Event Notification Report for June 29, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/28/2021 - 06/29/2021
Part 21
Event Number: 55300
Rep Org: Paragon Energy Solutions
Licensee: Paragon Energy Solutions
Region: 4
City: Ft. Worth State: TX
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Tracy Bolt
HQ OPS Officer: Donald Norwood
Licensee: Paragon Energy Solutions
Region: 4
City: Ft. Worth State: TX
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Tracy Bolt
HQ OPS Officer: Donald Norwood
Notification Date: 06/10/2021
Notification Time: 15:56 [ET]
Event Date: 06/08/2021
Event Time: 00:00 [CDT]
Last Update Date: 06/28/2021
Notification Time: 15:56 [ET]
Event Date: 06/08/2021
Event Time: 00:00 [CDT]
Last Update Date: 06/28/2021
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
DRAKE, JAMES (R4)
MILLER, MARK (R2DO)
PART 21/50.55 REACTORS, - (EMAIL)
DRAKE, JAMES (R4)
MILLER, MARK (R2DO)
PART 21/50.55 REACTORS, - (EMAIL)
EN Revision Imported Date: 6/29/2021
EN Revision Text: PART 21 INITIAL REPORT - DEVIATION IDENTIFIED IN BOLTING UTILIZED TO MAINTAIN SEISMIC QUALIFICATION:
"Pursuant to 10 CFR 21.21 (d)(3)(i), Paragon Energy Solutions is providing initial notification of the identification of a deviation.
"Condition that requires evaluation:
"NLI 280-ton Custom Chillers, Serial Numbers XHX-0001A / XHX-0001B / XHX-0001C. The Chillers were originally supplied by Nuclear Logistics under PO: NU-02SR726683 in 2010.
"The original seismic qualification was questioned by plant personnel related to the size of the bolting utilized for the diagonal cross braces on the two lower chiller frames. Paragon performed a review and additional analysis of the original qualification report. It was confirmed that the bolting which was utilized to install the pinned diagonal braces on the condenser and compressor frame sections does not have a sufficient load bearing capacity to support the application loading during a seismic event.
"The upset and emergency loading for the diagonal brace is 5.59 kip and 8.59 kip, respectively. Compared to the load capacity of 2.32 kip and 3.09 kip for upset and emergency, respectively, for the 3/8" bolt in single-shear configuration with threads included in the shear plane.
"This condition does not affect normal operation of the chiller. However, this deviation has the potential to impact the ability to maintain structural integrity during a seismic event.
"Date of Discovery: 6/8/2021
"Formal notification will be submitted on or before 7/8/2021.
"Paragon contact: Tracy Bolt, Chief Nuclear Officer, Paragon Energy Solutions, 817-284-0077, tbolt@paragones.com."
This equipment was supplied to V.C. Summer Nuclear Station.
* * * UPDATE FROM TRACY BOLT TO DONALD NORWOOD ON 6/28/2021 AT 1459 EDT * * *
The following information was recevied via E-mail:
"Pursuant to 10 CFR 21.21(b), Paragon Energy Solutions, LLC is providing written notification of the identification of a deviation. On 6/24/2021, Paragon has determined that we do not have the capability to perform the evaluation to determine if the deviation, if left uncorrected, could create a substantial safety hazard. VC Summer has been notified within five working days of this determination so that they can evaluate the deviation or failure to comply, pursuant to 10 CFR 21.21(a).
"Condition that requires evaluation: NLI 280-ton Custom Chillers, Serial Numbers XHX-0001A / XHX-0001B / XHX-0001C. The Chillers were originally supplied by NLI to VC Summer station under PO: NU-02SR726683 in 2010. Ref. P21-06102021-IN, Rev. 0 (ML21174A009)
"Name and address of the individual or individuals informing the Commission: Tracy Bolt, Chief Nuclear Officer. Paragon Energy Solutions, LLC, 7410 Pebble Drive, Ft. Worth, TX 76118."
Notified R2DO (Miller), R4DO (Werner), and the Part 21/50.55 Reactors E-mail group.
EN Revision Text: PART 21 INITIAL REPORT - DEVIATION IDENTIFIED IN BOLTING UTILIZED TO MAINTAIN SEISMIC QUALIFICATION:
"Pursuant to 10 CFR 21.21 (d)(3)(i), Paragon Energy Solutions is providing initial notification of the identification of a deviation.
"Condition that requires evaluation:
"NLI 280-ton Custom Chillers, Serial Numbers XHX-0001A / XHX-0001B / XHX-0001C. The Chillers were originally supplied by Nuclear Logistics under PO: NU-02SR726683 in 2010.
"The original seismic qualification was questioned by plant personnel related to the size of the bolting utilized for the diagonal cross braces on the two lower chiller frames. Paragon performed a review and additional analysis of the original qualification report. It was confirmed that the bolting which was utilized to install the pinned diagonal braces on the condenser and compressor frame sections does not have a sufficient load bearing capacity to support the application loading during a seismic event.
"The upset and emergency loading for the diagonal brace is 5.59 kip and 8.59 kip, respectively. Compared to the load capacity of 2.32 kip and 3.09 kip for upset and emergency, respectively, for the 3/8" bolt in single-shear configuration with threads included in the shear plane.
"This condition does not affect normal operation of the chiller. However, this deviation has the potential to impact the ability to maintain structural integrity during a seismic event.
"Date of Discovery: 6/8/2021
"Formal notification will be submitted on or before 7/8/2021.
"Paragon contact: Tracy Bolt, Chief Nuclear Officer, Paragon Energy Solutions, 817-284-0077, tbolt@paragones.com."
This equipment was supplied to V.C. Summer Nuclear Station.
* * * UPDATE FROM TRACY BOLT TO DONALD NORWOOD ON 6/28/2021 AT 1459 EDT * * *
The following information was recevied via E-mail:
"Pursuant to 10 CFR 21.21(b), Paragon Energy Solutions, LLC is providing written notification of the identification of a deviation. On 6/24/2021, Paragon has determined that we do not have the capability to perform the evaluation to determine if the deviation, if left uncorrected, could create a substantial safety hazard. VC Summer has been notified within five working days of this determination so that they can evaluate the deviation or failure to comply, pursuant to 10 CFR 21.21(a).
"Condition that requires evaluation: NLI 280-ton Custom Chillers, Serial Numbers XHX-0001A / XHX-0001B / XHX-0001C. The Chillers were originally supplied by NLI to VC Summer station under PO: NU-02SR726683 in 2010. Ref. P21-06102021-IN, Rev. 0 (ML21174A009)
"Name and address of the individual or individuals informing the Commission: Tracy Bolt, Chief Nuclear Officer. Paragon Energy Solutions, LLC, 7410 Pebble Drive, Ft. Worth, TX 76118."
Notified R2DO (Miller), R4DO (Werner), and the Part 21/50.55 Reactors E-mail group.
Agreement State
Event Number: 55221
Rep Org: RI DEPT OF RADIOLOGICAL HEALTH
Licensee: Electric Boat Corporation
Region: 1
City: North Kingstown State: RI
County:
License #: 3D-005-01
Agreement: Y
Docket:
NRC Notified By: Alexander Hamm
HQ OPS Officer: Joanna Bridge
Licensee: Electric Boat Corporation
Region: 1
City: North Kingstown State: RI
County:
License #: 3D-005-01
Agreement: Y
Docket:
NRC Notified By: Alexander Hamm
HQ OPS Officer: Joanna Bridge
Notification Date: 04/29/2021
Notification Time: 13:59 [ET]
Event Date: 03/07/2021
Event Time: 01:20 [EDT]
Last Update Date: 06/29/2021
Notification Time: 13:59 [ET]
Event Date: 03/07/2021
Event Time: 01:20 [EDT]
Last Update Date: 06/29/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
SCHROEDER, DAN (R1DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
SCHROEDER, DAN (R1DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 6/30/2021
EN Revision Text: AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA SOURCE UNABLE TO RETRACT
The following was received via e-mail from the Rhode Island Dept. of Health, Radiation Control Agency:
"A licensee, Electric Boat Corporation, reported the inability to retract a 1.62 TBq (43.8 Ci) Co-60 source (QSA Global, Inc. Model A424-14, S/N 81346G) into the radiography exposure device (QSA Global, Inc. Model Sentry 330, S/N P30106) on March 7, 2021, at Electric Boat's Quonset Point Facility. At approximately 0120 [EDT], the [source] was [extended] without any issue.
"At the completion of the exposure, the radiographer attempted to retract the source into the exposure device, and attempted to re-expose the source to verify that the auto-locking mechanism on the Sentry 330 exposure device had engaged. At this time, the radiographer noted that the auto-lock did not engage and that dose rates indicated by his ND-2000A survey instrument at the reel (remote control) remained at approximately 10 mrem/hr. The radiographer then attempted to expose and retract the source to engage the locking mechanism 2 additional times without success.
"At approximately 0156 [EDT], the RSO [(Radiation Safety Officer)] was notified of the inability to retract a Cobalt-60 source into its exposure device. The RSO was able to observe the set up with an inspection mirror from the opposite side of the large part being inspected and determined that the guide tube had become disconnected from the collimator, exposing 10-12 feet of drive cable on the deck, and the source pigtail had become stuck in the collimator.
"After creating and briefing retrieval and contingency plans, source retrieval evolution began at 0640 [EDT]. The RSO Delegate secured the source pigtail in the collimator with a 6 ft long remote handling tool to prevent the source from leaving the collimator prematurely while the RSO stepped out from behind the lead shield with another 6 ft long remote handling tool to move the guide tube from the deck back up to the collimator. While the RSO was straightening out the guide tube and drive cable, a radiography supervisor was slowly retracting the drive cable at the reel to remove the 10-12 ft of drive cable slack on the deck while the RSO communicated via radio. Once the drive cable slack was removed and the RSO guided the guide tube back up to the collimator and tension on the source pigtail was released, the RSO Delegate released control of the source and it was immediately retracted by the radiography supervisor into the exposure device. The source was confirmed to be secured in its device by survey, and the evolution was declared secure at 0649 [EDT].
"RI Radiation Control Agency has investigated the report by Electric Boat Corporation and has determined that this does not have generic implications for the security of sources in radiography equipment at Electric Boat Corporation. The incident is considered closed by RI Radiation Control Agency."
* * * UPDATE ON 6/29/21 AT 1617 EDT FROM ALEXANDER HAMM TO BETHANY CECERE * * *
The following update was received via email from the Rhode Island Dept. of Health, Radiation Control Agency:
"Event Causes: 1) The first 1-3 male threads were rough, which lead to the female connection binding up prematurely. 2) The collimator connection was at or above the eye level of the radiographers, and obstructed from being able to perform a visual inspection of the connection. 3) Neither radiographer re-inspected nor verified the connection in the middle of the shift.
"Corrective Actions: By the licensee: 1) 2 collimators with male threads were identified as unsat and will be repaired or dispositioned for disposal by the RSO. 2) Thread protectors were procured and installed on equipment with exposed, male-threaded connections. 3) A Job Instruction Breakdown describing the connection and verification processes was developed."
Notified R1DO (Lilliendahl) and NMSS Events Notification (by email).
EN Revision Text: AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA SOURCE UNABLE TO RETRACT
The following was received via e-mail from the Rhode Island Dept. of Health, Radiation Control Agency:
"A licensee, Electric Boat Corporation, reported the inability to retract a 1.62 TBq (43.8 Ci) Co-60 source (QSA Global, Inc. Model A424-14, S/N 81346G) into the radiography exposure device (QSA Global, Inc. Model Sentry 330, S/N P30106) on March 7, 2021, at Electric Boat's Quonset Point Facility. At approximately 0120 [EDT], the [source] was [extended] without any issue.
"At the completion of the exposure, the radiographer attempted to retract the source into the exposure device, and attempted to re-expose the source to verify that the auto-locking mechanism on the Sentry 330 exposure device had engaged. At this time, the radiographer noted that the auto-lock did not engage and that dose rates indicated by his ND-2000A survey instrument at the reel (remote control) remained at approximately 10 mrem/hr. The radiographer then attempted to expose and retract the source to engage the locking mechanism 2 additional times without success.
"At approximately 0156 [EDT], the RSO [(Radiation Safety Officer)] was notified of the inability to retract a Cobalt-60 source into its exposure device. The RSO was able to observe the set up with an inspection mirror from the opposite side of the large part being inspected and determined that the guide tube had become disconnected from the collimator, exposing 10-12 feet of drive cable on the deck, and the source pigtail had become stuck in the collimator.
"After creating and briefing retrieval and contingency plans, source retrieval evolution began at 0640 [EDT]. The RSO Delegate secured the source pigtail in the collimator with a 6 ft long remote handling tool to prevent the source from leaving the collimator prematurely while the RSO stepped out from behind the lead shield with another 6 ft long remote handling tool to move the guide tube from the deck back up to the collimator. While the RSO was straightening out the guide tube and drive cable, a radiography supervisor was slowly retracting the drive cable at the reel to remove the 10-12 ft of drive cable slack on the deck while the RSO communicated via radio. Once the drive cable slack was removed and the RSO guided the guide tube back up to the collimator and tension on the source pigtail was released, the RSO Delegate released control of the source and it was immediately retracted by the radiography supervisor into the exposure device. The source was confirmed to be secured in its device by survey, and the evolution was declared secure at 0649 [EDT].
"RI Radiation Control Agency has investigated the report by Electric Boat Corporation and has determined that this does not have generic implications for the security of sources in radiography equipment at Electric Boat Corporation. The incident is considered closed by RI Radiation Control Agency."
* * * UPDATE ON 6/29/21 AT 1617 EDT FROM ALEXANDER HAMM TO BETHANY CECERE * * *
The following update was received via email from the Rhode Island Dept. of Health, Radiation Control Agency:
"Event Causes: 1) The first 1-3 male threads were rough, which lead to the female connection binding up prematurely. 2) The collimator connection was at or above the eye level of the radiographers, and obstructed from being able to perform a visual inspection of the connection. 3) Neither radiographer re-inspected nor verified the connection in the middle of the shift.
"Corrective Actions: By the licensee: 1) 2 collimators with male threads were identified as unsat and will be repaired or dispositioned for disposal by the RSO. 2) Thread protectors were procured and installed on equipment with exposed, male-threaded connections. 3) A Job Instruction Breakdown describing the connection and verification processes was developed."
Notified R1DO (Lilliendahl) and NMSS Events Notification (by email).
Part 21
Event Number: 55223
Rep Org: Paragon Energy Solutions
Licensee: Paragon Energy Solutions
Region: 4
City: Fort Worth State: TX
County:
License #:
Agreement: N
Docket:
NRC Notified By: Tracy Bolt
HQ OPS Officer: Joanna Bridge
Licensee: Paragon Energy Solutions
Region: 4
City: Fort Worth State: TX
County:
License #:
Agreement: N
Docket:
NRC Notified By: Tracy Bolt
HQ OPS Officer: Joanna Bridge
Notification Date: 04/29/2021
Notification Time: 19:52 [ET]
Event Date: 03/29/2021
Event Time: 00:00 [CDT]
Last Update Date: 06/29/2021
Notification Time: 19:52 [ET]
Event Date: 03/29/2021
Event Time: 00:00 [CDT]
Last Update Date: 06/29/2021
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
SCHROEDER, DAN (R1DO)
MILLER, MARK (R2DO)
RIEMER, KENNETH (R3DO)
PROULX, DAVID (R4DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
SCHROEDER, DAN (R1DO)
MILLER, MARK (R2DO)
RIEMER, KENNETH (R3DO)
PROULX, DAVID (R4DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 6/30/2021
EN Revision Text: PART 21 - FAILURE OF SIZE 1 AND 2 FREEDOM SERIES FULL VOLTAGE REVERSING STARTERS
The following is a summary of information received from Paragon Energy Solutions:
On 3/29/2021, Dominion - North Anna Station has identified instances where size 1 and 2 starters have failed to function as expected in assemblies that were originally supplied by Nuclear Logistics LLC (NLI). The mechanical interlock exhibited binding that prevented the contactor from closing when energized. The identified failed starters are utilized in an application of operating Motor Operated Valves (MOV). This is an intermittent duty application.
The issue was identified on Eaton Starter Model AN56DN*, AN56GN*, CN55DN*, CN55GN* style starters and contactors with supplied date codes T4514 (week 45 of year 2014) and T4215 (week 42 of year 2015). Paragon is in the process of identifying the date codes to provide the specific information to the identified plants.
The following plants were supplied starters from September 2014 through October 2018: Beaver Valley, Columbia, Ergytech, Harris, Millstone, NEK KRSKO, North Anna, Prairie Island.
The component design that exhibited the failure was revised by the original equipment manufacturer (Eaton) in October 2018. There have been no reported failures of the interlock mechanism in vintages manufactured before September 2014 or after October 2018.
These recommendations are based on the specific application: The reversing starters and reversing contactors are typically wired in a configuration that will electrically lock out one of the contactors when the other one is being energized to prevent both contactors from being energized at the same time. Therefore, the mechanical interlock is not required to prevent both contactors from being closed at the same time when the electrical interlock configuration is being implemented. In this scenario, the mechanical interlocks are not required and can be removed.
The motor control centers that contain the mechanical interlock should be monitored to ensure that there is no binding during operation.
The evaluation being performed by Paragon is expected to be completed by May 29, 2021.
Tracy Bolt
Chief Nuclear Officer, CNO
817-284-0077
Paragon Energy Solutions, LLC
7410 Pebble Drive
Ft. Worth, TX 76118
* * * UPDATE ON 5/3/2021 AT 1559 FROM TRACY BOLT TO BRIAN LIN * * *
The following revision was received from Paragon Energy Solutions via email and corrects the identified date code and includes the size and serial number of the starter that failed:
The issue was identified on supplied Size 1, 73262-025-00028 (Date Code: T4515 - 45th week of 2015) and Size 2, 73262-028-00001 (Date Code: T4215 - 42nd week of 2015).
Notified R1DO (Young), R2DO (Miller), R3DO (Orlikowski), R4DO (Deese), NMSS Events Notification, and Part 21 Group via email.
* * * UPDATE ON 5/28/2021 AT 1558 FROM TRACY BOLT TO KERBY SCALES * * *
The following update (Interim Report) was received from Paragon Energy Solutions via email:
"Paragon is submitting this Interim Report since this condition is currently under evaluation but will not be completed within 60 days.
"Paragon is in communication with EATON, the OEM for the starters/contactors to determine the extent of condition. The evaluation is expected to be completed by June 30, 2021.
"It was determined that Dominion - Millstone should not be included in the list of affected plants. Millstone will be removed from the list in the final revision of P21-03302021."
Notified R1DO (Bower), R2DO (Miller), R3DO (Feliz-Adorno), R4DO (Gepford), NMSS Events Notification, and Part 21 Group via email.
* * * UPDATE ON 6/29/2021 AT 1658 EDT FROM TRACY BOLT TO BETHANY CECERE * * *
The following is a synopsis of an update (completion of the evaluation) received from Paragon Energy Solutions via email:
"Paragon has identified the date codes of the supplied starters and contactors to provide the specific information to the identified plants. This information has been provided directly to the specific plant." [Millstone was removed from the list of plants.]
"The component design that exhibited the failure was revised by the original equipment manufacturer (EATON) in September of 2014. The failed units were from Date Codes T4215 and T4515 which are in the 42nd and 45th weeks of 2015. In September 2018 the drawing was revised again. In discussions with the OEM the revision of the drawing was due to a change in material type and was not a result of binding issues.
"This condition has not been identified on assemblies manufactured after September 2018.
"Due to the number of starters that have been installed and in service without issue, it is highly unlikely that there is a defect within all the supplied starters in the date range of September 2014 through September 2018. To date, Paragon has been unable to obtain any conclusive information from EATON regarding the potential cause of the binding issue. One of the failed starters along with samples of binding and non-binding interlocks have been provided to EATON for them to perform their own analysis on the potential causes of the binding issue.
"Until more information is gathered from the OEM (EATON) Paragon recommends the following:
"The reversing starters and reversing contactors are typically wired in a configuration that will electrically lock out one of the contactors when the other one is being energized to prevent both contactors from being energized at the same time. Therefore, the mechanical interlock is not required to prevent both contactors from being closed at the same time when the electrical interlock configuration is being implemented. In this scenario, the mechanical interlocks are not required and can be removed at the plant's discretion.
"Replacement mechanical interlocks may be ordered to replace the existing interlocks from the affected date code range if the plant application will not allow for removal.
"The motor control center cubicles or starter assemblies with date codes within the September 2014 through September 2018 range should be monitored to ensure that there is no binding during operation. It is possible that if the starter is found to bind during operation, the bound condition could be released by cycling the power to the starter. This action may release the bound condition and will allow the starter to operate."
Notified R1DO (Lilliendahl), R2DO (Miller), R3DO (Stone), R4DO (Werner), NMSS Events Notification, and Part 21 Group via email.
EN Revision Text: PART 21 - FAILURE OF SIZE 1 AND 2 FREEDOM SERIES FULL VOLTAGE REVERSING STARTERS
The following is a summary of information received from Paragon Energy Solutions:
On 3/29/2021, Dominion - North Anna Station has identified instances where size 1 and 2 starters have failed to function as expected in assemblies that were originally supplied by Nuclear Logistics LLC (NLI). The mechanical interlock exhibited binding that prevented the contactor from closing when energized. The identified failed starters are utilized in an application of operating Motor Operated Valves (MOV). This is an intermittent duty application.
The issue was identified on Eaton Starter Model AN56DN*, AN56GN*, CN55DN*, CN55GN* style starters and contactors with supplied date codes T4514 (week 45 of year 2014) and T4215 (week 42 of year 2015). Paragon is in the process of identifying the date codes to provide the specific information to the identified plants.
The following plants were supplied starters from September 2014 through October 2018: Beaver Valley, Columbia, Ergytech, Harris, Millstone, NEK KRSKO, North Anna, Prairie Island.
The component design that exhibited the failure was revised by the original equipment manufacturer (Eaton) in October 2018. There have been no reported failures of the interlock mechanism in vintages manufactured before September 2014 or after October 2018.
These recommendations are based on the specific application: The reversing starters and reversing contactors are typically wired in a configuration that will electrically lock out one of the contactors when the other one is being energized to prevent both contactors from being energized at the same time. Therefore, the mechanical interlock is not required to prevent both contactors from being closed at the same time when the electrical interlock configuration is being implemented. In this scenario, the mechanical interlocks are not required and can be removed.
The motor control centers that contain the mechanical interlock should be monitored to ensure that there is no binding during operation.
The evaluation being performed by Paragon is expected to be completed by May 29, 2021.
Tracy Bolt
Chief Nuclear Officer, CNO
817-284-0077
Paragon Energy Solutions, LLC
7410 Pebble Drive
Ft. Worth, TX 76118
* * * UPDATE ON 5/3/2021 AT 1559 FROM TRACY BOLT TO BRIAN LIN * * *
The following revision was received from Paragon Energy Solutions via email and corrects the identified date code and includes the size and serial number of the starter that failed:
The issue was identified on supplied Size 1, 73262-025-00028 (Date Code: T4515 - 45th week of 2015) and Size 2, 73262-028-00001 (Date Code: T4215 - 42nd week of 2015).
Notified R1DO (Young), R2DO (Miller), R3DO (Orlikowski), R4DO (Deese), NMSS Events Notification, and Part 21 Group via email.
* * * UPDATE ON 5/28/2021 AT 1558 FROM TRACY BOLT TO KERBY SCALES * * *
The following update (Interim Report) was received from Paragon Energy Solutions via email:
"Paragon is submitting this Interim Report since this condition is currently under evaluation but will not be completed within 60 days.
"Paragon is in communication with EATON, the OEM for the starters/contactors to determine the extent of condition. The evaluation is expected to be completed by June 30, 2021.
"It was determined that Dominion - Millstone should not be included in the list of affected plants. Millstone will be removed from the list in the final revision of P21-03302021."
Notified R1DO (Bower), R2DO (Miller), R3DO (Feliz-Adorno), R4DO (Gepford), NMSS Events Notification, and Part 21 Group via email.
* * * UPDATE ON 6/29/2021 AT 1658 EDT FROM TRACY BOLT TO BETHANY CECERE * * *
The following is a synopsis of an update (completion of the evaluation) received from Paragon Energy Solutions via email:
"Paragon has identified the date codes of the supplied starters and contactors to provide the specific information to the identified plants. This information has been provided directly to the specific plant." [Millstone was removed from the list of plants.]
"The component design that exhibited the failure was revised by the original equipment manufacturer (EATON) in September of 2014. The failed units were from Date Codes T4215 and T4515 which are in the 42nd and 45th weeks of 2015. In September 2018 the drawing was revised again. In discussions with the OEM the revision of the drawing was due to a change in material type and was not a result of binding issues.
"This condition has not been identified on assemblies manufactured after September 2018.
"Due to the number of starters that have been installed and in service without issue, it is highly unlikely that there is a defect within all the supplied starters in the date range of September 2014 through September 2018. To date, Paragon has been unable to obtain any conclusive information from EATON regarding the potential cause of the binding issue. One of the failed starters along with samples of binding and non-binding interlocks have been provided to EATON for them to perform their own analysis on the potential causes of the binding issue.
"Until more information is gathered from the OEM (EATON) Paragon recommends the following:
"The reversing starters and reversing contactors are typically wired in a configuration that will electrically lock out one of the contactors when the other one is being energized to prevent both contactors from being energized at the same time. Therefore, the mechanical interlock is not required to prevent both contactors from being closed at the same time when the electrical interlock configuration is being implemented. In this scenario, the mechanical interlocks are not required and can be removed at the plant's discretion.
"Replacement mechanical interlocks may be ordered to replace the existing interlocks from the affected date code range if the plant application will not allow for removal.
"The motor control center cubicles or starter assemblies with date codes within the September 2014 through September 2018 range should be monitored to ensure that there is no binding during operation. It is possible that if the starter is found to bind during operation, the bound condition could be released by cycling the power to the starter. This action may release the bound condition and will allow the starter to operate."
Notified R1DO (Lilliendahl), R2DO (Miller), R3DO (Stone), R4DO (Werner), NMSS Events Notification, and Part 21 Group via email.
Agreement State
Event Number: 55323
Rep Org: NORTH CAROLINA DIV OF RAD PROTECTIO
Licensee: Daimler Trucks
Region: 1
City: Cleveland State: NC
County:
License #: TBD
Agreement: Y
Docket:
NRC Notified By: Travis Cartoski
HQ OPS Officer: Thomas Kendzia
Licensee: Daimler Trucks
Region: 1
City: Cleveland State: NC
County:
License #: TBD
Agreement: Y
Docket:
NRC Notified By: Travis Cartoski
HQ OPS Officer: Thomas Kendzia
Notification Date: 06/23/2021
Notification Time: 11:28 [ET]
Event Date: 06/22/2021
Event Time: 00:00 [EDT]
Last Update Date: 06/23/2021
Notification Time: 11:28 [ET]
Event Date: 06/22/2021
Event Time: 00:00 [EDT]
Last Update Date: 06/23/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DEBOER, JOSEPH (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
DEBOER, JOSEPH (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 6/30/2021
EN Revision Text: AGREEMENT STATE REPORT - LOSS OF RADIOACTIVE MATERIAL
The following report was received from the North Carolina (NC) Division of Health Service Regulation via email:
"A NC General Licensee reports the loss of 8 NRD Advanced Static Control devices. Each device contained Po-210 with an activity of 10 mCi, each. General License: TBD as at the time of this report our General License Coordinator is currently unavailable. The licensee reports that the devices may have been inadvertently disposed of and their search continues at this time. This report remains incomplete but shall be updated to complete and close the record."
Advanced Static Control Device:
Manufacturer: NRD Inc.; Model: P-2021-Z705; S/N's: A2MB768, A2MB770, A2MB771, A2MB775, A2MB777, A2MB731, A2MB736, A2MB738
Sources Information:
Po-210 Activity .01 Ci each
NC Item Number: NC210010
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOSS OF RADIOACTIVE MATERIAL
The following report was received from the North Carolina (NC) Division of Health Service Regulation via email:
"A NC General Licensee reports the loss of 8 NRD Advanced Static Control devices. Each device contained Po-210 with an activity of 10 mCi, each. General License: TBD as at the time of this report our General License Coordinator is currently unavailable. The licensee reports that the devices may have been inadvertently disposed of and their search continues at this time. This report remains incomplete but shall be updated to complete and close the record."
Advanced Static Control Device:
Manufacturer: NRD Inc.; Model: P-2021-Z705; S/N's: A2MB768, A2MB770, A2MB771, A2MB775, A2MB777, A2MB731, A2MB736, A2MB738
Sources Information:
Po-210 Activity .01 Ci each
NC Item Number: NC210010
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf