Event Notification Report for April 21, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/20/2021 - 04/21/2021
Part 21
Event Number: 55095
Rep Org: FLOWSERVE
Licensee: FLOWSERVE
Region: 1
City: Lynchburg State: VA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Tyler Thompson
HQ OPS Officer: Brian Lin
Licensee: FLOWSERVE
Region: 1
City: Lynchburg State: VA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Tyler Thompson
HQ OPS Officer: Brian Lin
Notification Date: 02/04/2021
Notification Time: 11:00 [ET]
Event Date: 12/09/2020
Event Time: 00:00 [EST]
Last Update Date: 04/20/2021
Notification Time: 11:00 [ET]
Event Date: 12/09/2020
Event Time: 00:00 [EST]
Last Update Date: 04/20/2021
Emergency Class: Non Emergency
10 CFR Section:
21.21(a)(2) - Interim Eval Of Deviation
10 CFR Section:
21.21(a)(2) - Interim Eval Of Deviation
Person (Organization):
DENTEL, GLENN (R1DO)
MILLER, MARK (R2DO)
RIEMER, KENNETH (R3DO)
AZUA, RAY (R4DO)
PART 21/50.55 REACTORS, - (EMAIL)
DENTEL, GLENN (R1DO)
MILLER, MARK (R2DO)
RIEMER, KENNETH (R3DO)
AZUA, RAY (R4DO)
PART 21/50.55 REACTORS, - (EMAIL)
EN Revision Imported Date: 4/21/2021
EN Revision Text: PART 21 REPORT - ACTUATOR FAILURE DUE TO LOOSE CAM PINS
The following is a summary of the report provided by the supplier:
Flowserve - Limitorque was informed that during testing of a SMB-0 actuator prior to installation, the actuator failed to return from the manual handwheel mode to motor operation mode. Site personnel removed the electric motor from the actuator and discovered that the worm shaft gear cam pin had become detached from the worm shaft clutch gear. The actuator was one of six identical actuators supplied to Ontario Power Generation by Limitorque in January 2020. Subsequent site inspection of five other actuators received on the order revealed that the cam pins were loose in the worm shaft clutch gear. The issue was discovered prior to placing any of the actuators into service. The defect was the result of improper assembly of the worm shaft clutch gear. The machinist manufacturing the component failed to complete the step require to permanently retain the cam pin in position.
Although no other occurrences of this issue have been reported, Flowserve is continuing to evaluate this issue regarding the potential extent of condition. Currently, there are no recommended actions for the nuclear plants concerning this Part 21 notification.
The supplier has not identified any affected plants at this time and continue to evaluate the extent of condition.
Part number containing the worm shaft clutch gear: 60-420-0130-1
Corrective Actions:
The six gears affected were returned to Limitorque for evaluation and replacement. All SMB worm shaft gears of similar design were placed on temporary quality assurance hold for enhanced inspection. No defective parts were found. All worm shaft gears currently being manufactured will have an additional quality control inspection point for proper cam pin installation.
Point of contact: Kyle Ramsey, Senior Product Engineer at Flowserve-Limitorque Actuation Systems, 5114 Woodall Road, Lynchburg, VA 24502, Office number: 434-522-4138
* * * UPDATE ON 4/20/2021 AT 1009 EDT FROM CHRIS SHAFFER TO BRIAN LIN * * *
Flowserve's investigation has concluded that the assembly error that resulted in the defect being reported was an isolated incident affecting the six parts identified below that were manufactured on a single work order in January 2020. No other gears were manufactured on that work order. Production records indicate that approximately 400 SMB-0 worm shaft clutch gears have been manufactured for nuclear and commercial applications in the past four years. No other instances of loose cam pins have been reported.
Notified R1DO (Arner), R2DO (Miller), R3DO (Peterson), R4DO (Azua), and Part 21 Reactors Group (email).
EN Revision Text: PART 21 REPORT - ACTUATOR FAILURE DUE TO LOOSE CAM PINS
The following is a summary of the report provided by the supplier:
Flowserve - Limitorque was informed that during testing of a SMB-0 actuator prior to installation, the actuator failed to return from the manual handwheel mode to motor operation mode. Site personnel removed the electric motor from the actuator and discovered that the worm shaft gear cam pin had become detached from the worm shaft clutch gear. The actuator was one of six identical actuators supplied to Ontario Power Generation by Limitorque in January 2020. Subsequent site inspection of five other actuators received on the order revealed that the cam pins were loose in the worm shaft clutch gear. The issue was discovered prior to placing any of the actuators into service. The defect was the result of improper assembly of the worm shaft clutch gear. The machinist manufacturing the component failed to complete the step require to permanently retain the cam pin in position.
Although no other occurrences of this issue have been reported, Flowserve is continuing to evaluate this issue regarding the potential extent of condition. Currently, there are no recommended actions for the nuclear plants concerning this Part 21 notification.
The supplier has not identified any affected plants at this time and continue to evaluate the extent of condition.
Part number containing the worm shaft clutch gear: 60-420-0130-1
Corrective Actions:
The six gears affected were returned to Limitorque for evaluation and replacement. All SMB worm shaft gears of similar design were placed on temporary quality assurance hold for enhanced inspection. No defective parts were found. All worm shaft gears currently being manufactured will have an additional quality control inspection point for proper cam pin installation.
Point of contact: Kyle Ramsey, Senior Product Engineer at Flowserve-Limitorque Actuation Systems, 5114 Woodall Road, Lynchburg, VA 24502, Office number: 434-522-4138
* * * UPDATE ON 4/20/2021 AT 1009 EDT FROM CHRIS SHAFFER TO BRIAN LIN * * *
Flowserve's investigation has concluded that the assembly error that resulted in the defect being reported was an isolated incident affecting the six parts identified below that were manufactured on a single work order in January 2020. No other gears were manufactured on that work order. Production records indicate that approximately 400 SMB-0 worm shaft clutch gears have been manufactured for nuclear and commercial applications in the past four years. No other instances of loose cam pins have been reported.
Notified R1DO (Arner), R2DO (Miller), R3DO (Peterson), R4DO (Azua), and Part 21 Reactors Group (email).
Non-Agreement State
Event Number: 55190
Rep Org: United States Steel
Licensee: United States Steel
Region: 3
City: Gary State: IN
County:
License #: 13-26104-03
Agreement: N
Docket:
NRC Notified By: ShaKeia Reese
HQ OPS Officer: Brian Lin
Licensee: United States Steel
Region: 3
City: Gary State: IN
County:
License #: 13-26104-03
Agreement: N
Docket:
NRC Notified By: ShaKeia Reese
HQ OPS Officer: Brian Lin
Notification Date: 04/13/2021
Notification Time: 16:02 [ET]
Event Date: 04/13/2021
Event Time: 07:45 [EDT]
Last Update Date: 04/13/2021
Notification Time: 16:02 [ET]
Event Date: 04/13/2021
Event Time: 07:45 [EDT]
Last Update Date: 04/13/2021
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
STOEDTER, KARLA (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
STOEDTER, KARLA (R3DO)
EN Revision Imported Date: 4/20/2021
EN Revision Text: STUCK SHUTTER
The following information was received from the licensee via email:
"At 0745 CDT, a Systems employee was in #14BF stock house performing lockout tagout procedures in preparation for an outage. As the employee was attempting to close the shutter on the north Berthold gauge, the handle broke leaving the shutter stuck in the open position. No personnel were exposed to the source. Under normal operating conditions the shutter remains open and doesn't pose an immediate hazard while following established procedures.
"Initial Corrective Actions:
- Performed a survey in the work area. No readings above background.
- Posted signage indicating that the shutter is inoperable, stuck in the open position, and informing employees not to enter.
- Contact manufacturer representative (Radiametrics) to schedule assessment and repairs."
The Berthold gauge contas a 300 milliCurie Am-241/Be source.
EN Revision Text: STUCK SHUTTER
The following information was received from the licensee via email:
"At 0745 CDT, a Systems employee was in #14BF stock house performing lockout tagout procedures in preparation for an outage. As the employee was attempting to close the shutter on the north Berthold gauge, the handle broke leaving the shutter stuck in the open position. No personnel were exposed to the source. Under normal operating conditions the shutter remains open and doesn't pose an immediate hazard while following established procedures.
"Initial Corrective Actions:
- Performed a survey in the work area. No readings above background.
- Posted signage indicating that the shutter is inoperable, stuck in the open position, and informing employees not to enter.
- Contact manufacturer representative (Radiametrics) to schedule assessment and repairs."
The Berthold gauge contas a 300 milliCurie Am-241/Be source.
Agreement State
Event Number: 55192
Rep Org: WA OFFICE OF RADIATION PROTECTION
Licensee: University of Washington
Region: 4
City: Seattle State: WA
County:
License #: C001
Agreement: Y
Docket:
NRC Notified By: Tristan Hay
HQ OPS Officer: Joanna Bridge
Licensee: University of Washington
Region: 4
City: Seattle State: WA
County:
License #: C001
Agreement: Y
Docket:
NRC Notified By: Tristan Hay
HQ OPS Officer: Joanna Bridge
Notification Date: 04/14/2021
Notification Time: 13:15 [ET]
Event Date: 01/01/1900
Event Time: 00:00 [PDT]
Last Update Date: 04/14/2021
Notification Time: 13:15 [ET]
Event Date: 01/01/1900
Event Time: 00:00 [PDT]
Last Update Date: 04/14/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
PICK, GREG (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
PICK, GREG (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 4/20/2021
EN Revision Text: AGREEMENT STATE REPORT - PATIENT UNDERDOSE
The following information was received from the Washington State Department of Health:
"University of Washington broad scope license C001 reported a medical event. The event involves y-90 microspheres contained in two vials of different activity. Vial A and Vial B were to be delivered to different treatment sites. However, the vials were mixed up and the lower activity vial was delivered to the wrong site, the Authorized User (AU) realized it was the wrong vial and did not inject the second vial. This resulted in an underdose of more than 20 percent. A full report is expected in 15 days and will be forwarded."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE REPORT - PATIENT UNDERDOSE
The following information was received from the Washington State Department of Health:
"University of Washington broad scope license C001 reported a medical event. The event involves y-90 microspheres contained in two vials of different activity. Vial A and Vial B were to be delivered to different treatment sites. However, the vials were mixed up and the lower activity vial was delivered to the wrong site, the Authorized User (AU) realized it was the wrong vial and did not inject the second vial. This resulted in an underdose of more than 20 percent. A full report is expected in 15 days and will be forwarded."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 55193
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: Columbia Hospital At Medical City Dallas
Region: 4
City: Dallas State: TX
County:
License #: L 01976
Agreement: Y
Docket:
NRC Notified By: Randal Redd
HQ OPS Officer: Joanna Bridge
Licensee: Columbia Hospital At Medical City Dallas
Region: 4
City: Dallas State: TX
County:
License #: L 01976
Agreement: Y
Docket:
NRC Notified By: Randal Redd
HQ OPS Officer: Joanna Bridge
Notification Date: 04/14/2021
Notification Time: 13:15 [ET]
Event Date: 04/14/2021
Event Time: 08:45 [CDT]
Last Update Date: 04/14/2021
Notification Time: 13:15 [ET]
Event Date: 04/14/2021
Event Time: 08:45 [CDT]
Last Update Date: 04/14/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
PICK, GREG (R4DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
RIVERA-CAPELLA, GRETCHEN (NMSS DAY)
PICK, GREG (R4DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
RIVERA-CAPELLA, GRETCHEN (NMSS DAY)
EN Revision Imported Date: 4/20/2021
EN Revision Text: AGREEMENT STATE REPORT - PATIENT RECEIVES WRONG DOSE
The following was received via e-mail from the State of Texas:
"On April 14, 2021, the licensee reported that a patient who was to receive 200 micro Ci of I-123 as a diagnostic procedure instead received 150 milli Ci I-131. The patient apparently left the hospital but is on their way back to receive [potassium iodine, (KI)] KI treatment and will remain in the hospital. The licensee will conduct investigation into how incident occurred and what the dose to the patient was.
"Additional information will be provided as it is received in accordance with SA-300.
"Texas Incident #: 9840"
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE REPORT - PATIENT RECEIVES WRONG DOSE
The following was received via e-mail from the State of Texas:
"On April 14, 2021, the licensee reported that a patient who was to receive 200 micro Ci of I-123 as a diagnostic procedure instead received 150 milli Ci I-131. The patient apparently left the hospital but is on their way back to receive [potassium iodine, (KI)] KI treatment and will remain in the hospital. The licensee will conduct investigation into how incident occurred and what the dose to the patient was.
"Additional information will be provided as it is received in accordance with SA-300.
"Texas Incident #: 9840"
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 55194
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: Acuren Inspection INC
Region: 4
City: La Porte State: TX
County:
License #: L 01774
Agreement: Y
Docket:
NRC Notified By: Karen Blanchard
HQ OPS Officer: Joanna Bridge
Licensee: Acuren Inspection INC
Region: 4
City: La Porte State: TX
County:
License #: L 01774
Agreement: Y
Docket:
NRC Notified By: Karen Blanchard
HQ OPS Officer: Joanna Bridge
Notification Date: 04/14/2021
Notification Time: 17:44 [ET]
Event Date: 04/14/2021
Event Time: 00:00 [CDT]
Last Update Date: 04/14/2021
Notification Time: 17:44 [ET]
Event Date: 04/14/2021
Event Time: 00:00 [CDT]
Last Update Date: 04/14/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
PICK, GREG (R4DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
PICK, GREG (R4DO)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
EN Revision Imported Date: 4/20/2021
EN Revision Text: AGREEMENT STATE - BROKEN RADIOGRAPHY CAMERA
The following was received via e-mail from the Texas Department of State Health Services:
"On April 14, 2021, the licensee reported to the agency [Texas Department of State Health Services] that one of its crews had been unable to retract a source while working at a temporary job site. They were using a QSA Delta 880 exposure device with a 96.7 curie iridium-192 source. The radiographers were cranking in the source and it did not feel right but it retracted and locked in inside the camera. They performed a survey of the camera and guide tube and found the source was in the fully shielded position. They cranked out for the next shot without issue but when they attempted to retract the source it was no longer on the end of the drive cable. The radiographers set a barricade and called the radiation safety officer (RSO). The RSO responded and performed a source retrieval. His electronic dosimeter indicated he received 70 mrem and there were no other exposures as a result of this event. The RSO reported that the drive cable had broken below the shank. The equipment will be sent to the manufacturer for evaluation. More information will be provided as it is obtained in accordance with SA-300.
"Equipment information:
QSA Delta 880 exposure device SN: D8849
96.7 curie iridium-192 source SN: 30413M
"Texas Incident no.: 9841"
EN Revision Text: AGREEMENT STATE - BROKEN RADIOGRAPHY CAMERA
The following was received via e-mail from the Texas Department of State Health Services:
"On April 14, 2021, the licensee reported to the agency [Texas Department of State Health Services] that one of its crews had been unable to retract a source while working at a temporary job site. They were using a QSA Delta 880 exposure device with a 96.7 curie iridium-192 source. The radiographers were cranking in the source and it did not feel right but it retracted and locked in inside the camera. They performed a survey of the camera and guide tube and found the source was in the fully shielded position. They cranked out for the next shot without issue but when they attempted to retract the source it was no longer on the end of the drive cable. The radiographers set a barricade and called the radiation safety officer (RSO). The RSO responded and performed a source retrieval. His electronic dosimeter indicated he received 70 mrem and there were no other exposures as a result of this event. The RSO reported that the drive cable had broken below the shank. The equipment will be sent to the manufacturer for evaluation. More information will be provided as it is obtained in accordance with SA-300.
"Equipment information:
QSA Delta 880 exposure device SN: D8849
96.7 curie iridium-192 source SN: 30413M
"Texas Incident no.: 9841"
Power Reactor
Event Number: 55200
Facility: Browns Ferry
Region: 2 State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: Wesley Conkle
HQ OPS Officer: Donald Norwood
Region: 2 State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: Wesley Conkle
HQ OPS Officer: Donald Norwood
Notification Date: 04/20/2021
Notification Time: 15:36 [ET]
Event Date: 04/19/2021
Event Time: 18:10 [CDT]
Last Update Date: 04/20/2021
Notification Time: 15:36 [ET]
Event Date: 04/19/2021
Event Time: 18:10 [CDT]
Last Update Date: 04/20/2021
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
MILLER, MARK (R2)
FFD GROUP, (EMAIL)
MILLER, MARK (R2)
FFD GROUP, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | N | 0 | Hot Shutdown | 0 | Hot Shutdown |
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
FITNESS-FOR-DUTY REPORT - EMPLOYEE SUPERVISOR CONFIRMED POSITIVE FOR ALCOHOL
A non-licensed, employee supervisor had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the plant has been terminated.
The licensee notified the NRC Resident Inspector.
A non-licensed, employee supervisor had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the plant has been terminated.
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 55201
Facility: Catawba
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Terry Odoms
HQ OPS Officer: Brian Lin
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Terry Odoms
HQ OPS Officer: Brian Lin
Notification Date: 04/21/2021
Notification Time: 02:37 [ET]
Event Date: 04/20/2021
Event Time: 22:30 [EDT]
Last Update Date: 04/21/2021
Notification Time: 02:37 [ET]
Event Date: 04/20/2021
Event Time: 22:30 [EDT]
Last Update Date: 04/21/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
MILLER, MARK (R2)
MILLER, MARK (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Refueling | 0 | Refueling |
REACTOR COOLANT SYSTEM (RCS) PRESSURE BOUNDARY DEGRADED
"During the performance of reactor vessel closure head (RVCH) examinations, at 2230 EDT on April 20, 2021, it was determined that the Unit 2 RVCH penetration nozzle number 74 did not meet the requirements of 10CFR50.55a(g)(6)(ii)(D) and ASME code case N-729-6 . All other RVCH penetration examinations have been completed per 10CFR50.55a(g)(6)(ii)(D) and ASME code case N-729-6 with no other relevant indications identified. The condition of the Unit 2 reactor vessel head penetration nozzle number 74 will be resolved prior to re-installation of the Unit 2 RVCH. This event is being reported as an eight-hour, non-emergency notification per 10CFR50.72(b)(3)(ii)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
"During the performance of reactor vessel closure head (RVCH) examinations, at 2230 EDT on April 20, 2021, it was determined that the Unit 2 RVCH penetration nozzle number 74 did not meet the requirements of 10CFR50.55a(g)(6)(ii)(D) and ASME code case N-729-6 . All other RVCH penetration examinations have been completed per 10CFR50.55a(g)(6)(ii)(D) and ASME code case N-729-6 with no other relevant indications identified. The condition of the Unit 2 reactor vessel head penetration nozzle number 74 will be resolved prior to re-installation of the Unit 2 RVCH. This event is being reported as an eight-hour, non-emergency notification per 10CFR50.72(b)(3)(ii)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
Power Reactor
Event Number: 55202
Facility: Pilgrim
Region: 1 State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: David Noyes
HQ OPS Officer: Brian Lin
Region: 1 State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: David Noyes
HQ OPS Officer: Brian Lin
Notification Date: 04/21/2021
Notification Time: 09:45 [ET]
Event Date: 04/21/2021
Event Time: 07:52 [EDT]
Last Update Date: 04/21/2021
Notification Time: 09:45 [ET]
Event Date: 04/21/2021
Event Time: 07:52 [EDT]
Last Update Date: 04/21/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
ARNER, FRANK (R1)
ARNER, FRANK (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Defueled | 0 | Defueled |
OFFSITE NOTIFICATION TO THE COMMONWEALTH OF MASSACHUSETTS
On April 21, 2021, at 0752 hours (EDT), an offsite notification was made to the Commonwealth of Massachusetts Department of Environmental Protection (MADEP) in accordance with Regulation 310 CMR 40.0000: Massachusetts Contingency Plan (MCP). The notification documents non-radiological contaminants found above reportable concentrations in select samples collected during site characterization efforts. The reported reportable concentrations were slightly above reporting limits in a soil sample for Per and Polyfluoroalkyl Substances (PFAS), two groundwater sampling locations for PFAS, and isolated instances of metals in groundwater including Arsenic, Vanadium, Lead, Antimony, Beryllium, Cadmium, Chromium, Nickel, and Thallium. This report is being submitted in accordance with 10CFR50.72(b)(2)(xi) based on notification being made to another government agency. Concentrations above reporting limits have been entered into the site's corrective action program. As per MCP, the site will proceed with requirements to implement the phased MCP process. This condition does not represent a threat to station personnel or to members of the general public.
On April 21, 2021, at 0752 hours (EDT), an offsite notification was made to the Commonwealth of Massachusetts Department of Environmental Protection (MADEP) in accordance with Regulation 310 CMR 40.0000: Massachusetts Contingency Plan (MCP). The notification documents non-radiological contaminants found above reportable concentrations in select samples collected during site characterization efforts. The reported reportable concentrations were slightly above reporting limits in a soil sample for Per and Polyfluoroalkyl Substances (PFAS), two groundwater sampling locations for PFAS, and isolated instances of metals in groundwater including Arsenic, Vanadium, Lead, Antimony, Beryllium, Cadmium, Chromium, Nickel, and Thallium. This report is being submitted in accordance with 10CFR50.72(b)(2)(xi) based on notification being made to another government agency. Concentrations above reporting limits have been entered into the site's corrective action program. As per MCP, the site will proceed with requirements to implement the phased MCP process. This condition does not represent a threat to station personnel or to members of the general public.