Event Notification Report for March 14, 2021

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/13/2021 - 03/14/2021

EVENT NUMBERS
55138
Power Reactor
Event Number: 55138
Facility: Arkansas Nuclear
Region: 4     State: AR
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: Justin Duke
HQ OPS Officer: Thomas Herrity
Notification Date: 03/14/2021
Notification Time: 18:05 [ET]
Event Date: 03/14/2021
Event Time: 13:15 [CST]
Last Update Date: 03/14/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
JEFFREY JOSEY (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 100 Power Operation 0 Hot Standby
Event Text
EN Revision Imported Date: 4/13/2021

EN Revision Text: MANUAL TRIP DUE TO LOSS BUS VOLTAGE

"On March 14, 2021, at 1315 CDT, Arkansas Nuclear One, Unit 1(ANO-1) was manually tripped due to degraded voltage and momentary loss of the A-2, non-vital 4160 V Bus in accordance with Abnormal Operating Procedure. All control rods fully inserted. Degraded voltage of the A-2 non-vital 4160 V Bus resulted in de-energizing the A-4 vital 4160 V Bus. Emergency Diesel Generator No. 2, K-4B, started automatically and is currently powering the A-4 vital 4160 V Bus. All other Vital and Non-Vital Buses transferred power automatically to the Startup Transformer No. 1. Offsite power remains energized and available for ANO-1. All other systems responded as designed. The loss of the A-2 Non-Vital Bus is still under investigation.

"ANO-1 is currently stable in MODE 3 (Hot Standby), maintaining pressure and temperature with Main Feedwater pumps and steaming to the Condenser.

"There are no indications of a radiological release on either unit as a result of this event.

"This report satisfies the reporting criteria of both 10 CFR 50.72(b)(2)(iv)(B) for the Reactor Protection System actuation and 10 CFR 50.72(b)(3)(iv)(A) for the actuation of the Emergency Diesel Generator.

"The Licensee has notified the NRC Senior Resident Inspector."