Event Notification Report for June 16, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/15/2021 - 06/16/2021
Agreement State
Event Number: 55296
Rep Org: South Carolina Department of Health
Licensee: Prisma Health Greenville Memorial Hospital
Region: 1
City: Greenville State: SC
County:
License #: L275
Agreement: Y
Docket:
NRC Notified By: Andrew Roxburgh
HQ OPS Officer: Brian P. Smith
Licensee: Prisma Health Greenville Memorial Hospital
Region: 1
City: Greenville State: SC
County:
License #: L275
Agreement: Y
Docket:
NRC Notified By: Andrew Roxburgh
HQ OPS Officer: Brian P. Smith
Notification Date: 06/08/2021
Notification Time: 06:34 [ET]
Event Date: 06/04/2021
Event Time: 12:00 [EDT]
Last Update Date: 06/08/2021
Notification Time: 06:34 [ET]
Event Date: 06/04/2021
Event Time: 12:00 [EDT]
Last Update Date: 06/08/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
FERDAS, MARC (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
FERDAS, MARC (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 6/16/2021
EN Revision Text: AGREEMENT STATE REPORT - MEDICAL EVENT UNDERDOSE
The following event was received from the South Carolina Department of Health [the Department] via email:
"The licensee notified the Department on June 7, 2021 at 1300 [EDT] that it had determined at 1200 [EDT] a medical event had occurred because of a Y-90 Therasphere procedure that occurred on June 4, 2021. The licensee is reporting that the administered dose differed from the prescribed dose by more that 20 percent. The written directive specified that the patient was to be administered with 135.5 mCi of Y-90 Therasphere to the left lobe of the liver. During the procedure it was discovered that there was an apparent leak in the microcatheter. The dose delivered calculated to be less than 93 mCi. The remainder of the dose had leaked onto the floor. The licensee has decontaminated the room. The On-call Duty Officer is meeting with the licensee's Radiation Safety Officer on June 8, 2021 to investigate this incident. This is an initial notification and further updates will be forthcoming once the investigation is complete."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE REPORT - MEDICAL EVENT UNDERDOSE
The following event was received from the South Carolina Department of Health [the Department] via email:
"The licensee notified the Department on June 7, 2021 at 1300 [EDT] that it had determined at 1200 [EDT] a medical event had occurred because of a Y-90 Therasphere procedure that occurred on June 4, 2021. The licensee is reporting that the administered dose differed from the prescribed dose by more that 20 percent. The written directive specified that the patient was to be administered with 135.5 mCi of Y-90 Therasphere to the left lobe of the liver. During the procedure it was discovered that there was an apparent leak in the microcatheter. The dose delivered calculated to be less than 93 mCi. The remainder of the dose had leaked onto the floor. The licensee has decontaminated the room. The On-call Duty Officer is meeting with the licensee's Radiation Safety Officer on June 8, 2021 to investigate this incident. This is an initial notification and further updates will be forthcoming once the investigation is complete."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 55298
Rep Org: SC DEPT OF HEALTH & ENV CONTROL
Licensee: GS2 Engineering, Inc.
Region: 1
City: Columbia State: SC
County:
License #: 638
Agreement: Y
Docket:
NRC Notified By: Adam L. Gause
HQ OPS Officer: Lloyd Desotell
Licensee: GS2 Engineering, Inc.
Region: 1
City: Columbia State: SC
County:
License #: 638
Agreement: Y
Docket:
NRC Notified By: Adam L. Gause
HQ OPS Officer: Lloyd Desotell
Notification Date: 06/08/2021
Notification Time: 15:31 [ET]
Event Date: 06/02/2016
Event Time: 00:00 [EDT]
Last Update Date: 06/08/2021
Notification Time: 15:31 [ET]
Event Date: 06/02/2016
Event Time: 00:00 [EDT]
Last Update Date: 06/08/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
FERDAS, MARC (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
FERDAS, MARC (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 6/16/2021
EN Revision Text: AGREEMENT STATE REPORT - DAMAGED GAUGE
The following was received from the South Carolina Department of Health and Environmental Control via email:
"The South Carolina Department of Health and Environmental Control discovered a potential reportable event during a routine inspection of GS2 Engineering, Inc. on 06/08/2021. During the inspection it was discovered that a Troxler Model 3430 portable gauge (serial number 25345) [nominally 8 mCi Cs-137, 40 mCi Am-241:Be source] had been damaged and hit by a vehicle while on a temporary jobsite. The event appears to have occurred on 06/02/16 according to past utilization logs. The Troxler Model 3430 portable gauge has been stored at the licensee's facility within a locked cabinet. Survey results using a NDS ND-2000A survey instrument around the surface of the gauge indicated readings as high as 12 mR/hr. Survey results using a Ludlum 14-C survey instrument around the surface of the gauge indicated readings as high as 25 mR/hr. The gauge is secure within the licensee's storage area. This event is still under investigation by the South Carolina Department of Health and Environmental Control. "
EN Revision Text: AGREEMENT STATE REPORT - DAMAGED GAUGE
The following was received from the South Carolina Department of Health and Environmental Control via email:
"The South Carolina Department of Health and Environmental Control discovered a potential reportable event during a routine inspection of GS2 Engineering, Inc. on 06/08/2021. During the inspection it was discovered that a Troxler Model 3430 portable gauge (serial number 25345) [nominally 8 mCi Cs-137, 40 mCi Am-241:Be source] had been damaged and hit by a vehicle while on a temporary jobsite. The event appears to have occurred on 06/02/16 according to past utilization logs. The Troxler Model 3430 portable gauge has been stored at the licensee's facility within a locked cabinet. Survey results using a NDS ND-2000A survey instrument around the surface of the gauge indicated readings as high as 12 mR/hr. Survey results using a Ludlum 14-C survey instrument around the surface of the gauge indicated readings as high as 25 mR/hr. The gauge is secure within the licensee's storage area. This event is still under investigation by the South Carolina Department of Health and Environmental Control. "
Power Reactor
Event Number: 55306
Facility: Fort Calhoun
Region: 4 State: NE
Unit: [1] [] []
RX Type: (1) CE
NRC Notified By: Bill Rice
HQ OPS Officer: Jeffrey Whited
Region: 4 State: NE
Unit: [1] [] []
RX Type: (1) CE
NRC Notified By: Bill Rice
HQ OPS Officer: Jeffrey Whited
Notification Date: 06/15/2021
Notification Time: 15:38 [ET]
Event Date: 06/15/2021
Event Time: 12:30 [CDT]
Last Update Date: 06/15/2021
Notification Time: 15:38 [ET]
Event Date: 06/15/2021
Event Time: 12:30 [CDT]
Last Update Date: 06/15/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
JOSEY, JEFFREY (R4)
JOSEY, JEFFREY (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Defueled | 0 | Defueled |
EN Revision Imported Date: 6/17/2021
EN Revision Text: OFFSITE NOTIFICATION
"At 1230 CDT a report was made to the State of Nebraska Department of Environment and Energy (NDEE) based on the analytical report for soil samples from the area surrounding the removed FO-1, Emergency Diesel Generator Fuel Oil Storage Tank, and the removed FO-32, TSC/Security Fuel Oil Tank. The tanks were removed as part of Fort Calhoun Station decommissioning and soil samples were tested due to soil discoloration at the time the tanks were pulled. The soil contamination levels are from the historic use of the tank. The contamination levels are above the lab reporting limits and thereby reportable to the State of Nebraska Department of Environment and Energy. The NDEE will determine what, if any, remediation may be required. The state NDEE requested the District utilize their Spill Form because this is the simplest method of State notification for tanks exempted due to 40CFR280.10(c)(4).
"No active petroleum spills are in progress and appropriate remediation actions will be taken in accordance with Nebraska State regulation and guidance."
The licensee notified the NRC Region IV Office.
EN Revision Text: OFFSITE NOTIFICATION
"At 1230 CDT a report was made to the State of Nebraska Department of Environment and Energy (NDEE) based on the analytical report for soil samples from the area surrounding the removed FO-1, Emergency Diesel Generator Fuel Oil Storage Tank, and the removed FO-32, TSC/Security Fuel Oil Tank. The tanks were removed as part of Fort Calhoun Station decommissioning and soil samples were tested due to soil discoloration at the time the tanks were pulled. The soil contamination levels are from the historic use of the tank. The contamination levels are above the lab reporting limits and thereby reportable to the State of Nebraska Department of Environment and Energy. The NDEE will determine what, if any, remediation may be required. The state NDEE requested the District utilize their Spill Form because this is the simplest method of State notification for tanks exempted due to 40CFR280.10(c)(4).
"No active petroleum spills are in progress and appropriate remediation actions will be taken in accordance with Nebraska State regulation and guidance."
The licensee notified the NRC Region IV Office.
Agreement State
Event Number: 55301
Rep Org: LOUISIANA DEQ
Licensee: Premium Inspection and Testing
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-5838-L01 Amendment 100, AI# 210735
Agreement: Y
Docket:
NRC Notified By: Russell Clark
HQ OPS Officer: Donald Norwood
Licensee: Premium Inspection and Testing
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-5838-L01 Amendment 100, AI# 210735
Agreement: Y
Docket:
NRC Notified By: Russell Clark
HQ OPS Officer: Donald Norwood
Notification Date: 06/10/2021
Notification Time: 15:58 [ET]
Event Date: 06/10/2021
Event Time: 10:30 [CDT]
Last Update Date: 06/10/2021
Notification Time: 15:58 [ET]
Event Date: 06/10/2021
Event Time: 10:30 [CDT]
Last Update Date: 06/10/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DRAKE, JAMES (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
DRAKE, JAMES (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 6/17/2021
EN Revision Text: AGREEMENT STATE REPORT - FAILURE OF RADIOGRAPHY SOURCE TO FULLY RETRACT
The following information was received via E-mail:
"On June 10, 2021 at approximately 1030 CDT, a source hang out incident occurred while an industrial radiography crew was working at Shell Chemical, LP in Norco, St. Charles Parish, Louisiana. The radiography crew was working on the top level of a 100-foot tower located in the Geo-1 South unit.
"The crew observed after performing the exposure that the source could be cranked back almost all the way, except for approximately one half turn of the crank handle. Several more unsuccessful attempts were made by the crew to crank in the source. The source was then cranked out to the 4-HVL collimator and the crew expanded the restricted area boundary on the East side so that the entire boundary was at 2 mR/hr or below.
"The crew then contacted their site supervisor at approximately 1040 CDT, who in turn immediately contacted the Corporate Radiation Safety Officer (RSO). At approximately 1140 CDT, the source hang out incident was reported to the Department [Louisiana DEQ] Radiation Hotline by the Corporate RSO.
"A source retrieval trained radiography instructor was promptly tasked by the licensee with conducting a source retrieval. Six radiographers, including both of the crew members whose source was hung out, worked the restricted area boundary at ground level to prevent exposure to members of the public. After observing the placement of the collimator and source guide tube for approximately five seconds from five different locations at a distance of approximately 10 feet, the other source retrieval trained radiographer used a set of six-foot tongs to grab and shake the collimator and source guide tube. This loosened a bind in the source guide tube at the outlet nipple of the exposure device and permitted the source to be promptly afterwards retracted into the shielded position.
"The source was hung out for approximately three hours. The radiography instructor who conducted various observations of the guide tube in preparation for the retrieval received three mR of exposure and the other retrieval trained radiography instructor, who performed the source retrieval received one mR of exposure. An additional certified radiographer who also assisted in the retrieval operation received one mR of exposure. All other personnel on site for the licensee received less than one mR of exposure from the hung out source. No members of the public were exposed.
"The radiography exposure device was a QSA Model 880 Delta, device serial number, D13738. The source was Ir-192 with 55 Ci of activity. The source serial number was 30128M."
Louisiana Event Report ID No.: LA20210006
EN Revision Text: AGREEMENT STATE REPORT - FAILURE OF RADIOGRAPHY SOURCE TO FULLY RETRACT
The following information was received via E-mail:
"On June 10, 2021 at approximately 1030 CDT, a source hang out incident occurred while an industrial radiography crew was working at Shell Chemical, LP in Norco, St. Charles Parish, Louisiana. The radiography crew was working on the top level of a 100-foot tower located in the Geo-1 South unit.
"The crew observed after performing the exposure that the source could be cranked back almost all the way, except for approximately one half turn of the crank handle. Several more unsuccessful attempts were made by the crew to crank in the source. The source was then cranked out to the 4-HVL collimator and the crew expanded the restricted area boundary on the East side so that the entire boundary was at 2 mR/hr or below.
"The crew then contacted their site supervisor at approximately 1040 CDT, who in turn immediately contacted the Corporate Radiation Safety Officer (RSO). At approximately 1140 CDT, the source hang out incident was reported to the Department [Louisiana DEQ] Radiation Hotline by the Corporate RSO.
"A source retrieval trained radiography instructor was promptly tasked by the licensee with conducting a source retrieval. Six radiographers, including both of the crew members whose source was hung out, worked the restricted area boundary at ground level to prevent exposure to members of the public. After observing the placement of the collimator and source guide tube for approximately five seconds from five different locations at a distance of approximately 10 feet, the other source retrieval trained radiographer used a set of six-foot tongs to grab and shake the collimator and source guide tube. This loosened a bind in the source guide tube at the outlet nipple of the exposure device and permitted the source to be promptly afterwards retracted into the shielded position.
"The source was hung out for approximately three hours. The radiography instructor who conducted various observations of the guide tube in preparation for the retrieval received three mR of exposure and the other retrieval trained radiography instructor, who performed the source retrieval received one mR of exposure. An additional certified radiographer who also assisted in the retrieval operation received one mR of exposure. All other personnel on site for the licensee received less than one mR of exposure from the hung out source. No members of the public were exposed.
"The radiography exposure device was a QSA Model 880 Delta, device serial number, D13738. The source was Ir-192 with 55 Ci of activity. The source serial number was 30128M."
Louisiana Event Report ID No.: LA20210006
Agreement State
Event Number: 55302
Rep Org: CO Dept of Public Health & Env
Licensee: Huddleston-Berry Engineering and Testing, LLC
Region: 4
City: Grand Junction State: CO
County:
License #: CO 1107-01
Agreement: Y
Docket:
NRC Notified By: Carrie Romanchek
HQ OPS Officer: Donald Norwood
Licensee: Huddleston-Berry Engineering and Testing, LLC
Region: 4
City: Grand Junction State: CO
County:
License #: CO 1107-01
Agreement: Y
Docket:
NRC Notified By: Carrie Romanchek
HQ OPS Officer: Donald Norwood
Notification Date: 06/10/2021
Notification Time: 19:36 [ET]
Event Date: 06/10/2021
Event Time: 00:00 [MDT]
Last Update Date: 06/11/2021
Notification Time: 19:36 [ET]
Event Date: 06/10/2021
Event Time: 00:00 [MDT]
Last Update Date: 06/11/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
DRAKE, JAMES (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ROUNDTREE, CLIFF (ILTAB)
DRAKE, JAMES (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ROUNDTREE, CLIFF (ILTAB)
EN Revision Imported Date: 6/17/2021
EN Revision Text: AGREEMENT STATE REPORT - LOST PORTABLE MOISTURE / DENSITY GAUGE
The following information was received via E-mail:
"Event description: portable gauge came out of truck bed during transport.
"Event location: South Broadway and 340, Grand Junction, CO.
"Event type: Lost portable gauge, Troxler 3430 SN 26906, 333 MBq (9 mCi) of cesium-137 and 1.63 GBq (44 mCi) of americium-241:beryllium; or 2.44 MBq (66 microCi) of californium-252."
Colorado Event Report ID No.: Pending
* * * UPDATE ON JUNE 11, 2021 FROM PHILLIP PETERSON TO THOMAS HERRITY * * *
The following update was received via E-mail:
"The portable gauge reported lost by Colorado on 6/10/21 has been found. The gauge was found by an employee at the worksite where the gauge fell off the back of the truck and was secured. The licensee was notified and has recovered the gauge."
Notified R4DO (Drake) and NMSS Events Notification and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST PORTABLE MOISTURE / DENSITY GAUGE
The following information was received via E-mail:
"Event description: portable gauge came out of truck bed during transport.
"Event location: South Broadway and 340, Grand Junction, CO.
"Event type: Lost portable gauge, Troxler 3430 SN 26906, 333 MBq (9 mCi) of cesium-137 and 1.63 GBq (44 mCi) of americium-241:beryllium; or 2.44 MBq (66 microCi) of californium-252."
Colorado Event Report ID No.: Pending
* * * UPDATE ON JUNE 11, 2021 FROM PHILLIP PETERSON TO THOMAS HERRITY * * *
The following update was received via E-mail:
"The portable gauge reported lost by Colorado on 6/10/21 has been found. The gauge was found by an employee at the worksite where the gauge fell off the back of the truck and was secured. The licensee was notified and has recovered the gauge."
Notified R4DO (Drake) and NMSS Events Notification and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf