Event Notification Report for May 5, 2016
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 05/04/2016 - 05/05/2016 ** EVENT NUMBERS ** | | Agreement State | Event Number: 51883 | Rep Org: TENNESSEE DIV OF RAD HEALTH Licensee: CLINICAL PHARMACY SERVICES, INC. Region: 1 City: GRAY State: TN County: License #: TN-16-059 Agreement: Y Docket: NRC Notified By: RUBEN CROSSLAND HQ OPS Officer: HOWIE CROUCH | Notification Date: 04/26/2016 Notification Time: 12:16 [ET] Event Date: 04/25/2016 Event Time: 03:45 [CDT] Last Update Date: 04/26/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): JAMES DWYER (R1DO) ANGELA MCINTOSH (NMSS) | Event Text AGREEMENT STATE REPORT - RELEASE OF LICENSED MATERIAL AND CONTAMINATION The following information was obtained from the State of Tennessee via email: "The Tennessee Division of Radiological Health received a call at 1350 CDT on 4/25/2016 from a consultant for Clinical Pharmacy Services in Gray, Tennessee. He stated that a vial containing 290 milliCuries of stabilized Iodine-131 had been dropped in the pharmacy onto the floor. The vial broke, splattering the liquid onto two pharmacists and objects in the room. Employees were stripped of their clothing. Thyroid count results are zero for both individuals. The Iodine-131 had been stabilized with a buffering agent making it non-volatile. Plastic sheeting and thick pieces of lead were placed over the contaminated areas. All personnel badges were overnighted to Landauer. The corporate compliance officers for Clinical Pharmacy were contacted and will arrive today. The consultant stated that the maximum dose rate at the point where the vial hit the floor was 66 mR/hr. through the lead sheeting. He stated a dose rate at 6 to 7 R/hr. Personnel were placing surface contaminated objects into a large leaded disposal bin." Tennessee Report No.: TN-16-059 | | Agreement State | Event Number: 51884 | Rep Org: GEORGIA RADIOACTIVE MATERIAL PGM Licensee: GEORGIA PACIFIC Region: 1 City: CEDAR SPRINGS State: GA County: License #: Agreement: Y Docket: NRC Notified By: YOSHIKA EASON HQ OPS Officer: BETHANY CECERE | Notification Date: 04/26/2016 Notification Time: 16:12 [ET] Event Date: 04/21/2016 Event Time: 00:00 [EDT] Last Update Date: 04/26/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): JAMES DWYER (R1DO) NMSS_EVENTS_NOTIFIC (EMAI) | Event Text AGREEMENT STATE REPORT - SHUTTER STUCK OPEN The following report was received from the State of Georgia via email: "On Tuesday, April 26, 2016 our department [Georgia Department of Natural Resources, Radioactive Materials Program] received a report from GA Pacific, Cedar Springs, Georgia, that the shutters were stuck in the open position on a Kay Ray fixed gauge with 2000 mCi of Cs-137 and a Berthold fixed gauge with 30 mCi of Cs-137. Georgia Pacific maintenance personnel were doing a 6 month service check and realized that the shutters would not close. The incident occurred on 4/21/16. On 4/22/16, [the licensee RSO] received the report and was trying to determine reporting requirements. On 4/25/16, [the RSO determined] that they needed to do a notification report but our office was closed. Our department was notified on 4/26/16. Tag devices are being used but work cannot be performed around the area near the tank/pipeline. Berthold has been contacted but Kay Ray is out of business. A complaint has been opened in CTS [Complaint Tracking System] and our office has an ongoing investigation." | | Non-Agreement State | Event Number: 51888 | Rep Org: SPECTRUM HEALTH Licensee: SPECTRUM HEALTH Region: 3 City: GRAND RAPIDS State: MI County: License #: 21-00243-06 Agreement: N Docket: NRC Notified By: EVAN BOOTE HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 04/27/2016 Notification Time: 17:09 [ET] Event Date: 04/27/2016 Event Time: 14:05 [EDT] Last Update Date: 04/27/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 35.3045(a)(2) - DOSE > SPECIFIED EFF LIMITS | Person (Organization): ANN MARIE STONE (R3DO) NMSS_EVENTS_NOTIFICA (EMAI) | Event Text MEDICAL EVENT - DOSE GIVEN TO INCORRECT SEGMENT OF THE LIVER During a Y-90 TheraSphere treatment (hepatocellular carcinoma) to the right lobe of the liver segments 5, 6, 7, and 8 (estimated volume of 1290 ml), the catheter moved and the dose was actually given to medial segment 4 (estimated volume of 330 ml). The prescribed dose was 120 Gy (3.3 GBq) and the delivered dose was approximately 118.5 Gy as determined by bremmstrahlung imaging. Segment 4 was previously treated and there was some residual cancer at this location. This dose is not expected to have detrimental effects on the patient. It is anticipated that segments 5,6,7,8 will be treated at some future time. The patient has been notified and the prescribing physician will be notified. A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | | Part 21 | Event Number: 51907 | Rep Org: ROTORK CONTROLS, INC. Licensee: JOHNSON ELECTRIC Region: 1 City: ROCHESTER State: NY County: License #: Agreement: Y Docket: NRC Notified By: PATRICK SHAW HQ OPS Officer: DONG HWA PARK | Notification Date: 05/04/2016 Notification Time: 14:56 [ET] Event Date: 01/25/2016 Event Time: [EDT] Last Update Date: 05/04/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 21.21(d)(3)(i) - DEFECTS AND NONCOMPLIANCE | Person (Organization): FRED BOWER (R1DO) MIKE ERNSTES (R2DO) NICK VALOS (R3DO) JOHN KRAMER (R4DO) PART 21/50.55 REACTO (EMAI) | Event Text PART 21 - ANOMALY RELATED TO MICRO SWITCHES The following report was received via email: "Based on test data, Rotork believes an unsafe condition may exist as defined under 10 CFR 21. The adhesive formulation used for the construction of V12 and K5 safety related micro switches was altered by the switch maker's sub-supplier. K5 switches have no reported failures, but are affected because of construction. The altered adhesive formulation outgases an insulating material at elevated temperatures, which coats the switch contacts as it cools and can prevent the conduction of electricity." | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021