Event Notification Report for September 15, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/14/2021 - 09/15/2021
Agreement State
Event Number: 55446
Rep Org: NEW MEXICO RAD CONTROL PROGRAM
Licensee: CHRISTUS St. Vincent Regional Medical Center
Region: 4
City: Santa Fe State: NM
County:
License #: General License
Agreement: Y
Docket:
NRC Notified By: Carl Sullivan
HQ OPS Officer: Donald Norwood
Licensee: CHRISTUS St. Vincent Regional Medical Center
Region: 4
City: Santa Fe State: NM
County:
License #: General License
Agreement: Y
Docket:
NRC Notified By: Carl Sullivan
HQ OPS Officer: Donald Norwood
Notification Date: 09/07/2021
Notification Time: 12:30 [ET]
Event Date: 08/06/2021
Event Time: 00:00 [MDT]
Last Update Date: 09/07/2021
Notification Time: 12:30 [ET]
Event Date: 08/06/2021
Event Time: 00:00 [MDT]
Last Update Date: 09/07/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
TAYLOR, NICK (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
CNSNS (MEXICO) (EMAIL)
TAYLOR, NICK (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
CNSNS (MEXICO) (EMAIL)
EN Revision Imported Date: 9/15/2021
EN Revision Text: AGREEMENT STATE REPORT - LOST AMPULES FROM A TRITIUM EXIT SIGN
The following is a synopsis of information received via E-mail:
This event was originally reported via phone to the New Mexico Radiation Control Bureau on August 6, 2021.
This incident involved a double sided (2 sign faces) tritium exit sign. Specific details of the sign are: Radioactive Material: Tritium (H-3), Quantity: 7.5 Ci per sign face, Chemical and Physical form: Gas, Manufacturer: Sign Tex Inc.
This sign was located outside of the hospital building. The sign was damaged, and was then cleaned up by facilities and placed in a trash receptacle. The staff member who cleaned up the sign was confident that none of the glass ampules were broken and that all pieces were collected. The incident was then reported to the Safety Officer and the sign was removed from the waste bin. The Safety Officer then reported the sign to the RSO [Radiation Safety Officer] for guidance on how to properly dispose of the sign. Upon evaluation of the sign it was discovered that a part of one of the sign faces was missing. This piece includes the ampules which make up the letter "T" and an arrow (3 tubes total) of the sign. In addition, the sign casing was reported as missing. The activity information noted above was received from the sign manufacturer based off of the part number listed on the Order Acknowledgement document. The order date was reported as August 23, 2017. As there is no observable original date for the H-3, no decay correction was made in order to be conservative. It is currently assumed that the casing and the missing piece were disposed of, and due to the radiological properties, the piece was not detected by any waste radiation monitors. All remaining pieces of the sign are intact and were observed to glow, confirming that the ampules are not leaking.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST AMPULES FROM A TRITIUM EXIT SIGN
The following is a synopsis of information received via E-mail:
This event was originally reported via phone to the New Mexico Radiation Control Bureau on August 6, 2021.
This incident involved a double sided (2 sign faces) tritium exit sign. Specific details of the sign are: Radioactive Material: Tritium (H-3), Quantity: 7.5 Ci per sign face, Chemical and Physical form: Gas, Manufacturer: Sign Tex Inc.
This sign was located outside of the hospital building. The sign was damaged, and was then cleaned up by facilities and placed in a trash receptacle. The staff member who cleaned up the sign was confident that none of the glass ampules were broken and that all pieces were collected. The incident was then reported to the Safety Officer and the sign was removed from the waste bin. The Safety Officer then reported the sign to the RSO [Radiation Safety Officer] for guidance on how to properly dispose of the sign. Upon evaluation of the sign it was discovered that a part of one of the sign faces was missing. This piece includes the ampules which make up the letter "T" and an arrow (3 tubes total) of the sign. In addition, the sign casing was reported as missing. The activity information noted above was received from the sign manufacturer based off of the part number listed on the Order Acknowledgement document. The order date was reported as August 23, 2017. As there is no observable original date for the H-3, no decay correction was made in order to be conservative. It is currently assumed that the casing and the missing piece were disposed of, and due to the radiological properties, the piece was not detected by any waste radiation monitors. All remaining pieces of the sign are intact and were observed to glow, confirming that the ampules are not leaking.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55447
Rep Org: KENTUCKY DEPT OF RADIATION CONTROL
Licensee: St. Elizabeth Healthcare, Edgewood
Region: 1
City: Edgewood State: KY
County:
License #: 202-152-27
Agreement: Y
Docket:
NRC Notified By: Anjan Bhattacharyya
HQ OPS Officer: Donald Norwood
Licensee: St. Elizabeth Healthcare, Edgewood
Region: 1
City: Edgewood State: KY
County:
License #: 202-152-27
Agreement: Y
Docket:
NRC Notified By: Anjan Bhattacharyya
HQ OPS Officer: Donald Norwood
Notification Date: 09/07/2021
Notification Time: 15:09 [ET]
Event Date: 08/24/2021
Event Time: 11:00 [CDT]
Last Update Date: 09/07/2021
Notification Time: 15:09 [ET]
Event Date: 08/24/2021
Event Time: 11:00 [CDT]
Last Update Date: 09/07/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DENTEL, GLENN (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
DENTEL, GLENN (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 9/15/2021
EN Revision Text: AGREEMENT STATE REPORT - UNDER-DOSING EVENT WITH Y-90 THERASPHERES
The following information was received via E-mail:
"On 8/24/21, a Y-90 TheraSphere treatment was to deliver a planned 13.65 GBq to the patient's anterior right hepatic lobe. The written instructions were followed in the usual fashion and the dose was administered to the patient. The catheter and administration set tubing were placed into the waste container. The patient, personnel, and room were surveyed. No spill was detected. Upon post-calculation measurements, it was found that the patient only received approximately 77 percent of the expected dose of 200 Gray. While the received 154 Gray was medically appropriate given the patient's condition, tumor type and tumor location, this treatment still fell below that intended on the written directive. Further investigation found that this patient was rescheduled multiple times and the dose had decayed further than it was planned to, the patient really should have been treated the day before on a Monday instead of the Tuesday to get the full dose as planned or a new Treatment Window Illustrator to secure a more appropriate Y-90 dose should have been completed. Patient and referring provider were notified. There were no contaminations verified by survey meter measurements. The licensee is currently implementing an Excel spreadsheet program to review accuracy prior to patient scheduling and dose ordered. Reporting Criteria under 10 CFR 35.3045."
Kentucky Event Report ID No.: KY210002
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE REPORT - UNDER-DOSING EVENT WITH Y-90 THERASPHERES
The following information was received via E-mail:
"On 8/24/21, a Y-90 TheraSphere treatment was to deliver a planned 13.65 GBq to the patient's anterior right hepatic lobe. The written instructions were followed in the usual fashion and the dose was administered to the patient. The catheter and administration set tubing were placed into the waste container. The patient, personnel, and room were surveyed. No spill was detected. Upon post-calculation measurements, it was found that the patient only received approximately 77 percent of the expected dose of 200 Gray. While the received 154 Gray was medically appropriate given the patient's condition, tumor type and tumor location, this treatment still fell below that intended on the written directive. Further investigation found that this patient was rescheduled multiple times and the dose had decayed further than it was planned to, the patient really should have been treated the day before on a Monday instead of the Tuesday to get the full dose as planned or a new Treatment Window Illustrator to secure a more appropriate Y-90 dose should have been completed. Patient and referring provider were notified. There were no contaminations verified by survey meter measurements. The licensee is currently implementing an Excel spreadsheet program to review accuracy prior to patient scheduling and dose ordered. Reporting Criteria under 10 CFR 35.3045."
Kentucky Event Report ID No.: KY210002
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 55449
Rep Org: VIRGINIA RAD MATERIALS PROGRAM
Licensee: Inova Fairfax Medical Campus
Region: 1
City: Fairfax State: VA
County:
License #: 610-116-1
Agreement: Y
Docket:
NRC Notified By: Asfaw Fenta
HQ OPS Officer: Donald Norwood
Licensee: Inova Fairfax Medical Campus
Region: 1
City: Fairfax State: VA
County:
License #: 610-116-1
Agreement: Y
Docket:
NRC Notified By: Asfaw Fenta
HQ OPS Officer: Donald Norwood
Notification Date: 09/08/2021
Notification Time: 13:00 [ET]
Event Date: 09/02/2021
Event Time: 00:00 [EDT]
Last Update Date: 09/08/2021
Notification Time: 13:00 [ET]
Event Date: 09/02/2021
Event Time: 00:00 [EDT]
Last Update Date: 09/08/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DENTEL, GLENN (R1)
RIVERA-CAPELLA, GRETCHEN (NMSS DAY)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
DENTEL, GLENN (R1)
RIVERA-CAPELLA, GRETCHEN (NMSS DAY)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 9/16/2021
EN Revision Text: AGREEMENT STATE REPORT - MEDICAL EVENT INVOLVING Y-90 MICROSPHERES
The following information was received via E-mail:
"On September 7, 2021 at 1535 EDT, the Virginia Radioactive Materials Program (RMP) received a report from the licensee that a medical event involving Yttrium-90 microspheres occurred on September 2, 2021 (procedure date). The Authorized User (AU) discovered the event on September 3, 2021. According to the written directive, the prescribed dose to liver segments 2 and 3 was 130 Gy and to liver segments, 4 and 8 was also 130 Gy. After the procedure, the licensee discovered that the dose intended to liver segments 2 and 3 went to liver segment 4. As a result, liver segment 4 received the unintended dose of 54 Gy and the intended dose of 130 Gy for a sum of 184 Gy, which is a difference of 41.5 percent. The licensee reported that the cause of the event was a result of incorrect location of the delivery catheter and the patient was notified on September 3, 2021.
"The RMP will schedule to investigate the event and this report will be updated when the final investigation report is available."
Virginia Event Report ID No.: VA210005
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE REPORT - MEDICAL EVENT INVOLVING Y-90 MICROSPHERES
The following information was received via E-mail:
"On September 7, 2021 at 1535 EDT, the Virginia Radioactive Materials Program (RMP) received a report from the licensee that a medical event involving Yttrium-90 microspheres occurred on September 2, 2021 (procedure date). The Authorized User (AU) discovered the event on September 3, 2021. According to the written directive, the prescribed dose to liver segments 2 and 3 was 130 Gy and to liver segments, 4 and 8 was also 130 Gy. After the procedure, the licensee discovered that the dose intended to liver segments 2 and 3 went to liver segment 4. As a result, liver segment 4 received the unintended dose of 54 Gy and the intended dose of 130 Gy for a sum of 184 Gy, which is a difference of 41.5 percent. The licensee reported that the cause of the event was a result of incorrect location of the delivery catheter and the patient was notified on September 3, 2021.
"The RMP will schedule to investigate the event and this report will be updated when the final investigation report is available."
Virginia Event Report ID No.: VA210005
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Power Reactor
Event Number: 55458
Facility: McGuire
Region: 2 State: NC
Unit: [2] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Travis Rollins
HQ OPS Officer: Bethany Cecere
Region: 2 State: NC
Unit: [2] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Travis Rollins
HQ OPS Officer: Bethany Cecere
Notification Date: 09/13/2021
Notification Time: 05:53 [ET]
Event Date: 09/13/2021
Event Time: 00:11 [EDT]
Last Update Date: 09/13/2021
Notification Time: 05:53 [ET]
Event Date: 09/13/2021
Event Time: 00:11 [EDT]
Last Update Date: 09/13/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
MILLER, MARK (R2)
MILLER, MARK (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
EN Revision Imported Date: 9/15/2021
EN Revision Text: SPECIFIED SYSTEM ACTUATION
"At 0011 EDT, with Unit 2 in Mode 5 (Cold Shutdown), actuations of the 2B Diesel Generator (DG) and the 2B Motor Driven Auxiliary Feedwater (AFW) Pump occurred during Engineered Safety Features Actuation Periodic Testing while resetting the 2B DG Load Sequencer. The 2B DG was running unloaded following test actuation, and during realignment from the test, a blackout condition was experienced when the breaker opened supplying the 4160 Volt Essential Power System 2ETB from the Standby Auxiliary Power Transformer SATB. Sequencer actuation closed the emergency breaker to 2ETB and loaded the 2B Motor Driven AFW Pump onto the bus. Steam supply valves to the Turbine Driven AFW Pump were open from the previous test configuration.
"This event is being reported in accordance with 10CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the 2B DG and the 2B Motor Driven AFW Pump.
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
EN Revision Text: SPECIFIED SYSTEM ACTUATION
"At 0011 EDT, with Unit 2 in Mode 5 (Cold Shutdown), actuations of the 2B Diesel Generator (DG) and the 2B Motor Driven Auxiliary Feedwater (AFW) Pump occurred during Engineered Safety Features Actuation Periodic Testing while resetting the 2B DG Load Sequencer. The 2B DG was running unloaded following test actuation, and during realignment from the test, a blackout condition was experienced when the breaker opened supplying the 4160 Volt Essential Power System 2ETB from the Standby Auxiliary Power Transformer SATB. Sequencer actuation closed the emergency breaker to 2ETB and loaded the 2B Motor Driven AFW Pump onto the bus. Steam supply valves to the Turbine Driven AFW Pump were open from the previous test configuration.
"This event is being reported in accordance with 10CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the 2B DG and the 2B Motor Driven AFW Pump.
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
Power Reactor
Event Number: 55459
Facility: Surry
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Ken Wagar
HQ OPS Officer: Howie Crouch
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Ken Wagar
HQ OPS Officer: Howie Crouch
Notification Date: 09/13/2021
Notification Time: 23:47 [ET]
Event Date: 09/13/2021
Event Time: 18:22 [EDT]
Last Update Date: 09/14/2021
Notification Time: 23:47 [ET]
Event Date: 09/13/2021
Event Time: 18:22 [EDT]
Last Update Date: 09/14/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(B) - Unanalyzed Condition
10 CFR Section:
50.72(b)(3)(ii)(B) - Unanalyzed Condition
Person (Organization):
MILLER, MARK (R2)
MILLER, MARK (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
EN Revision Imported Date: 9/16/2021
EN Revision Text: UNANALYZED CONDITION OF FIRE SAFE SHUTDOWN EQUIPMENT
"On September 13, 2021, at 1822 EDT, an apparent non-compliance with 10 CFR 50, Appendix R, section III.G.2 (separation of redundant fire safe shutdown equipment) was identified. Specifically, it was determined that some Emergency Diesel Generator (EDG) cables may be susceptible to a hot short/spurious operation to the close circuit. A spurious closure of the emergency bus normal supply breakers after the EDG is powering the bus could result in non-synchronous paralleling, EDG overloading, or EDG output breaker tripping due to faulted power cable from normal supply breaker. The spurious closure of the normal supply breakers is not currently addressed in the Appendix R Report or previous Multiple Spurious Operations (MSO) analysis.
"This condition is associated with the Appendix R safe-shutdown function of the Emergency Power System. The Emergency Power System is considered operable but not fully qualified for its safety-related design function.
"The following fire areas are impacted:
1) Fire Area 13, Unit 1 Normal Switchgear Room
2) Fire Area 46, Unit 1 Cable Tray Room
3) Fire Area 3, Unit 1 Emergency Switchgear and Relay Room
4) Fire Area 2, Unit 2 Cable Vault and Tunnel
"Until this condition is analyzed, Surry has implemented mitigating actions in the above fire areas.
"This condition is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(B). This is also reportable as a 60-day written report pursuant to 10 CFR 50.73(a)(2)(ii)(B). This event was entered into the licensee's Corrective Action Program as CR [condition report] 1180502.
"The NRC Resident Inspector has been notified of this event."
Mitigating actions include posting fire watches in the affected areas.
EN Revision Text: UNANALYZED CONDITION OF FIRE SAFE SHUTDOWN EQUIPMENT
"On September 13, 2021, at 1822 EDT, an apparent non-compliance with 10 CFR 50, Appendix R, section III.G.2 (separation of redundant fire safe shutdown equipment) was identified. Specifically, it was determined that some Emergency Diesel Generator (EDG) cables may be susceptible to a hot short/spurious operation to the close circuit. A spurious closure of the emergency bus normal supply breakers after the EDG is powering the bus could result in non-synchronous paralleling, EDG overloading, or EDG output breaker tripping due to faulted power cable from normal supply breaker. The spurious closure of the normal supply breakers is not currently addressed in the Appendix R Report or previous Multiple Spurious Operations (MSO) analysis.
"This condition is associated with the Appendix R safe-shutdown function of the Emergency Power System. The Emergency Power System is considered operable but not fully qualified for its safety-related design function.
"The following fire areas are impacted:
1) Fire Area 13, Unit 1 Normal Switchgear Room
2) Fire Area 46, Unit 1 Cable Tray Room
3) Fire Area 3, Unit 1 Emergency Switchgear and Relay Room
4) Fire Area 2, Unit 2 Cable Vault and Tunnel
"Until this condition is analyzed, Surry has implemented mitigating actions in the above fire areas.
"This condition is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(B). This is also reportable as a 60-day written report pursuant to 10 CFR 50.73(a)(2)(ii)(B). This event was entered into the licensee's Corrective Action Program as CR [condition report] 1180502.
"The NRC Resident Inspector has been notified of this event."
Mitigating actions include posting fire watches in the affected areas.
Agreement State
Event Number: 55452
Rep Org: NJ DEPT OF ENVIRONMENTAL PROTECTION
Licensee: Atlantic Engineering Laboratory
Region: 1
City: Jersey City State: NJ
County:
License #: 506950
Agreement: Y
Docket:
NRC Notified By: Sarah Sanderlin
HQ OPS Officer: Donald Norwood
Licensee: Atlantic Engineering Laboratory
Region: 1
City: Jersey City State: NJ
County:
License #: 506950
Agreement: Y
Docket:
NRC Notified By: Sarah Sanderlin
HQ OPS Officer: Donald Norwood
Notification Date: 09/09/2021
Notification Time: 12:21 [ET]
Event Date: 09/06/2021
Event Time: 00:00 [EDT]
Last Update Date: 09/09/2021
Notification Time: 12:21 [ET]
Event Date: 09/06/2021
Event Time: 00:00 [EDT]
Last Update Date: 09/09/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DENTEL, GLENN (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
DENTEL, GLENN (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 9/16/2021
EN Revision Text: AGREEMENT STATE REPORT - STOLEN THEN RECOVERED PORTABLE GAUGE
The following information was received via E-mail:
"On 9/7/2021 the New Jersey Department of Environmental Protection was notified that a licensee Authorized User's (AU) car was stolen in Jersey City with a portable gauge inside. The gauge and vehicle were both recovered on 9/8/2021 and are currently in the licensee's possession. An update will be provided once additional information from the licensee is obtained."
* * * UPDATE FROM SARAH SANDERLIN TO DONALD NORWOOD AT 1621 EDT ON 9/9/2021 * * *
The following information was received via E-mail:
"On 9/7/2021 New Jersey Department of Environmental Protection (NJDEP) received notification from a licensee that an AU's car was stolen while containing radioactive material. NJDEP was informed by the licensee that the AU's personal vehicle was stolen from his residence in Jersey City on the night of 9/6/2021. The AU reported the missing vehicle to the police (report to be sent to NJDEP staff when received). By 1459 EDT on 9/8/2021 the AU found their vehicle on the street and notified the police who then released the vehicle back to them. The gauge was still secured in the vehicle with no signs of being tampered with."
Troxler portable gauge, Model 3430, S/N 20606 containing 9 mCi of Cs-137 and 44mCi of Am/Be-241.
Notified R1DO (Dentel) and NMSS Events Notification group.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - STOLEN THEN RECOVERED PORTABLE GAUGE
The following information was received via E-mail:
"On 9/7/2021 the New Jersey Department of Environmental Protection was notified that a licensee Authorized User's (AU) car was stolen in Jersey City with a portable gauge inside. The gauge and vehicle were both recovered on 9/8/2021 and are currently in the licensee's possession. An update will be provided once additional information from the licensee is obtained."
* * * UPDATE FROM SARAH SANDERLIN TO DONALD NORWOOD AT 1621 EDT ON 9/9/2021 * * *
The following information was received via E-mail:
"On 9/7/2021 New Jersey Department of Environmental Protection (NJDEP) received notification from a licensee that an AU's car was stolen while containing radioactive material. NJDEP was informed by the licensee that the AU's personal vehicle was stolen from his residence in Jersey City on the night of 9/6/2021. The AU reported the missing vehicle to the police (report to be sent to NJDEP staff when received). By 1459 EDT on 9/8/2021 the AU found their vehicle on the street and notified the police who then released the vehicle back to them. The gauge was still secured in the vehicle with no signs of being tampered with."
Troxler portable gauge, Model 3430, S/N 20606 containing 9 mCi of Cs-137 and 44mCi of Am/Be-241.
Notified R1DO (Dentel) and NMSS Events Notification group.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55454
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: Leesar, Incorporated
Region: 1
City: Fort Myers State: FL
County:
License #: 4311-1
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Donald Norwood
Licensee: Leesar, Incorporated
Region: 1
City: Fort Myers State: FL
County:
License #: 4311-1
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Donald Norwood
Notification Date: 09/09/2021
Notification Time: 16:57 [ET]
Event Date: 09/05/2021
Event Time: 17:00 [EDT]
Last Update Date: 09/09/2021
Notification Time: 16:57 [ET]
Event Date: 09/05/2021
Event Time: 17:00 [EDT]
Last Update Date: 09/09/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DENTEL, GLENN (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
DENTEL, GLENN (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 9/16/2021
EN Revision Text: AGREEMENT STATE REPORT - MINOR VEHICLE ACCIDENT WHILE TRANSPORTING A MEDICAL SOURCE
The following information was received via E-mail:
"The licensee Radiation Safety Officer (RSO) called the Florida Bureau of Radiation Control today, 9/9/21, to report a minor vehicle accident which occurred on Sunday afternoon, 9/5/21, around 1700 EDT, involving one of their Nuclear medicine drivers. The RSO indicated one of their pharmacists received a call on Sunday for a stat nuclear medicine delivery to Gulf Coast Hospital. The pharmacist's wife drove him in her personal vehicle to deliver the nuclear medicine but was involved in a minor vehicle accident on the way to deliver the meds. The RSO indicated the package was entirely intact with no breakage or leakage occurring. The pharmacy manager arrived on the scene to continue with the delivery while the pharmacist and his wife went to the hospital for evaluation. The Florida Bureau of Radiation Control is waiting for the police report and video surveillance from the pharmacy to complete the incident report."
Florida Incident Number: FL21-114
EN Revision Text: AGREEMENT STATE REPORT - MINOR VEHICLE ACCIDENT WHILE TRANSPORTING A MEDICAL SOURCE
The following information was received via E-mail:
"The licensee Radiation Safety Officer (RSO) called the Florida Bureau of Radiation Control today, 9/9/21, to report a minor vehicle accident which occurred on Sunday afternoon, 9/5/21, around 1700 EDT, involving one of their Nuclear medicine drivers. The RSO indicated one of their pharmacists received a call on Sunday for a stat nuclear medicine delivery to Gulf Coast Hospital. The pharmacist's wife drove him in her personal vehicle to deliver the nuclear medicine but was involved in a minor vehicle accident on the way to deliver the meds. The RSO indicated the package was entirely intact with no breakage or leakage occurring. The pharmacy manager arrived on the scene to continue with the delivery while the pharmacist and his wife went to the hospital for evaluation. The Florida Bureau of Radiation Control is waiting for the police report and video surveillance from the pharmacy to complete the incident report."
Florida Incident Number: FL21-114
Power Reactor
Event Number: 55462
Facility: Farley
Region: 2 State: AL
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Roosevelt Scott
HQ OPS Officer: Kerby Scales
Region: 2 State: AL
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Roosevelt Scott
HQ OPS Officer: Kerby Scales
Notification Date: 09/15/2021
Notification Time: 11:30 [ET]
Event Date: 09/15/2021
Event Time: 06:58 [CDT]
Last Update Date: 09/15/2021
Notification Time: 11:30 [ET]
Event Date: 09/15/2021
Event Time: 06:58 [CDT]
Last Update Date: 09/15/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
MILLER, MARK (R2)
BOWMAN, GREG (NRR EO)
GOTT, BILL (IRD MOC)
MILLER, MARK (R2)
BOWMAN, GREG (NRR EO)
GOTT, BILL (IRD MOC)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION DUE TO EMPLOYEE FATALITY
"At 0658 CDT on 09/15/2021 a non work-related death occurred of a site employee. The individual was outside of the Radiological Controlled Area. This is a four-hour notification, non-emergency for a notification of other government agency. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi). The NRC Resident Inspector has been notified."
"At 0658 CDT on 09/15/2021 a non work-related death occurred of a site employee. The individual was outside of the Radiological Controlled Area. This is a four-hour notification, non-emergency for a notification of other government agency. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi). The NRC Resident Inspector has been notified."
Part 21
Event Number: 55463
Rep Org: TE Connectivity
Licensee: TE Connectivity
Region: 1
City: Fairview State: NC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Lucinda Hodge
HQ OPS Officer: Brian Lin
Licensee: TE Connectivity
Region: 1
City: Fairview State: NC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Lucinda Hodge
HQ OPS Officer: Brian Lin
Notification Date: 09/15/2021
Notification Time: 12:14 [ET]
Event Date: 07/23/2021
Event Time: 00:00 [EDT]
Last Update Date: 09/15/2021
Notification Time: 12:14 [ET]
Event Date: 07/23/2021
Event Time: 00:00 [EDT]
Last Update Date: 09/15/2021
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
PART 21/50.55 REACTORS, - (EMAIL)
BOWER, FRED (R1DO)
MILLER, MARK (R2DO)
DICKSON, BILLY (R3DO)
AZUA, RAY (R4DO)
PART 21/50.55 REACTORS, - (EMAIL)
BOWER, FRED (R1DO)
MILLER, MARK (R2DO)
DICKSON, BILLY (R3DO)
AZUA, RAY (R4DO)
PART 21 - LOOSE CONNECTION ON EGP/ETR SERIES RELAYS
The following is a summary of information received from TE Connectivity via fax:
During Management of Change review on 7/23/21, TE Connectivity discovered test load was unconnected to HI-POT tester for EGP/ETR series relays. TE's investigation found a connection remained loose after scheduled calibration testing on 12/30/2020.
This report serves to document TE's evaluation and the corrective action taken on this issue:
1. A search of TE's database finds no occurrence of Dielectric Withstand Voltage (DWV) test failure at TE facility or similar failure with our customers in the field.
2. Many nuclear customers perform thorough inspections and testing prior to installing relays.
3. No customer history of EGP/ETR complaints of DWV failures found.
4. A series of corrective actions are now in place to guarantee full DWV testing to specification including: a mistake proof HI-POT test fixture developed and installed, and Hi-Pot test setup verification included as part of testing routine.
There have been no reported field failures for the identified impacted produce. However, out of an abundance of caution TE will notify customers of the issue and the option to return any relays potentially related to this issue for retesting and recertification.
Point of Contact:
Lucinda Hodge
Quality Manager
TE Connectivity, Aerospace Defense and Marine Division
1396 Charlotte Highway
Fairview, NC 28730
The following is a summary of information received from TE Connectivity via fax:
During Management of Change review on 7/23/21, TE Connectivity discovered test load was unconnected to HI-POT tester for EGP/ETR series relays. TE's investigation found a connection remained loose after scheduled calibration testing on 12/30/2020.
This report serves to document TE's evaluation and the corrective action taken on this issue:
1. A search of TE's database finds no occurrence of Dielectric Withstand Voltage (DWV) test failure at TE facility or similar failure with our customers in the field.
2. Many nuclear customers perform thorough inspections and testing prior to installing relays.
3. No customer history of EGP/ETR complaints of DWV failures found.
4. A series of corrective actions are now in place to guarantee full DWV testing to specification including: a mistake proof HI-POT test fixture developed and installed, and Hi-Pot test setup verification included as part of testing routine.
There have been no reported field failures for the identified impacted produce. However, out of an abundance of caution TE will notify customers of the issue and the option to return any relays potentially related to this issue for retesting and recertification.
Point of Contact:
Lucinda Hodge
Quality Manager
TE Connectivity, Aerospace Defense and Marine Division
1396 Charlotte Highway
Fairview, NC 28730