Event Notification Report for November 02, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
11/01/2021 - 11/02/2021
Agreement State
Event Number: 55542
Rep Org: Ohio Bureau of Radiation Protection
Licensee: University of Cincinnati Medical Center
Region: 3
City: Cincinnati State: OH
County:
License #: 02110310001
Agreement: Y
Docket:
NRC Notified By: Michael Rubadue
HQ OPS Officer: Brian P. Smith
Licensee: University of Cincinnati Medical Center
Region: 3
City: Cincinnati State: OH
County:
License #: 02110310001
Agreement: Y
Docket:
NRC Notified By: Michael Rubadue
HQ OPS Officer: Brian P. Smith
Notification Date: 10/25/2021
Notification Time: 15:40 [ET]
Event Date: 10/22/2021
Event Time: 12:00 [EDT]
Last Update Date: 10/25/2021
Notification Time: 15:40 [ET]
Event Date: 10/22/2021
Event Time: 12:00 [EDT]
Last Update Date: 10/25/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Orlikowski, Robert (R3)
NMSS_Events_Notification, (EMAIL)
Orlikowski, Robert (R3)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 11/2/2021
EN Revision Text: AGREEMENT STATE - EQUIPMENT FAILURE
The following report was received by the Ohio Bureau of Radiation Protection via email:
"The licensee reported a Varian Varisource 200 HDR unit failed to indicate the source was fully retracted at the conclusion of patient treatment. The licensee initiated emergency procedures and entered the room. Surveys confirmed the source had fully retracted into the unit and the patient did not receive any additional dose beyond what was prescribed. The unit console has been locked and placed out of service until the manufacturer can inspect and repair the device."
Ohio Report Number: OH210008
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE - EQUIPMENT FAILURE
The following report was received by the Ohio Bureau of Radiation Protection via email:
"The licensee reported a Varian Varisource 200 HDR unit failed to indicate the source was fully retracted at the conclusion of patient treatment. The licensee initiated emergency procedures and entered the room. Surveys confirmed the source had fully retracted into the unit and the patient did not receive any additional dose beyond what was prescribed. The unit console has been locked and placed out of service until the manufacturer can inspect and repair the device."
Ohio Report Number: OH210008
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 55543
Rep Org: NJ Dept of Environmental Protection
Licensee: SOFIE
Region: 1
City: Totowa State: NJ
County:
License #: 832599-RAD-210001
Agreement: Y
Docket:
NRC Notified By: Nancy Stanley
HQ OPS Officer: Brian P. Smith
Licensee: SOFIE
Region: 1
City: Totowa State: NJ
County:
License #: 832599-RAD-210001
Agreement: Y
Docket:
NRC Notified By: Nancy Stanley
HQ OPS Officer: Brian P. Smith
Notification Date: 10/25/2021
Notification Time: 16:36 [ET]
Event Date: 10/25/2021
Event Time: 10:45 [EDT]
Last Update Date: 10/25/2021
Notification Time: 16:36 [ET]
Event Date: 10/25/2021
Event Time: 10:45 [EDT]
Last Update Date: 10/25/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Ferdas, Marc (R1)
NMSS_Events_Notification, (EMAIL)
Ferdas, Marc (R1)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 11/2/2021
EN Revision Text: AGREEMENT STATE - CONTAMINATED PACKAGE
The following information was received from the New Jersey Department of Environmental Protection via email:
"At 1030 EDT on October 25, 2021, a package containing Zr-89 was received from the common carrier (airway bill number 770242368189) at the licensee's facility in New Jersey. At 1045 EDT, the package was wipe tested by a licensee employee and results indicated a high level of removable contamination. The bottom of the box read 217,410 counts per minute (cpm), while the background read 1,510 cpm. The box was opened and the top of the lead pig which holds the vial of liquid (approximately 200 microliters) radioactive Zr-89, which was 2,139 MBq at time of packaging on October 22, 2021, was found to be detached from the bottom of the lead pig. Pieces of the vial were observed to be outside of the lead pig which indicates the vial was indeed broken. The box was re-sealed and placed into the cyclotron vault at the licensee's facility for safety and containment purposes. At 1100 EDT, the Zr-89 manufacturer and shipper were notified of the situation. The box has been secured and contained within the cyclotron vault, 50 feet away from personnel at the facility."
EN Revision Text: AGREEMENT STATE - CONTAMINATED PACKAGE
The following information was received from the New Jersey Department of Environmental Protection via email:
"At 1030 EDT on October 25, 2021, a package containing Zr-89 was received from the common carrier (airway bill number 770242368189) at the licensee's facility in New Jersey. At 1045 EDT, the package was wipe tested by a licensee employee and results indicated a high level of removable contamination. The bottom of the box read 217,410 counts per minute (cpm), while the background read 1,510 cpm. The box was opened and the top of the lead pig which holds the vial of liquid (approximately 200 microliters) radioactive Zr-89, which was 2,139 MBq at time of packaging on October 22, 2021, was found to be detached from the bottom of the lead pig. Pieces of the vial were observed to be outside of the lead pig which indicates the vial was indeed broken. The box was re-sealed and placed into the cyclotron vault at the licensee's facility for safety and containment purposes. At 1100 EDT, the Zr-89 manufacturer and shipper were notified of the situation. The box has been secured and contained within the cyclotron vault, 50 feet away from personnel at the facility."
Agreement State
Event Number: 55544
Rep Org: Arizona Dept of Health Services
Licensee: Honorhealth dba Scottsdale Osborn Medical Center
Region: 4
City: Scottsdale State: AZ
County:
License #: 07-177
Agreement: Y
Docket:
NRC Notified By: Brian D. Goretzki
HQ OPS Officer: Lloyd Desotell
Licensee: Honorhealth dba Scottsdale Osborn Medical Center
Region: 4
City: Scottsdale State: AZ
County:
License #: 07-177
Agreement: Y
Docket:
NRC Notified By: Brian D. Goretzki
HQ OPS Officer: Lloyd Desotell
Notification Date: 10/26/2021
Notification Time: 11:03 [ET]
Event Date: 10/25/2021
Event Time: 00:00 [MST]
Last Update Date: 10/26/2021
Notification Time: 11:03 [ET]
Event Date: 10/25/2021
Event Time: 00:00 [MST]
Last Update Date: 10/26/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Pick, Greg (R4)
NMSS_Events_Notification, (EMAIL)
Pick, Greg (R4)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 11/3/2021
EN Revision Text: AGREEMENT STATE REPORT - DISLODGED I-125 EYE PLAQUE
The following information was received from the Arizona Department of Health Services (the Department) via email:
"On October 25, 2021, the Department received notification that an I-125 eye plaque became dislodged from a patient's eye and fell to the floor. The eye plaque contained 30 Iso-Aid High Activity Advantage seeds with an activity of 1.33 mCi per seed. The patient placed the eye plaque in a lead pouch and then contacted the Authorized User, who was able to take possession of the seeds. The Ophthalmologist that performed the surgery has been notified. The Department has requested additional information and continues to investigate the event.
"Additional information will be provided as it is received in accordance with SA-300."
Arizona Incident No: 21-007
EN Revision Text: AGREEMENT STATE REPORT - DISLODGED I-125 EYE PLAQUE
The following information was received from the Arizona Department of Health Services (the Department) via email:
"On October 25, 2021, the Department received notification that an I-125 eye plaque became dislodged from a patient's eye and fell to the floor. The eye plaque contained 30 Iso-Aid High Activity Advantage seeds with an activity of 1.33 mCi per seed. The patient placed the eye plaque in a lead pouch and then contacted the Authorized User, who was able to take possession of the seeds. The Ophthalmologist that performed the surgery has been notified. The Department has requested additional information and continues to investigate the event.
"Additional information will be provided as it is received in accordance with SA-300."
Arizona Incident No: 21-007
Agreement State
Event Number: 55545
Rep Org: California Radiation Control Prgm
Licensee: CTE CAL, Inc.
Region: 4
City: Fremont State: CA
County:
License #: 8327-01
Agreement: Y
Docket:
NRC Notified By: Arunika Hewadikaram
HQ OPS Officer: Donald Norwood
Licensee: CTE CAL, Inc.
Region: 4
City: Fremont State: CA
County:
License #: 8327-01
Agreement: Y
Docket:
NRC Notified By: Arunika Hewadikaram
HQ OPS Officer: Donald Norwood
Notification Date: 10/26/2021
Notification Time: 18:59 [ET]
Event Date: 10/26/2021
Event Time: 05:30 [PDT]
Last Update Date: 10/26/2021
Notification Time: 18:59 [ET]
Event Date: 10/26/2021
Event Time: 05:30 [PDT]
Last Update Date: 10/26/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Pick, Greg (R4)
ILTAB, (EMAIL)
NMSS_Events_Notification, (EMAIL)
CNSNS (Mexico), - (EMAIL)
Pick, Greg (R4)
ILTAB, (EMAIL)
NMSS_Events_Notification, (EMAIL)
CNSNS (Mexico), - (EMAIL)
EN Revision Imported Date: 11/3/2021
EN Revision Text: AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE
The following information was received via E-mail:
"On 10/26/21, California Office of Emergency Services (CALOES) contacted the Radiologic Health Branch (RHB) to report a stolen moisture density gauge. The gauge stolen is a Troxler Model 3430, S/N 23760, containing 9 mCi of Cs-137 and 44 mCi of Am-241. The report stated that the gauge was stolen out of user's truck parked at his residence located in San Leandro, CA, between 5:30-6:00 a.m. PDT on 10/26/2021. The licensee had notified San Leandro Police Department of the theft (report number unavailable).
"RHB will be following up on this investigation."
California 5010 Number: 102621
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE
The following information was received via E-mail:
"On 10/26/21, California Office of Emergency Services (CALOES) contacted the Radiologic Health Branch (RHB) to report a stolen moisture density gauge. The gauge stolen is a Troxler Model 3430, S/N 23760, containing 9 mCi of Cs-137 and 44 mCi of Am-241. The report stated that the gauge was stolen out of user's truck parked at his residence located in San Leandro, CA, between 5:30-6:00 a.m. PDT on 10/26/2021. The licensee had notified San Leandro Police Department of the theft (report number unavailable).
"RHB will be following up on this investigation."
California 5010 Number: 102621
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55547
Rep Org: Louisiana Deq
Licensee: QSA Global, Inc.
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-5934-L01
Agreement: Y
Docket:
NRC Notified By: Richard Blackwell
HQ OPS Officer: Donald Norwood
Licensee: QSA Global, Inc.
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-5934-L01
Agreement: Y
Docket:
NRC Notified By: Richard Blackwell
HQ OPS Officer: Donald Norwood
Notification Date: 10/27/2021
Notification Time: 14:32 [ET]
Event Date: 10/26/2021
Event Time: 15:50 [CDT]
Last Update Date: 10/27/2021
Notification Time: 14:32 [ET]
Event Date: 10/26/2021
Event Time: 15:50 [CDT]
Last Update Date: 10/27/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Pick, Greg (R4)
NMSS_Events_Notification, (EMAIL)
Gott, William (IR)
Pick, Greg (R4)
NMSS_Events_Notification, (EMAIL)
Gott, William (IR)
EN Revision Imported Date: 11/3/2021
EN Revision Text: AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA DELIVERED TO WRONG ADDRESS
The following is a synopsis of information received via E-mail:
The Louisiana Department of Environmental Quality (LDEQ) was notified by the QSA Global Radiation Safety Officer (RSO) concerning an industrial radiography camera that had been shipped, but did not reach its intended destination on October 26, 2021. This notification was made via the LDEQ Radiation Hotline at approximately 1215 CDT on October 27, 2021. According to the QSA Global RSO, the common carrier said the package had been delivered on October 26, 2021 at 1550 CDT and signed for by an individual. The RSO for Ohmstede, the intended recipient, said the package had not been delivered. The package with the industrial radiography camera, a QSA Global model 880 Delta (s/n D11151) with 105 Ci of Ir-192 (s/n 34970M), was mistakenly delivered to an address on Hwy 75 instead of the correct address on Highway 30, St. Gabriel, LA. On October 27, 2021, the common carrier driver picked up the package from the incorrect address and delivered it to the correct location around 1300 CDT on October 27, 2021. No further action required.
Louisiana Event Report ID No.: LA 20210009
THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA DELIVERED TO WRONG ADDRESS
The following is a synopsis of information received via E-mail:
The Louisiana Department of Environmental Quality (LDEQ) was notified by the QSA Global Radiation Safety Officer (RSO) concerning an industrial radiography camera that had been shipped, but did not reach its intended destination on October 26, 2021. This notification was made via the LDEQ Radiation Hotline at approximately 1215 CDT on October 27, 2021. According to the QSA Global RSO, the common carrier said the package had been delivered on October 26, 2021 at 1550 CDT and signed for by an individual. The RSO for Ohmstede, the intended recipient, said the package had not been delivered. The package with the industrial radiography camera, a QSA Global model 880 Delta (s/n D11151) with 105 Ci of Ir-192 (s/n 34970M), was mistakenly delivered to an address on Hwy 75 instead of the correct address on Highway 30, St. Gabriel, LA. On October 27, 2021, the common carrier driver picked up the package from the incorrect address and delivered it to the correct location around 1300 CDT on October 27, 2021. No further action required.
Louisiana Event Report ID No.: LA 20210009
THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55548
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Siemens Medical Solutions
Region: 3
City: Hoffman Estates State: IL
County:
License #: IL-01130-02
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Donald Norwood
Licensee: Siemens Medical Solutions
Region: 3
City: Hoffman Estates State: IL
County:
License #: IL-01130-02
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Donald Norwood
Notification Date: 10/27/2021
Notification Time: 16:11 [ET]
Event Date: 10/27/2021
Event Time: 00:00 [CDT]
Last Update Date: 10/27/2021
Notification Time: 16:11 [ET]
Event Date: 10/27/2021
Event Time: 00:00 [CDT]
Last Update Date: 10/27/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Orlikowski, Robert (R3)
NMSS_Events_Notification, (EMAIL)
Orlikowski, Robert (R3)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 11/3/2021
EN Revision Text: AGREEMENT STATE REPORT - FOUND Ge-68 SOURCE
The following information was received via E-mail:
"The Illinois Emergency Management Agency (the Agency / IEMA) was notified on 10/27/21 by Siemens Medical Solutions that a PET phantom source had been identified at a scrap recycling facility in Gilberts, Illinois. IEMA staff should be on site at approximately 1500 CDT today (10/27/21) to impound the source and assess for contamination. Updates will be provided as they become available.
"The radiation safety officer for Siemens Medical Solutions contacted the Agency to advise that a cylindrical PET phantom source (Ge-68, typically around 4 mCi) had been identified at Elgin Recycling. The Elgin Recycling facility is located in Gilberts, Illinois. Reportedly, the facility identified a shielded container (pig) and surveyed it prior to processing. Their handheld meter identified radioactivity and they contacted the manufacturer listed on the container (Siemens). Siemens advised the facility to secure the source away from the public and await pickup (likely late next week). Rather than have an unlicensed facility responsible for security, shielding and accountability of a licensed source; IEMA staff will facilitate pickup today and transfer the source over to Siemens staff when they are available next week.
"Preliminary information indicates the source was returned from India and sent to Hegele Logistics in Wood Dale, Illinois. Hegele Logistics failed to identify the source and sent the material for recycling. Agency staff have previously responded to Hegele Logistics in August of 2019. Siemens is researching the shipment to determine if additional sources could be present.
"Safety Assessment: Agency staff will retrieve information on the source and actions taken by Elgin Recycling staff which will facilitate a characterization of exposures, if any. Assuming the source has not decayed at all (271 day half-life), a 4 mCi Ge-68 source would have an exposure rate of approximately 2.3 mR/hour at one meter. The sources are typically a sealed, cylindrical epoxy not lending itself to removable contamination. Updates to this assessment will be provided."
Illinois Item Number: IL210034
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - FOUND Ge-68 SOURCE
The following information was received via E-mail:
"The Illinois Emergency Management Agency (the Agency / IEMA) was notified on 10/27/21 by Siemens Medical Solutions that a PET phantom source had been identified at a scrap recycling facility in Gilberts, Illinois. IEMA staff should be on site at approximately 1500 CDT today (10/27/21) to impound the source and assess for contamination. Updates will be provided as they become available.
"The radiation safety officer for Siemens Medical Solutions contacted the Agency to advise that a cylindrical PET phantom source (Ge-68, typically around 4 mCi) had been identified at Elgin Recycling. The Elgin Recycling facility is located in Gilberts, Illinois. Reportedly, the facility identified a shielded container (pig) and surveyed it prior to processing. Their handheld meter identified radioactivity and they contacted the manufacturer listed on the container (Siemens). Siemens advised the facility to secure the source away from the public and await pickup (likely late next week). Rather than have an unlicensed facility responsible for security, shielding and accountability of a licensed source; IEMA staff will facilitate pickup today and transfer the source over to Siemens staff when they are available next week.
"Preliminary information indicates the source was returned from India and sent to Hegele Logistics in Wood Dale, Illinois. Hegele Logistics failed to identify the source and sent the material for recycling. Agency staff have previously responded to Hegele Logistics in August of 2019. Siemens is researching the shipment to determine if additional sources could be present.
"Safety Assessment: Agency staff will retrieve information on the source and actions taken by Elgin Recycling staff which will facilitate a characterization of exposures, if any. Assuming the source has not decayed at all (271 day half-life), a 4 mCi Ge-68 source would have an exposure rate of approximately 2.3 mR/hour at one meter. The sources are typically a sealed, cylindrical epoxy not lending itself to removable contamination. Updates to this assessment will be provided."
Illinois Item Number: IL210034
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf