Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for November 12, 2021

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/11/2021 - 11/12/2021

Agreement State
Event Number: 55283
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: Raba-Kistner Consultants
Region: 4
City: San Antonio   State: TX
County:
License #: L-01571
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Kerby Scales
Notification Date: 05/30/2021
Notification Time: 14:39 [ET]
Event Date: 05/30/2021
Event Time: 00:00 [CDT]
Last Update Date: 11/10/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
GEPFORD, HEATHER (R4)
ILTAB, (EMAIL)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
CNSNS (MEXICO), - (EMAIL)
Event Text
EN Revision Imported Date: 11/12/2021

EN Revision Text: AGREEMENT STATE REPORT - STOLEN GUAGE

The following was received from the Texas Department of State Health Services (the Agency) via email:

"On May 30, 2021, the Agency was notified by the licensee's radiation safety officer (RSO) that a Humboldt model 5001 EZ was stolen from a truck parked overnight at a technician's home. The gauge contains a 40 millicurie americium - 241 source and an 10 millicurie cesium - 137 source. The technician had taken the gauge home on May 29, 2021. The gauge was locked in the truck with two independent chains and locks. The technician went to their truck at 0900 [CDT] on May 30, 2021 and found both were cut and the transport case and the gauge were stolen. The RSO stated the operating arm was locked in the shielded position. The RSO stated the technician drove around in the immediate area in an attempt to find the gauge. The RSO stated local law enforcement had been notified. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident Number: 9852

* * * UPDATE ON 11/10/21 AT 1727 EST FROM ART TUCKER (VIA EMAIL) TO HOWIE CROUCH * * *

"On November 10, 2021, the Agency was notified by the licensee that they had recovered the missing gauge on November 2, 2021. The licensee confirmed that the gauge cesium operating rod was locked in the shielded position. The licensee agreed to submit a written report to the Agency providing additional information."

Notified R4DO (Gaddy), Mexico CNSNS, ILTAB and NMSS Event Notifications via email.

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 55556
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Steris Applied Sterilization Technologies
Region: 3
City: Libertyville   State: IL
County: Lake
License #: IL-01123-02
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Dan Livermore
Notification Date: 11/03/2021
Notification Time: 10:46 [ET]
Event Date: 11/02/2021
Event Time: 05:00 [CDT]
Last Update Date: 11/03/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
McCraw, Aaron (R3)
NMSS_Events_Notification, (EMAIL)
Event Text
EN Revision Imported Date: 11/12/2021

EN Revision Text: AGREEMENT STATE REPORT - FIRE IN POOL IRRADIATOR FACILITY

The following information was received from Illinois Emergency Management Agency (Agency) via E-mail:

"The [Illinois Emergency Management] Agency was contacted at approximately 16:00 [CDT] on 11/2/21 by Isomedix Operations, Inc. (d/b/a Steris Applied Sterizliation Technologies, RML IL-01123-02) to advise of a fire in one of their irradiation cells that occurred at approximately 05:00 [CDT] this morning in Libertyville, IL. Sources, irradiator lift mechanisms, and associated safety/security systems were reportedly unaffected. Local fire personnel did respond, but maintenance crew were able to extinguish the fire prior to their arrival. This matter is reportable under 32 Ill. Adm. Code 346.830(a)(2).

"The radiation safety officer for Isomedix Operations, contacted the Agency at 16:00 [CDT] today and informed of a fire in a radiation room at their pool irradiator facility. Reportedly, maintenance crews were performing overhead welding in the source room when hot slag fell on a product tote. The tote was located near the portal entry of irradiator 192. The fire alarm was pulled and the maintenance crew was able to put out the fire using a handheld extinguisher. Local fire arrived, performed an investigation and departed without further concern. The irradiator was removed from service as Isomedix staff spent the duration of the day assessing safety systems. Water purity checks and exposure rates indicate no impacts to sources. Cables, cable shrouds and associated lifting mechanisms were assessed and were not impacted. Having found no additional radiological or safety mechanisms impacted, the facility returned to routine operations at 16:00 [CDT] today.

"IEMA staff are pursuing additional information from the licensee and performing a reactionary inspection on 11/3/21. Additional information will be communicated as it becomes available."

Illinois Report Number : IL210036


Agreement State
Event Number: 55557
Rep Org: MA Radiation Control Program
Licensee: Tufts Medical Center
Region: 1
City: Boston   State: MA
County:
License #: 60-0160
Agreement: Y
Docket:
NRC Notified By: Anthony Carpenito
HQ OPS Officer: Jim Drake
Notification Date: 11/03/2021
Notification Time: 12:08 [ET]
Event Date: 11/02/2021
Event Time: 13:25 [EDT]
Last Update Date: 11/03/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Matt (R1)
NMSS_Events_Notification, (EMAIL)
Event Text
EN Revision Imported Date: 11/12/2021

EN Revision Text: AGREEMENT STATE REPORT - Y-90 MICROSPHERE MEDICAL EVENT

The following information was received from the Commonwealth of Massachusetts via email:

"On November 2, 2021, 3:00 PM [EDT], licensee reported medical event under license 60-0160 for Sirtex Wilmington LLC SIR-Spheres Y-90 microspheres (SS&D MA-1229-D-101-S) emerging technology for total administered activity that differed from prescribed treatment activity as documented in the written directive by 20 percent or more. A portion of a Y-90 5 mCi microsphere therapy treatment delivered to patient liver on November 2, 2021 remained in the delivery system causing delivery of approximately 3.67 mCi Y-90 of the prescribed 5 mCi. The error was discovered immediately after treatment. Administered dose to treatment area differed from prescribed dose by approximately 27 percent. Licensee stated the cause, including possible equipment malfunction, has not yet been determined. Prescribing physician, referring physician and patient have been notified. Licensee stated no negative health effects to patient due to situation. No additional Y-90 therapy treatment would be required due to this situation. Licensee stated all Y-90 was accounted for. Licensee stated 5 mCi prescription was unusually small compared to previous procedures (range 9-to-39 mCi with 15 mCi being the most prescribed dose). Licensee to submit written report within 15 days of discovery date. This is a next day reportable medical event per regulation.

Investigation ongoing. Agency considers this event docket to still be OPEN.

Report by Anthony Carpenito, 11/3/2021.


Agreement State
Event Number: 55559
Rep Org: Texas Dept of State Health Services
Licensee: MAS-TEK Engineering and Associates Inc
Region: 4
City: Dallas   State: TX
County:
License #: L04864
Agreement: Y
Docket:
NRC Notified By: Matthew Kennington
HQ OPS Officer: Thomas Kendzia
Notification Date: 11/03/2021
Notification Time: 16:21 [ET]
Event Date: 08/30/2021
Event Time: 00:00 [CDT]
Last Update Date: 11/03/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Kozal, Jason (R4)
NMSS_Events_Notification, (EMAIL)
ILTAB, (EMAIL)
CNSNS (Mexico), - (EMAIL)
Event Text
EN Revision Imported Date: 11/12/2021

EN Revision Text: AGREEMENT STATE REPORT - MISSING MOISTURE DENSITY GAUGE

The following information was received from the State of Texas via email:

"On November 3, 2021, a licensee reported a moisture density gauge was discovered missing on August 30, 2021. The licensee's attempts to locate the gauge were unsuccessful. The licensee last had eyes on the gauge during the previous inventory in January of 2021. The gauge is a Humbolt model 5001 serial 7442 containing 10 mCi of Cs-137 with serial 2376CZ and 40 mCi of Am-241 with serial 404-09. The empty transport container with locks on the latches was present at the licensee's storage location. The gauge may not be inside a transport container. The licensee was unsure if a lock was present on the source rod. The incident was reported to the local police department. More information will be provided per SA 300 as it is obtained."

Texas incident no.: 9892

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 55562
Rep Org: Louisiana DEQ
Licensee: Source Production & Equipment Co.
Region: 4
City: St. Rose   State: LA
County:
License #: LA-2966-L01
Agreement: Y
Docket:
NRC Notified By: Richard S Blackwell
HQ OPS Officer: Mike Stafford
Notification Date: 11/05/2021
Notification Time: 12:24 [ET]
Event Date: 11/05/2021
Event Time: 10:45 [CDT]
Last Update Date: 11/05/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Kozal, Jason (R4)
NMSS_Events_Notification, (EMAIL)
Event Text
EN Revision Imported Date: 11/15/2021

EN Revision Text: AGREEMENT STATE REPORT - IMPROPER SOURCE SHIPMENT

The following was received from the Louisiana Department of Environmental Quality (DEQ) via email:

"Louisiana DEQ was notified by Source Production & Equipment (SPEC) Radiation Safety Officer, via the DEQ Radiation Hotline at approximately 1045 CDT on November 5, 2021, concerning an industrial radiography camera shipment from Nigeria. According to the RSO, Dynaquest Energy Limited in Nigeria wanted to exchange three Industrial Radiography Ir-192 sources. When the package was received, two of the drums had the Industrial Radiography cameras (SPEC 150) and the other drum did not have a camera just the unshielded source. The unshielded source was in the type B container without a camera. The source is an Ir-192 with 0.06987 Ci. The reading on the side of the drum was 300 mR/hr and the reading from the top of the drum with the lid off was 40 - 50 mR/hr. SPEC retrieved the source and put it in a shield. The individual that was handling the package and retrieval received 5 mR exposure. The two cameras were a SPEC 150 (s/n 2619) with Ir-192 source s/n AF2815 and SPEC 150 (s/n 2618) with Ir-192 source s/n AF2814 and were locked. SPEC 150 (s/n 2618) did not have a locking cap on it even though the camera was locked. SPEC stated that they will hold on to the devices and terminate their relationship with Dynaquest Energy Limited."

Louisiana Event Report ID Number: LA 202100010


Power Reactor
Event Number: 55567
Facility: Pilgrim
Region: 1     State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: Brendan Kane
HQ OPS Officer: Howie Crouch
Notification Date: 11/09/2021
Notification Time: 13:33 [ET]
Event Date: 11/09/2021
Event Time: 10:40 [EST]
Last Update Date: 11/09/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Henrion, Mark (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Defueled 0 Defueled
Event Text
EN Revision Imported Date: 11/12/2021

EN Revision Text: OFFSITE NOTIFICATION DUE TO VIOLATION OF DISCHARGE PERMIT

"At 1040 hours EST, November 9, 2021, the site reported a violation of the station National Pollutant Discharge Elimination System permit. The 24-hour environmental report addressed an unauthorized discharge of 7,245 gallons of non-radiological water that was pumped into a storm drain to de-water an on-site electrical vault located outside of the protected area. This discharge occurred from 0800 to 1230 hours on November 8, 2021. Sampling and analysis of the vault water is in progress to assess for the presence of pollutants.

"This notification is being made solely as a four-hour, non-emergency notification for a Notification of Other Government Agency. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."

The licensee notified the U.S. Environmental Protection Agency and the Commonwealth of Massachusetts Department of Environmental Protection.


Non-Power Reactor
Event Number: 55568
Rep Org: Univ Of Missouri-Columbia (MISC)
Licensee: University Of Missouri
Region: 0
City: Columbia   State: MO
County: Boone
License #: R-103
Agreement: N
Docket: 05000186
NRC Notified By: Bruce Meffert
HQ OPS Officer: Brian Lin
Notification Date: 11/09/2021
Notification Time: 23:50 [ET]
Event Date: 11/08/2021
Event Time: 00:00 [CST]
Last Update Date: 11/10/2021
Emergency Class: Non Emergency
10 CFR Section:
Person (Organization):
Wertz, Geoffrey (PM)
Takacs, Michael (NPR COOR)
Event Text
EN Revision Imported Date: 11/12/2021

EN Revision Text: TECHNICAL SPECIFICATION VIOLATION

"This is a required notification per University Of Missouri Research Reactor (MURR) Technical Specification (TS) 6.6.c(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, had occurred. MURR was not in compliance with one Limiting Conditions of Operations (LCO). TS 3.2.f states, 'The reactor shall not be operated unless the following rod run-in functions are operable.' Specifically, the rod run-in function that occurs when water level in the anti-siphon system is greater than or equal to 6 inches above the anti-siphon isolation valves was not operable as required by TS 3.2.f.6.

"On 11/8/21 while the reactor was shut down for maintenance and conducting surveillance testing on the anti-siphon system high level rod run-in instrument channel, the surveillance testing provided measurement that indicated the rod run-in actuation may not have occurred until water level was slightly greater than 6 inches above the anti-siphon isolation valves. Previously on 4/22/2021, the anti-siphon system high level rod run-in instrument channel activated the rod run-in well below the top of the anti-siphon isolation valves.

"Troubleshooting revealed the stainless-steel cable that connects the channel's level controller to its suspended displacer (float) had developed loops in it, effectively shortening the cable. The cable with loops made the rod run-in actuation occur at a higher water level than when the cable has no loops in it. The loops in the cable were removed. The instrument channel was retested and documented to be back in compliance with TS 3.2.f.6.

"On 11/9/21, MURR engineers analyzed the data collected from the 11/8/21 measurement and concluded that prior to removing the loops from the level controller cable, the rod run-in was actuating at a level of approximately 7.3 inches above the anti-siphon isolation valves, which is greater than the maximum of 6 inches above the valves required by TS 3.2.f.6.

"In accordance with TS 6.6.c(4) before it was known if MURR deviated from TS 3.2.f.6, the Acting Reactor Facility Director was briefed and gave permission to restart the reactor prior to the reactor returning to operation later on 11/8/21. Currently, MURR is operating at 10 MW. A detailed event report will follow within 14 days as required by MURR TS 6.6.c(3)."


Power Reactor
Event Number: 55570
Facility: North Anna
Region: 2     State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP,[3] M-4-LP
NRC Notified By: Marc Hofmann
HQ OPS Officer: Howie Crouch
Notification Date: 11/10/2021
Notification Time: 18:38 [ET]
Event Date: 11/10/2021
Event Time: 15:15 [EST]
Last Update Date: 11/12/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Miller, Mark (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
EN Revision Imported Date: 11/15/2021

EN Revision Text: OFFSITE NOTIFICATION DUE TO PCB OIL SPILL

"At 1515 EST on 11/10/21, approximately 89 gallons of PCB oil is unaccounted for from the Substation 'N' Transformer, located in the Owner Controlled Area. Transformer nameplate oil capacity is 569 gallons. Prior to removal of the original Substation 'N' Transformer, approximately 475 gallons of 10-CA-OIL (PCB Oil) was evacuated and stored by HEPACO (a licensee vendor). Approximately 5 gallons of oil is inaccessible to evacuate and remains in the original transformer. Below the transformer was evidence of oil leakage to the ground. The leakage appears to have been occurring over time, not as a result of a catastrophic failure. This condition is reportable to the Virginia Department of Environmental Quality (VA DEQ). The VA DEQ was notified of this condition at 1815 on 11/10/21. Cleanup activities are on-going.

"This event is reportable in accordance with 10CFR50.72(b)(2)(xi) for 'Any event or situation, related to the health and safety of the public or on-site personnel, or protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made. Such an event may include an on-site fatality or inadvertent release of radioactively contaminated materials.'"

The licensee will be notifying the Louisa County administrator and has notified the NRC Resident Inspector.

* * * UPDATE FROM MARC HOFMANN TO DONALD NORWOOD AT 1309 EST ON 11/12/2021 * * *

"Initial, unofficial, field testing performed by HEPACO indicated the oil released to the ground was PCB-Contaminated Oil. The official test results from the lab indicated that the oil is in fact not classified as PCB-Contaminated Oil. Therefore, this update is being made to EN55570 to clarify that the oil released to the environment was not PCB-Contaminated Oil."

The licensee notified the NRC Resident Inspector and the VA DEQ of this update.

Notified R2DO (Miller).


Power Reactor
Event Number: 55572
Facility: Beaver Valley
Region: 1     State: PA
Unit: [2] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Sean McGee
HQ OPS Officer: Donald Norwood
Notification Date: 11/12/2021
Notification Time: 13:52 [ET]
Event Date: 11/12/2021
Event Time: 10:07 [EST]
Last Update Date: 11/12/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Henrion, Mark (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 17 Power Operation 0 Power Operation
Event Text
MANUAL REACTOR TRIP DUE TO INCREASING STEAM GENERATOR WATER LEVELS

"At 1007 EST on November 12, 2021, with Unit 2 in Mode 1 at approximately 17 percent power following a refueling outage, the reactor was manually tripped due to increasing steam generator water levels due to an oscillating Main Feedwater Pump Recirculation Valve. Additionally, the Main Steam Isolation Valves were manually closed to prevent excessive reactor coolant system cooldown. Decay heat is being removed by discharging steam to the atmosphere using the Atmospheric Dump Valves.

"The trip was not complex, with all systems responding normally post-trip. There was no equipment inoperable prior to the event that contributed to the reactor trip or adversely impacted plant response. Operations responded and stabilized the plant.

"Beaver Valley Power Station Unit 1 is unaffected and remains at 100 percent power in Mode 1.

"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification, per 10 CFR 50.72(b)(2)(iv)(B).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 55574
Facility: Turkey Point
Region: 2     State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Humberto Benitez
HQ OPS Officer: Donald Norwood
Notification Date: 11/12/2021
Notification Time: 20:47 [ET]
Event Date: 11/12/2021
Event Time: 16:05 [EST]
Last Update Date: 11/12/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
Miller, Mark (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Hot Standby 0 Hot Standby
Event Text
REACTOR COOLANT SYSTEM PRESSURE BOUNDARY DEGRADED

"At 1605 EST on 11/12/21, it was determined that the RCS Pressure Boundary does not meet ASME Section XI, Table IWB-341 0-1, 'Acceptable Standards' due to a through wall leak of the Core Exit Thermocouple Nozzle Assembly.

"Measures have been taken to establish Mode 5 for corrective actions.

"This event is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(A).

"The NRC Resident Inspector has been notified.


Power Reactor
Event Number: 55575
Facility: Peach Bottom
Region: 1     State: PA
Unit: [2] [] []
RX Type: [2] GE-4,[3] GE-4
NRC Notified By: Chris Wainaina
HQ OPS Officer: Karen Cotton
Notification Date: 11/14/2021
Notification Time: 08:50 [ET]
Event Date: 11/14/2021
Event Time: 05:25 [EST]
Last Update Date: 11/14/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Henrion, Mark (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL TRIP DUE TO LOWERING MAIN CONDENSER VACUUM
At 0525 EST, November 14, 2021, "Unit 2 was manually scammed by operations due to lowering main condenser vacuum. This resulted in PCIS (process control and instrumentation system) Group II/III isolation signals. All control rods inserted, and all systems operated as designed."

Unit 3 is unaffected and remains at 100 percent power in Mode 1.

The Resident Inspector was notified.


Power Reactor
Event Number: 55576
Facility: Millstone
Region: 1     State: CT
Unit: [2] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Sunyoung Kwon
HQ OPS Officer: Donald Norwood
Notification Date: 11/14/2021
Notification Time: 17:06 [ET]
Event Date: 11/14/2021
Event Time: 11:50 [EST]
Last Update Date: 11/14/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(B) - Unanalyzed Condition
Person (Organization):
Henrion, Mark (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
NON-FUNCTIONAL STEAM SUPPLY CHECK VALVE TO TURBINE DRIVEN AUXILIARY FEEDWATER PUMP

"On November 14, 2021, at 1150 EST, while operating in Mode 1 at 100 percent power, the supply check valve from the Number 2 steam generator to the turbine driven auxiliary feedwater pump was determined during troubleshooting that it is not able to perform its isolation function. This failure would have resulted in the blowdown of both steam generators during a main steam line break in the Number 2 steam generator main steam line upstream of the main steam isolation valves until the operators could isolate the faulted steam generator. Previous evaluation has determined that this condition constituted an unanalyzed condition that could impact containment pressure.

"There has been no radioactive release to the environment. The steam lines from the steam generators to the turbine driven auxiliary feedwater pump have been isolated by use of a motor operated valve in the discharge line of the Number 2 steam generator. There has been no impact to Unit 3 which remains at 100 percent power.

"The NRC Senior Resident has been notified.

"This condition is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(B) as a condition that resulted in the nuclear power plant being in an unanalyzed condition that significantly degrades plant safety."