Skip to main content

Event Notification Report for July 30, 2021

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/29/2021 - 07/30/2021

EVENT NUMBERS
55388
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Non-Agreement State
Event Number: 55388
Rep Org: Rodriguez Sun Group
Licensee: Rodriguez Sun Group
Region: 1
City: Hormigueros   State: PR
County:
License #: 52-35550-01
Agreement: N
Docket:
NRC Notified By: Alfonso Hernandez Bosquel
HQ OPS Officer: Howie Crouch
Notification Date: 07/30/2021
Notification Time: 15:43 [ET]
Event Date: 07/30/2021
Event Time: 13:05 [EDT]
Last Update Date: 08/03/2021
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
CAHILL, CHRISTOPHER (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
Event Text
EN Revision Imported Date: 9/3/2021

EN Revision Text: DAMAGED INSTROTEK MOISTURE DENSITY GAUGE

The following is a summary of a phone call with the licensee:

On 7/30/2021 while at the jobsite in Moca, Puerto Rico, the licensee's InstroTek MC-3 Elite gauge was run over by a paving roller while in the safety drum. The gauge plastic casing was damaged and the source rod was broken. The sources were in the shielded position at the time of the incident. The InstroTek gauge serial number is 31331 and contains nominally 10 mCi of Cs-137 and 50 mCi of AmBe.

The damaged gauge was placed in its storage container and returned to the licensee's Cabo Rojo facility for a swipe test. After the incident, the gauge read 0.2 to 0.3 mR/hr at 1 meter with a survey meter.

No overexposures were reported.


* * * RETRACTION ON 8/3/21 AT 1320 EDT FROM ALFONSO BOSQUE TO KERBY SCALES * * *

The following retraction is a summary of a phone call with the licensee:

The Radiation Safety Officer inspected the gauge and verified that the gauge maintained its safety function. The source was secured and a leak test verified no leakage.

Notified R1DO (Eve) and NMSS Event Notification via email.