Event Notification Report for January 26, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/25/2021 - 01/26/2021
Agreement State
Event Number: 55069
Rep Org: VIRGINIA RAD MATERIALS PROGRAM
Licensee: Quest Diagnostic Nichols Institute
Region: 1
City: Chantilly State: VA
County: Fairfax
License #: 107-401-1
Agreement: Y
Docket:
NRC Notified By: Asfaw Fenta
HQ OPS Officer: Brian Lin
Licensee: Quest Diagnostic Nichols Institute
Region: 1
City: Chantilly State: VA
County: Fairfax
License #: 107-401-1
Agreement: Y
Docket:
NRC Notified By: Asfaw Fenta
HQ OPS Officer: Brian Lin
Notification Date: 01/15/2021
Notification Time: 15:47 [ET]
Event Date: 01/05/2021
Event Time: 00:00 [EST]
Last Update Date: 01/15/2021
Notification Time: 15:47 [ET]
Event Date: 01/05/2021
Event Time: 00:00 [EST]
Last Update Date: 01/15/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
JON LILLIENDAHL (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
JON LILLIENDAHL (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
AGREEMENT STATE REPORT - MISSING SOURCE
The following information was received from the Commonwealth of Virginia via email:
"On January 5, 2021, the licensee reported that 34.02 microCuries of I -125 Aqueous Solution (Musk Tracer) was lost. The source was received on December 8, 2020. The licensee's technologist opened the package and checked if it needed to be refrigerated. The technologist verified the source was in the package and determined that the source did not need to be refrigerated. Then the technologist left the source in the package on the floor with the other items in the inventory area. Upon review of the receipt log of radioactive materials, it was noted that this shipment (package) was never logged-in, whereas other products received that day were included in the log, and the source could not be located. On 12/11/2020, the RSO [Radiation Safety Officer] was notified about the possible loss of the package. A search was conducted in the facility, but the licensee was unable to locate the source. The Facilities Department was alerted that there was a missing shipment (source), but five days had already passed. The licensee stated that it was too late to go through the dumpsters. The licensee believed that the package was unknowingly disposed of in a dumpster. However, the search is continuing. The licensee will submit the possible maximum public dose exposure from this source. This report will be updated when the licensee submits their final investigation report."
Virginia report no.: VA210001
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received from the Commonwealth of Virginia via email:
"On January 5, 2021, the licensee reported that 34.02 microCuries of I -125 Aqueous Solution (Musk Tracer) was lost. The source was received on December 8, 2020. The licensee's technologist opened the package and checked if it needed to be refrigerated. The technologist verified the source was in the package and determined that the source did not need to be refrigerated. Then the technologist left the source in the package on the floor with the other items in the inventory area. Upon review of the receipt log of radioactive materials, it was noted that this shipment (package) was never logged-in, whereas other products received that day were included in the log, and the source could not be located. On 12/11/2020, the RSO [Radiation Safety Officer] was notified about the possible loss of the package. A search was conducted in the facility, but the licensee was unable to locate the source. The Facilities Department was alerted that there was a missing shipment (source), but five days had already passed. The licensee stated that it was too late to go through the dumpsters. The licensee believed that the package was unknowingly disposed of in a dumpster. However, the search is continuing. The licensee will submit the possible maximum public dose exposure from this source. This report will be updated when the licensee submits their final investigation report."
Virginia report no.: VA210001
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55070
Rep Org: Louisiana Dept of Enviro Quality
Licensee: Alpha-Omega Services, Inc.
Region: 4
City: Vinton State: LA
County:
License #: LA-10025-L01, Amd 33, AI #30898
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Bethany Cecere
Licensee: Alpha-Omega Services, Inc.
Region: 4
City: Vinton State: LA
County:
License #: LA-10025-L01, Amd 33, AI #30898
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Bethany Cecere
Notification Date: 01/15/2021
Notification Time: 17:21 [ET]
Event Date: 01/15/2021
Event Time: 15:30 [CST]
Last Update Date: 01/15/2021
Notification Time: 17:21 [ET]
Event Date: 01/15/2021
Event Time: 15:30 [CST]
Last Update Date: 01/15/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
NEIL O'KEEFE (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
NEIL O'KEEFE (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
AGREEMENT STATE REPORT - LOST SOURCE IN TRANSIT
The following was received from the State of Louisiana, Department of Environmental Quality:
"On January 05, 2021, [the Radiation Safety Officer] (RSO) dropped off seventeen sources to the common carrier for shipment to various locations. Alpha-Omega contacted the Louisiana Department of Environmental Quality / Emergency Response Services Division / Radiation Section [at 1530 CST on 1/15/21] to report that a High Dose Rate (HDR) Ir-192 source was lost in transit with the common carrier. The source was being shipped to Mid-Columbia Medical Center, The Dalles, OR. The source serial number is D36R0392. The activity of the Ir-192 source on 1/5/21 was 10.568 Ci (391.016 GBq) when it was shipped. The current activity on 1/15/21 is 9.626 Ci (356.162 GBq). The common carrier does not show this source being tracked or received."
LA Event Report ID No.: LA 20210001
THIS MATERIAL EVENT CONTAINS A "CATEGORY 3" LEVEL OF RADIOACTIVE MATERIAL
Category 3 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for some hours. It could possibly - although it is unlikely - be fatal to be close to this amount of unshielded radioactive material for a period of days to weeks. These sources are typically used in practices such as fixed industrial gauges involving high activity sources (for example: level gauges, dredger gauges, conveyor gauges and spinning pipe gauges) and well logging. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Note: This device is assigned an IAEA Category 3 value based on the actual radioactivity of the source, not on the device type. (Reference IAEA RG-G-1.9)
The following was received from the State of Louisiana, Department of Environmental Quality:
"On January 05, 2021, [the Radiation Safety Officer] (RSO) dropped off seventeen sources to the common carrier for shipment to various locations. Alpha-Omega contacted the Louisiana Department of Environmental Quality / Emergency Response Services Division / Radiation Section [at 1530 CST on 1/15/21] to report that a High Dose Rate (HDR) Ir-192 source was lost in transit with the common carrier. The source was being shipped to Mid-Columbia Medical Center, The Dalles, OR. The source serial number is D36R0392. The activity of the Ir-192 source on 1/5/21 was 10.568 Ci (391.016 GBq) when it was shipped. The current activity on 1/15/21 is 9.626 Ci (356.162 GBq). The common carrier does not show this source being tracked or received."
LA Event Report ID No.: LA 20210001
THIS MATERIAL EVENT CONTAINS A "CATEGORY 3" LEVEL OF RADIOACTIVE MATERIAL
Category 3 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for some hours. It could possibly - although it is unlikely - be fatal to be close to this amount of unshielded radioactive material for a period of days to weeks. These sources are typically used in practices such as fixed industrial gauges involving high activity sources (for example: level gauges, dredger gauges, conveyor gauges and spinning pipe gauges) and well logging. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Note: This device is assigned an IAEA Category 3 value based on the actual radioactivity of the source, not on the device type. (Reference IAEA RG-G-1.9)
Agreement State
Event Number: 55072
Rep Org: GEORGIA RADIOACTIVE MATERIAL PGM
Licensee: Atlanta Heart Associates, P.C.
Region: 1
City: Stockbridge State: GA
County:
License #: GA-1721-1
Agreement: Y
Docket:
NRC Notified By: Shatavia Walker
HQ OPS Officer: Donald Norwood
Licensee: Atlanta Heart Associates, P.C.
Region: 1
City: Stockbridge State: GA
County:
License #: GA-1721-1
Agreement: Y
Docket:
NRC Notified By: Shatavia Walker
HQ OPS Officer: Donald Norwood
Notification Date: 01/19/2021
Notification Time: 14:46 [ET]
Event Date: 01/04/2021
Event Time: 00:00 [EST]
Last Update Date: 01/19/2021
Notification Time: 14:46 [ET]
Event Date: 01/04/2021
Event Time: 00:00 [EST]
Last Update Date: 01/19/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
BICKETT, BRICE (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
BICKETT, BRICE (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
AGREEMENT STATE REPORT - LEAKING CALIBRATION SOURCE
The following information was received via E-mail:
"On 1/4/2021, a leak test was performed on an Isotope Products Laboratories Cs-137 sealed source vial, serial number 1074-19-20, used as a dose calibrator constancy source. The current calculated activity at the time of the leak test measured 147.49 microcuries from the reference date of 9/1/2004. The measured results of the leak test revealed an activity of 0.012 microcuries on 1/4/2021 at 1253 EST.
"The Cs-137 sealed source was promptly sealed within its lead container and firmly taped closed. This taped pig was then placed inside of several nitrile gloves, which were also generously taped closed, adorned with radioactive material stickers and the source was placed into the facility's radioactive material waste storage closet. The visible label includes the isotope, date of storage, current activity, and signature of the individual who stored it. The same documentation was also entered into the sealed source inventory. The RSO was then promptly notified of the event.
"The source leak test was conducted by Alliance Medical Physics."
Georgia Incident Number: 35
The following information was received via E-mail:
"On 1/4/2021, a leak test was performed on an Isotope Products Laboratories Cs-137 sealed source vial, serial number 1074-19-20, used as a dose calibrator constancy source. The current calculated activity at the time of the leak test measured 147.49 microcuries from the reference date of 9/1/2004. The measured results of the leak test revealed an activity of 0.012 microcuries on 1/4/2021 at 1253 EST.
"The Cs-137 sealed source was promptly sealed within its lead container and firmly taped closed. This taped pig was then placed inside of several nitrile gloves, which were also generously taped closed, adorned with radioactive material stickers and the source was placed into the facility's radioactive material waste storage closet. The visible label includes the isotope, date of storage, current activity, and signature of the individual who stored it. The same documentation was also entered into the sealed source inventory. The RSO was then promptly notified of the event.
"The source leak test was conducted by Alliance Medical Physics."
Georgia Incident Number: 35
Non-Agreement State
Event Number: 55074
Rep Org: US Steel Great Lakes Works
Licensee: US Steel Great Lakes Works
Region: 3
City: Ecorse State: MI
County:
License #: 21-10459-01
Agreement: N
Docket:
NRC Notified By: Robin Birk
HQ OPS Officer: Joanna Bridge
Licensee: US Steel Great Lakes Works
Region: 3
City: Ecorse State: MI
County:
License #: 21-10459-01
Agreement: N
Docket:
NRC Notified By: Robin Birk
HQ OPS Officer: Joanna Bridge
Notification Date: 01/19/2021
Notification Time: 17:36 [ET]
Event Date: 01/19/2021
Event Time: 00:00 [EST]
Last Update Date: 01/19/2021
Notification Time: 17:36 [ET]
Event Date: 01/19/2021
Event Time: 00:00 [EST]
Last Update Date: 01/19/2021
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
PETERSON, HIRONORI (R3)
PETERSON, HIRONORI (R3)
NON-AGREEMENT STATE REPORT - SHUTTER NOT FUNCTIONING CORRECTLY
The following is a summary of a call received from the licensee:
The licensee reported a shutter stuck open on a DMC-19 gauge, s/n: 7759LX, with a 1,000 microCi AM-241 source. The shutter is currently closed and locked. There were no overexposures. Global Gauge was working on the shutter and is expected to conduct repairs on 01/20/2021.
The following is a summary of a call received from the licensee:
The licensee reported a shutter stuck open on a DMC-19 gauge, s/n: 7759LX, with a 1,000 microCi AM-241 source. The shutter is currently closed and locked. There were no overexposures. Global Gauge was working on the shutter and is expected to conduct repairs on 01/20/2021.
Agreement State
Event Number: 55075
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: Langan Engineering and Environmental Services, Inc.
Region: 4
City: Oakland State: CA
County:
License #: 8224-43
Agreement: Y
Docket:
NRC Notified By: Nika Hewadikaram
HQ OPS Officer: Donald Norwood
Licensee: Langan Engineering and Environmental Services, Inc.
Region: 4
City: Oakland State: CA
County:
License #: 8224-43
Agreement: Y
Docket:
NRC Notified By: Nika Hewadikaram
HQ OPS Officer: Donald Norwood
Notification Date: 01/19/2021
Notification Time: 21:17 [ET]
Event Date: 01/15/2021
Event Time: 00:00 [PST]
Last Update Date: 01/19/2021
Notification Time: 21:17 [ET]
Event Date: 01/15/2021
Event Time: 00:00 [PST]
Last Update Date: 01/19/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
WARNICK, GREG (R4)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
CNSNS (MEXICO) (EMAIL)
WARNICK, GREG (R4)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
CNSNS (MEXICO) (EMAIL)
AGREEMENT STATE REPORT - STOLEN MOISTURE / DENSITY GAUGES
The following information was received via E-mail:
"On 1/19/21, The California Office of Emergency Services (Cal OES) contacted the Radiologic Health Branch (RHB) to report an incident involving five stolen moisture / density gauges. The initial report to Cal OES was made by the Santa Clara Fire Department. Upon receipt of the Cal OES incident report, RHB contacted the licensee and learned the following:
"The licensee became aware of this theft on 1/19/21, when one of their staff members attempted to collect a gauge from the authorized storage unit located at 3033 Lafayette Street, Unit A133, in Santa Clara, CA. The licensee had five gauges stored at this location.
"According to the Public Storage facility personnel, the theft occurred late at night on Friday, 1/15/2021, when eight units were burglarized that day. The licensee stated that they did not receive any notification from the storage unit personnel regarding the theft on Friday. On 01/19/21, the licensee notified the Santa Clara Police Department of the theft (case number: 21-115042) and dispatchers were able to recover five transport cases near De La Cruz and Hwy 101 in Santa Clara, but the gauges were all missing.
"The gauges that were stolen include:
"1. CPN International MC-3, S/N M380709085, 50mCi of AmBe 241 and 10mCi of Cs 137
2. InstroTek MCE-3, S/N 30380, 50mCi of AmBe 241 and 10mCi of Cs 137
3. InstroTek MCE-3, S/N 30958, 50mCi of AmBe 241 and 10mCi of Cs 137
4. InstroTek Explorer 3500, S/N 3375, 44mCi of AmBe 241 and 11mCi of Cs 137
5. InstroTek Explorer 3500, S/N 3826, 44mCi of AmBe 241 and 11mCi of Cs 137
"RHB will be following up on this investigation."
California 5010 Number: 011921
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received via E-mail:
"On 1/19/21, The California Office of Emergency Services (Cal OES) contacted the Radiologic Health Branch (RHB) to report an incident involving five stolen moisture / density gauges. The initial report to Cal OES was made by the Santa Clara Fire Department. Upon receipt of the Cal OES incident report, RHB contacted the licensee and learned the following:
"The licensee became aware of this theft on 1/19/21, when one of their staff members attempted to collect a gauge from the authorized storage unit located at 3033 Lafayette Street, Unit A133, in Santa Clara, CA. The licensee had five gauges stored at this location.
"According to the Public Storage facility personnel, the theft occurred late at night on Friday, 1/15/2021, when eight units were burglarized that day. The licensee stated that they did not receive any notification from the storage unit personnel regarding the theft on Friday. On 01/19/21, the licensee notified the Santa Clara Police Department of the theft (case number: 21-115042) and dispatchers were able to recover five transport cases near De La Cruz and Hwy 101 in Santa Clara, but the gauges were all missing.
"The gauges that were stolen include:
"1. CPN International MC-3, S/N M380709085, 50mCi of AmBe 241 and 10mCi of Cs 137
2. InstroTek MCE-3, S/N 30380, 50mCi of AmBe 241 and 10mCi of Cs 137
3. InstroTek MCE-3, S/N 30958, 50mCi of AmBe 241 and 10mCi of Cs 137
4. InstroTek Explorer 3500, S/N 3375, 44mCi of AmBe 241 and 11mCi of Cs 137
5. InstroTek Explorer 3500, S/N 3826, 44mCi of AmBe 241 and 11mCi of Cs 137
"RHB will be following up on this investigation."
California 5010 Number: 011921
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55073
Rep Org: NE DIV OF RADIOACTIVE MATERIALS
Licensee: Church of Jesus Christ of Latter Day Saints
Region: 4
City: Omaha State: NE
County:
License #: GL0450
Agreement: Y
Docket:
NRC Notified By: Deb Wilson
HQ OPS Officer: Donald Norwood
Licensee: Church of Jesus Christ of Latter Day Saints
Region: 4
City: Omaha State: NE
County:
License #: GL0450
Agreement: Y
Docket:
NRC Notified By: Deb Wilson
HQ OPS Officer: Donald Norwood
Notification Date: 01/19/2021
Notification Time: 16:37 [ET]
Event Date: 01/01/2007
Event Time: 00:00 [CST]
Last Update Date: 01/19/2021
Notification Time: 16:37 [ET]
Event Date: 01/01/2007
Event Time: 00:00 [CST]
Last Update Date: 01/19/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
GREG WARNICK (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
GREG WARNICK (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS
The following information was received via E-mail:
"The licensee's facility management group was going through their records and inventory. They discovered that six tritium exit signs at the Church in Blair, NE had been replaced with non-tritium signs in 2007. They are unable to find the documentation regarding the signs' disposal and therefore are unable to determine if they were disposed of properly. The building and storage buildings were searched and the signs were not found. Due to the lapse in time and purchase date of 10/25/1993, serial numbers were not available and no further follow-up will be conducted."
Nebraska Item Number: NE210002
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received via E-mail:
"The licensee's facility management group was going through their records and inventory. They discovered that six tritium exit signs at the Church in Blair, NE had been replaced with non-tritium signs in 2007. They are unable to find the documentation regarding the signs' disposal and therefore are unable to determine if they were disposed of properly. The building and storage buildings were searched and the signs were not found. Due to the lapse in time and purchase date of 10/25/1993, serial numbers were not available and no further follow-up will be conducted."
Nebraska Item Number: NE210002
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 55083
Facility: Watts Bar
Region: 2 State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Ryan B Nessell
HQ OPS Officer: Brian Lin
Region: 2 State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Ryan B Nessell
HQ OPS Officer: Brian Lin
Notification Date: 01/26/2021
Notification Time: 15:46 [ET]
Event Date: 01/26/2021
Event Time: 09:13 [EST]
Last Update Date: 01/26/2021
Notification Time: 15:46 [ET]
Event Date: 01/26/2021
Event Time: 09:13 [EST]
Last Update Date: 01/26/2021
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
MARK MILLER (R2DO)
FFD GROUP (EMAIL)
MARK MILLER (R2DO)
FFD GROUP (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 90 | Power Operation | 90 | Power Operation |
FITNESS FOR DUTY REPORT
A licensed operator had a confirmed positive alcohol test during a random fitness-for-duty test. The employee's access to the plant has been terminated.
The NRC Resident Inspectors have been notified.
A licensed operator had a confirmed positive alcohol test during a random fitness-for-duty test. The employee's access to the plant has been terminated.
The NRC Resident Inspectors have been notified.