NRC Operations Center is being made per 10 CFR 70, Appendix A(c)."
The licensee will notify the State and NRC Region II.
EN Revision Text: OFFSITE NOTIFICATION
"At approximately 1826 EST on December 2, the New Hanover County Deputy Fire Marshall was notified that a roll up fire door located between a boiler room and the radioactive waste system malfunctioned in the open position. Compensatory measures were discussed with the Deputy Fire Marshall and then implemented. The door was manually closed at approximately 1350, December 3. Because the New Hanover County Deputy Fire Marshall was notified, a concurrent notification to the NRC Operations Center is being made per 10 CFR 70, Appendix A(c)."
The licensee will notify the State and NRC Region II.
Non-Agreement State
Event Number: 55624
Rep Org: Trijicon
Licensee: Trijicon
Region: 3
City: Wixom State: MI
County:
License #: 21-19874-01
Agreement: N
Docket:
NRC Notified By: Paul Koesler
HQ OPS Officer: Kerby Scales
Licensee: Trijicon
Region: 3
City: Wixom State: MI
County:
License #: 21-19874-01
Agreement: N
Docket:
NRC Notified By: Paul Koesler
HQ OPS Officer: Kerby Scales
Notification Date: 12/03/2021
Notification Time: 15:33 [ET]
Event Date: 12/02/2021
Event Time: 00:00 [CST]
Last Update Date: 12/03/2021
Notification Time: 15:33 [ET]
Event Date: 12/02/2021
Event Time: 00:00 [CST]
Last Update Date: 12/03/2021
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(ii) - Lost/Stolen LNM>10x
10 CFR Section:
20.2201(a)(1)(ii) - Lost/Stolen LNM>10x
Person (Organization):
Stoedter, Karla (R3)
NMSS_Events_Notification, (EMAIL)
ILTAB, (EMAIL)
Heller, James (R3)
Stoedter, Karla (R3)
NMSS_Events_Notification, (EMAIL)
ILTAB, (EMAIL)
Heller, James (R3)
EN Revision Imported Date: 12/13/2021
EN Revision Text: STOLEN / RECOVERED RADIOACTIVE MATERIAL
The following is a summary of a phone call with the Radiation Safety Officer (RSO) at Trijicon (licensee):
On December 2, 2021, the RSO was contacted by the FBI regarding scrap bags of radioactive material discovered in a raid that belong to the licensee. The FBI sent the licensee pictures of the material. The licensee believes the combined scrap bags of radioactive material contains 100 Curies of Tritium. The dates on the bags are from 2012 to 2017. The RSO is unsure how long the scrap bags of material have been missing. The licensee notified the NRC Region III Office.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: STOLEN / RECOVERED RADIOACTIVE MATERIAL
The following is a summary of a phone call with the Radiation Safety Officer (RSO) at Trijicon (licensee):
On December 2, 2021, the RSO was contacted by the FBI regarding scrap bags of radioactive material discovered in a raid that belong to the licensee. The FBI sent the licensee pictures of the material. The licensee believes the combined scrap bags of radioactive material contains 100 Curies of Tritium. The dates on the bags are from 2012 to 2017. The RSO is unsure how long the scrap bags of material have been missing. The licensee notified the NRC Region III Office.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Non-Agreement State
Event Number: 55625
Rep Org: Jacobi Geotechnical Engineering
Licensee: Jacobi Geotechnical Engineering
Region: 3
City: Ofallon State: MO
County:
License #: 2432231-01
Agreement: N
Docket:
NRC Notified By: Jared Holland
HQ OPS Officer: Kerby Scales
Licensee: Jacobi Geotechnical Engineering
Region: 3
City: Ofallon State: MO
County:
License #: 2432231-01
Agreement: N
Docket:
NRC Notified By: Jared Holland
HQ OPS Officer: Kerby Scales
Notification Date: 12/03/2021
Notification Time: 15:55 [ET]
Event Date: 12/03/2021
Event Time: 00:00 [CST]
Last Update Date: 12/03/2021
Notification Time: 15:55 [ET]
Event Date: 12/03/2021
Event Time: 00:00 [CST]
Last Update Date: 12/03/2021
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Stoedter, Karla (R3)
NMSS_Events_Notification, (EMAIL)
Stoedter, Karla (R3)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 12/13/2021
EN Revision Text: DAMAGED DENSITY GAUGE
The following is a summary of a phone call with Jacobi Geotechnical Engineering (licensee):
On December 3, 2021, while on a jobsite in St. Peters, MO, the licensee's Humbolt 5001EZ density gauge was run over. The source rod was broken, but remained secured in the case. The Humbolt gauge serial number is 3141 and contains 10 mCi of Cs-137 and 40 mCi Am-241/Be.
The licensee requested assistance to secure and dispose the gauge. The gauge was secured and packaged in a transportation box. No overexposures were reported.
EN Revision Text: DAMAGED DENSITY GAUGE
The following is a summary of a phone call with Jacobi Geotechnical Engineering (licensee):
On December 3, 2021, while on a jobsite in St. Peters, MO, the licensee's Humbolt 5001EZ density gauge was run over. The source rod was broken, but remained secured in the case. The Humbolt gauge serial number is 3141 and contains 10 mCi of Cs-137 and 40 mCi Am-241/Be.
The licensee requested assistance to secure and dispose the gauge. The gauge was secured and packaged in a transportation box. No overexposures were reported.
Agreement State
Event Number: 55628
Rep Org: MA Radiation Control Program
Licensee: Amherst College
Region: 1
City: Amherst State: MA
County:
License #: 03-5707
Agreement: Y
Docket:
NRC Notified By: Szymon Mudrewicz
HQ OPS Officer: Mike Stafford
Licensee: Amherst College
Region: 1
City: Amherst State: MA
County:
License #: 03-5707
Agreement: Y
Docket:
NRC Notified By: Szymon Mudrewicz
HQ OPS Officer: Mike Stafford
Notification Date: 12/06/2021
Notification Time: 18:30 [ET]
Event Date: 12/06/2021
Event Time: 14:35 [EST]
Last Update Date: 12/06/2021
Notification Time: 18:30 [ET]
Event Date: 12/06/2021
Event Time: 14:35 [EST]
Last Update Date: 12/06/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Dentel, Glenn (R1)
NMSS_Events_Notification, (EMAIL)
Dentel, Glenn (R1)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 12/14/2021
EN Revision Text: AGREEMENT STATE - LEAKING SEALED SOURCE
The following was received from the Massachusetts Radiation Control Program (the Agency) via email:
"On December 6, 2021 at 1435 EST the Massachusetts Radiation Control Program received a call from the [Radiation Safety Officer] RSO at Amherst College reporting a leaking sealed source. The source is an open-window reference source (RM Corp, s/n R8023) containing 0.001 milliCi of Am-241 and the RSO believes he accidentally wiped the window while collecting the leak test sample of the source, the analysis of which showed 0.0908 microCi of removable activity which is in excess of regulatory limits. The RSO collected the leak test sample on November 29, 2021 at 0930 EST and sent it the same day to RSCS, Inc. for analysis. The leak test results were transmitted to the RSO by email on December 2, 2021 but the RSO was on vacation from December 2 through December 3 and was unable to review the email. The RSO was back at work on December 6, 2021 and reviewed the email at 1230 EST due to previous work commitments in the morning. The area where the source was handled was surveyed and no contamination was found. The RSO assumes the source window was damaged due to being wiped therefore the source will be secured and properly disposed of in accordance with the regulations.
"The Agency considers this event open."
Massachusetts Event Number: TBD
EN Revision Text: AGREEMENT STATE - LEAKING SEALED SOURCE
The following was received from the Massachusetts Radiation Control Program (the Agency) via email:
"On December 6, 2021 at 1435 EST the Massachusetts Radiation Control Program received a call from the [Radiation Safety Officer] RSO at Amherst College reporting a leaking sealed source. The source is an open-window reference source (RM Corp, s/n R8023) containing 0.001 milliCi of Am-241 and the RSO believes he accidentally wiped the window while collecting the leak test sample of the source, the analysis of which showed 0.0908 microCi of removable activity which is in excess of regulatory limits. The RSO collected the leak test sample on November 29, 2021 at 0930 EST and sent it the same day to RSCS, Inc. for analysis. The leak test results were transmitted to the RSO by email on December 2, 2021 but the RSO was on vacation from December 2 through December 3 and was unable to review the email. The RSO was back at work on December 6, 2021 and reviewed the email at 1230 EST due to previous work commitments in the morning. The area where the source was handled was surveyed and no contamination was found. The RSO assumes the source window was damaged due to being wiped therefore the source will be secured and properly disposed of in accordance with the regulations.
"The Agency considers this event open."
Massachusetts Event Number: TBD
Fuel Cycle Facility
Event Number: 55634
Facility: Framatome ANP Richland
Region: 2 State: WA
Unit: [] [] []
RX Type: Uranium Fuel Fabrication
Comments: Leu Conversion
Fabrication & Scrap Recovery
Commercial Lwr Fuel
NRC Notified By: Calvin Manning
HQ OPS Officer: Bethany Cecere
Region: 2 State: WA
Unit: [] [] []
RX Type: Uranium Fuel Fabrication
Comments: Leu Conversion
Fabrication & Scrap Recovery
Commercial Lwr Fuel
NRC Notified By: Calvin Manning
HQ OPS Officer: Bethany Cecere
Notification Date: 12/09/2021
Notification Time: 10:00 [ET]
Event Date: 12/08/2021
Event Time: 07:45 [PST]
Last Update Date: 12/09/2021
Notification Time: 10:00 [ET]
Event Date: 12/08/2021
Event Time: 07:45 [PST]
Last Update Date: 12/09/2021
Emergency Class: Non Emergency
10 CFR Section:
70.50(b)(3) - Med Treat Involving Contam
10 CFR Section:
70.50(b)(3) - Med Treat Involving Contam
Person (Organization):
Miller, Mark (R2DO)
NMSS_Events_Notification, (EMAIL)
Miller, Mark (R2DO)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 12/13/2021
EN Revision Text: UNPLANNED MEDICAL TREATMENT OF A CONTAMINATED WORKER
"On December 8, 2021 at approximately 0745 PST, an instrument technician was contaminated with uranyl nitrate solution while working on process instrumentation [calibrating a pressure transmitter in the Scrap Uranium Recovery Facility]. The individual followed safety protocol by utilizing the emergency wash station and as a precaution was sent for medical evaluation [at Kadlec Regional Medical Center] due to skin exposure to nitric acid.
"Prior to leaving the site, Framatome Health and Safety Technicians decontaminated the individual to below release limits with the exception of their hands. The individual's hands were placed inside gloves which were secured to their wrists prior to being transported. The worker was transported to an offsite medical facility accompanied by plant health physics personnel.
"After being evaluated, the individual returned to Framatome where their hands were decontaminated to below release limits and returned to work. The process area where this work was being performed was cleaned and the equipment was secured. The event has been entered into the facility's corrective action system.
"Framatome is reporting this event consistent with the requirements of 10 CFR 70.50(b)(3)."
The licensee notified the Washington Department of Health and the NRC R2 Project Manager (Vukovinsky).
EN Revision Text: UNPLANNED MEDICAL TREATMENT OF A CONTAMINATED WORKER
"On December 8, 2021 at approximately 0745 PST, an instrument technician was contaminated with uranyl nitrate solution while working on process instrumentation [calibrating a pressure transmitter in the Scrap Uranium Recovery Facility]. The individual followed safety protocol by utilizing the emergency wash station and as a precaution was sent for medical evaluation [at Kadlec Regional Medical Center] due to skin exposure to nitric acid.
"Prior to leaving the site, Framatome Health and Safety Technicians decontaminated the individual to below release limits with the exception of their hands. The individual's hands were placed inside gloves which were secured to their wrists prior to being transported. The worker was transported to an offsite medical facility accompanied by plant health physics personnel.
"After being evaluated, the individual returned to Framatome where their hands were decontaminated to below release limits and returned to work. The process area where this work was being performed was cleaned and the equipment was secured. The event has been entered into the facility's corrective action system.
"Framatome is reporting this event consistent with the requirements of 10 CFR 70.50(b)(3)."
The licensee notified the Washington Department of Health and the NRC R2 Project Manager (Vukovinsky).
Power Reactor
Event Number: 55638
Facility: Oconee
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: Brian Morris
HQ OPS Officer: Howie Crouch
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: Brian Morris
HQ OPS Officer: Howie Crouch
Notification Date: 12/10/2021
Notification Time: 03:54 [ET]
Event Date: 12/10/2021
Event Time: 00:49 [EST]
Last Update Date: 12/10/2021
Notification Time: 03:54 [ET]
Event Date: 12/10/2021
Event Time: 00:49 [EST]
Last Update Date: 12/10/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Miller, Mark (R2)
Miller, Mark (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | A/R | Y | 73 | Power Operation | 0 | Hot Standby |
EN Revision Imported Date: 12/13/2021
EN Revision Text: AUTOMATIC REACTOR TRIP
"At 0049 EST, on December 10, 2021, with Unit 2 in Mode 1 at 73 percent power, the reactor automatically tripped due to an unknown condition. The trip was not complex, with all systems responding normally post-trip.
"Operations responded and stabilized the plant. Decay heat is being maintained by discharge steam to the main condenser using the turbine bypass valves. Units 1 and 3 are not affected. The cause of the trip is under investigation.
"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)iv)(B).
"There was no impact to the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
All rods inserted into the core during the trip. The plant is in its normal shutdown electrical lineup maintaining normal operating pressure and temperature.
EN Revision Text: AUTOMATIC REACTOR TRIP
"At 0049 EST, on December 10, 2021, with Unit 2 in Mode 1 at 73 percent power, the reactor automatically tripped due to an unknown condition. The trip was not complex, with all systems responding normally post-trip.
"Operations responded and stabilized the plant. Decay heat is being maintained by discharge steam to the main condenser using the turbine bypass valves. Units 1 and 3 are not affected. The cause of the trip is under investigation.
"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)iv)(B).
"There was no impact to the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
All rods inserted into the core during the trip. The plant is in its normal shutdown electrical lineup maintaining normal operating pressure and temperature.
Power Reactor
Event Number: 55641
Facility: Saint Lucie
Region: 2 State: FL
Unit: [1] [] []
RX Type: [1] CE,[2] CE
NRC Notified By: Wess Rexrode
HQ OPS Officer: Lloyd Desotell
Region: 2 State: FL
Unit: [1] [] []
RX Type: [1] CE,[2] CE
NRC Notified By: Wess Rexrode
HQ OPS Officer: Lloyd Desotell
Notification Date: 12/10/2021
Notification Time: 13:35 [ET]
Event Date: 12/10/2021
Event Time: 10:24 [EST]
Last Update Date: 12/10/2021
Notification Time: 13:35 [ET]
Event Date: 12/10/2021
Event Time: 10:24 [EST]
Last Update Date: 12/10/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Miller, Mark (R2)
Miller, Mark (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 100 | Power Operation | 0 | Hot Standby |
MANUAL REACTOR TRIP
"On 12/10/2021, at 1024 EST, with Unit 1 at 100 percent power, the reactor was manually tripped due to lowering level in the steam generators. All systems responded as expected following the trip. The reactor is currently stable in Mode 3 and operators restored steam generator level utilizing main feedwater. The cause of the reduction in feedwater flow is under investigation.
"St. Lucie Unit 2 was not affected and remains at 100 percent power.
"This event is being reported pursuant to 10 CFR 50.72(b)(2)(iv)(B) for the reactor trip.
"The NRC Resident Inspector has been notified."
All rods inserted into the core during the trip. The plant is in its normal shutdown electrical lineup. Decay heat is being maintained by steam discharge to the main condenser using the turbine bypass valves.
"On 12/10/2021, at 1024 EST, with Unit 1 at 100 percent power, the reactor was manually tripped due to lowering level in the steam generators. All systems responded as expected following the trip. The reactor is currently stable in Mode 3 and operators restored steam generator level utilizing main feedwater. The cause of the reduction in feedwater flow is under investigation.
"St. Lucie Unit 2 was not affected and remains at 100 percent power.
"This event is being reported pursuant to 10 CFR 50.72(b)(2)(iv)(B) for the reactor trip.
"The NRC Resident Inspector has been notified."
All rods inserted into the core during the trip. The plant is in its normal shutdown electrical lineup. Decay heat is being maintained by steam discharge to the main condenser using the turbine bypass valves.
Agreement State
Event Number: 55226
Rep Org: ALABAMA RADIATION CONTROL
Licensee: Georgia-Pacific
Region: 1
City: Pennington State: AL
County:
License #: 299
Agreement: Y
Docket:
NRC Notified By: Myron K. Riley
HQ OPS Officer: Lloyd Desotell
Licensee: Georgia-Pacific
Region: 1
City: Pennington State: AL
County:
License #: 299
Agreement: Y
Docket:
NRC Notified By: Myron K. Riley
HQ OPS Officer: Lloyd Desotell
Notification Date: 04/30/2021
Notification Time: 15:41 [ET]
Event Date: 04/30/2021
Event Time: 00:00 [CDT]
Last Update Date: 12/13/2021
Notification Time: 15:41 [ET]
Event Date: 04/30/2021
Event Time: 00:00 [CDT]
Last Update Date: 12/13/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
SCHROEDER, DAN (R1DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
SCHROEDER, DAN (R1DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 12/14/2021
EN Revision Text: AGREEMENT STATE REPORT - STUCK GAUGE SHUTTER
The following information was received from the Alabama Department of Public Health, Office of Radiation Control via email:
"The Radiation Safety Officer for Georgia-Pacific of Pennington, Alabama notified the Alabama Office of Radiation Control that while performing routine six (6) month leak testing and shutter checks, one of their gauges had a shutter stuck in the open position. The manufacturer has been notified and a repair date is pending. Further information involving the gauge is forthcoming in the written report."
Alabama Event No: 21-14
* * * UPDATE FROM CASON COAN TO LLOYD DESOTELL AT 1358 EST ON 12/13/21 * * *
The license number and following gauge information was received via e-mail:
Gauge Manufacturer: Berthold
Model No.: PB 80
Serial No.: 1028/3-10-17
Source: Co-60 (3.081 mCi)
The damaged gauge was transferred off-site for disposal on 10/19/21.
The Alabama Department of Public Health, Office of Radiation Control considers this event closed.
Notified R1DO (Young) and NMSS Events Notification group via email.
EN Revision Text: AGREEMENT STATE REPORT - STUCK GAUGE SHUTTER
The following information was received from the Alabama Department of Public Health, Office of Radiation Control via email:
"The Radiation Safety Officer for Georgia-Pacific of Pennington, Alabama notified the Alabama Office of Radiation Control that while performing routine six (6) month leak testing and shutter checks, one of their gauges had a shutter stuck in the open position. The manufacturer has been notified and a repair date is pending. Further information involving the gauge is forthcoming in the written report."
Alabama Event No: 21-14
* * * UPDATE FROM CASON COAN TO LLOYD DESOTELL AT 1358 EST ON 12/13/21 * * *
The license number and following gauge information was received via e-mail:
Gauge Manufacturer: Berthold
Model No.: PB 80
Serial No.: 1028/3-10-17
Source: Co-60 (3.081 mCi)
The damaged gauge was transferred off-site for disposal on 10/19/21.
The Alabama Department of Public Health, Office of Radiation Control considers this event closed.
Notified R1DO (Young) and NMSS Events Notification group via email.
Power Reactor
Event Number: 55529
Facility: Prairie Island
Region: 3 State: MN
Unit: [2] [] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: Tim Kohrs
HQ OPS Officer: Brian Lin
Region: 3 State: MN
Unit: [2] [] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: Tim Kohrs
HQ OPS Officer: Brian Lin
Notification Date: 10/18/2021
Notification Time: 04:05 [ET]
Event Date: 10/17/2021
Event Time: 19:30 [CDT]
Last Update Date: 12/13/2021
Notification Time: 04:05 [ET]
Event Date: 10/17/2021
Event Time: 19:30 [CDT]
Last Update Date: 12/13/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
PELKE, PATRICIA (R3)
PELKE, PATRICIA (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Refueling | 0 | Refueling |
EN Revision Imported Date: 12/14/2021
EN Revision Text: EMERGENCY DIESEL GENERATORS SIMULTANEOUSLY INOPERABLE
"At 1930 CDT on 10/17/2021, it was discovered both of the Unit 2 Emergency Diesel Generators were simultaneously INOPERABLE with a requirement to have one OPERABLE train; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10CFR 50.72(b)(3)(v). Offsite power was OPERABLE during this event.
"There was no impact on the health and safety of the public or plant personnel. The NRC Senior Resident Inspector has been notified."
The cause was corrected and both Emergency Diesel Generators are currently operable.
* * * RETRACTION ON 12/13/2021 AT 1607 EST FROM CARLOS PARADA TO LLOYD DESOTELL * * *
* The following information was provided by the licensee via email:
"This is a retraction of Event Notification EN55529 in accordance with 10 CFR 50.72(b)(3)(v)(D) made by the Prairie Island Nuclear Generating Plant on October 18, 2021. The original notification stemmed from a loss of power to the non-safety related Unit 2 Emergency Diesel Generator (EDG) starting air compressors. The resulting pressure decay in the EDG starting air receivers led to a decision to declare both EDGs inoperable. A subsequent engineering evaluation has provided reasonable assurance that the Unit 2 EDGs were operable and capable of performing their safety function during the time power was lost.
"The NRC Resident Inspector has been notified."
The HOO notified R3DO (Skokowski).
EN Revision Text: EMERGENCY DIESEL GENERATORS SIMULTANEOUSLY INOPERABLE
"At 1930 CDT on 10/17/2021, it was discovered both of the Unit 2 Emergency Diesel Generators were simultaneously INOPERABLE with a requirement to have one OPERABLE train; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10CFR 50.72(b)(3)(v). Offsite power was OPERABLE during this event.
"There was no impact on the health and safety of the public or plant personnel. The NRC Senior Resident Inspector has been notified."
The cause was corrected and both Emergency Diesel Generators are currently operable.
* * * RETRACTION ON 12/13/2021 AT 1607 EST FROM CARLOS PARADA TO LLOYD DESOTELL * * *
* The following information was provided by the licensee via email:
"This is a retraction of Event Notification EN55529 in accordance with 10 CFR 50.72(b)(3)(v)(D) made by the Prairie Island Nuclear Generating Plant on October 18, 2021. The original notification stemmed from a loss of power to the non-safety related Unit 2 Emergency Diesel Generator (EDG) starting air compressors. The resulting pressure decay in the EDG starting air receivers led to a decision to declare both EDGs inoperable. A subsequent engineering evaluation has provided reasonable assurance that the Unit 2 EDGs were operable and capable of performing their safety function during the time power was lost.
"The NRC Resident Inspector has been notified."
The HOO notified R3DO (Skokowski).