Skip to main content

Event Notification Report for April 7, 2016

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
04/06/2016 - 04/07/2016

** EVENT NUMBERS **


51832 51833 51834 51835 51850 51851

To top of page
Agreement State Event Number: 51832
Rep Org: NEW YORK STATE DEPT. OF HEALTH
Licensee: UNSPECIFIED
Region: 1
City:  State: NY
County:
License #:
Agreement: Y
Docket:
NRC Notified By: J. KRISHNAMOORTHY
HQ OPS Officer: RICHARD SMITH
Notification Date: 03/30/2016
Notification Time: 15:35 [ET]
Event Date: 03/29/2016
Event Time: [EDT]
Last Update Date: 03/30/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JAMES DWYER (R1DO)
NMSS_EVENTS_NOTIFIC (EMAI)

Event Text

AGREEMENT STATE REPORT - MEDICAL EVENT

The following information was received from the State of New York via facsimile:

"The Licensee's Radiation Safety Officer called on March 29, 2016 to report that during the administration of Y90 to the liver of patient in the Interventional Radiology suite earlier in the day, only 3.9 mCi of the intended 11.7 mCi was administered due to a clogged catheter. [NY State Department of Health] will update after receiving report from the licensee."

NY State Incident No.:1136

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.

To top of page
Agreement State Event Number: 51833
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: ATC GROUP SERVICES, INC
Region: 1
City: TAMPA State: FL
County:
License #: 2962-2
Agreement: Y
Docket:
NRC Notified By: PAUL NORMAN
HQ OPS Officer: RICHARD SMITH
Notification Date: 03/30/2016
Notification Time: 16:05 [ET]
Event Date: 03/30/2016
Event Time: [EDT]
Last Update Date: 03/30/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JAMES DWYER (R1DO)
NMSS_EVENTS_NOTIFIC (EMAI)

Event Text

AGREEMENT STATE REPORT - DAMAGED MOISTURE/DENSITY GAUGE

The following information was received from the State of Florida via email:

"A Troxler Gauge was run over by heavy equipment at a construction site. The Type B container case was broken open exposing the source. [A Florida State] Inspector was sent to the scene to investigate."

State of Florida Incident Number: FL16-047

To top of page
Agreement State Event Number: 51834
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: TORRANCE UNIFIED SCHOOL DISTRICT
Region: 4
City: TORRANCE State: CA
County: LOS ANGELES
License #: N/A
Agreement: Y
Docket:
NRC Notified By: JEFF DAY
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/30/2016
Notification Time: 16:12 [ET]
Event Date: 03/29/2016
Event Time: [PDT]
Last Update Date: 03/30/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
VINCENT GADDY (R4DO)
NMSS_EVENTS_NOTIFIC (EMAI)
MEXICO (EMAI)

This material event contains a "Less than Cat 3 " level of radioactive material.

Event Text

AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS

The following information was received from the State of California via email:

"Torrance Unified School District (TUSD) reported to the RHB [Radiation Health Branch] via email on March 29. 2016 regarding nine tritium exit signs the school district is unable to account for after construction at two of their sites (5 signs at South High School located at 4801 Pacific Coast Highway, Torrance, CA 90505 and 4 signs at North High School located at 3620 W 182nd St, Torrance, CA 90504). TUSD has notified the contracted construction company, Balfour Beatty Construction, regarding the incident and requested removal documentation for the 9 exit signs, which to date has not been provided.

"The four Tritium Exit Signs from North High School located at 3620 W. 182nd St Torrance, CA 90504:
ISOLITE 2040-50G-20-BK Expiration date 1/1/23 received around 2/27/02 11.5 Curies Tritium
ISOLITE 2040-50G-20-BK Expiration date 1/1/23 received around 2/27/02 11.5 Curies Tritium
ISOLITE 2040-50G-20-BK Expiration date 1/1/23 received around 2/27/02 11.5 Curies Tritium
ISOLITE 2040-50G-20-BK Expiration date 1/1/23 received around 2/27/02 11.5 Curies Tritium

"The five Tritium Exit Signs from South High School located at 4801 Pacific Coast Hwy Torrance, CA 90505:
ISOLITE 2040-70G-20-BA Expiration date 4/20/22 Received around 1/15/02 11.5 Curies Tritium
ISOLITE 2040-70G-20-BA Expiration date 4/20/22 Received around 1/15/02 11.5 Curies Tritium
ISOLITE 2040-70G-20-BA Expiration date 4/01/22 Received around 1/15/02 11.5 Curies Tritium
ISOLITE SLX-60-S-G-20-B Expiration date 4/01/25 Received around 3/22/05 Est. 11.5 Curies Tritium
ISOLITE SLX-60-S-G-20-B Expiration date 4/01/25 Received around 3/22/05 Est. 11.5 Curies Tritium"

California 5010 Number: 032916 / TUSD

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

To top of page
Agreement State Event Number: 51835
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: KLEINFELDER, INC.
Region: 4
City: FRESNO State: CA
County:
License #: 6728-10
Agreement: Y
Docket:
NRC Notified By: NIKA HEWADIKARAM
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/30/2016
Notification Time: 17:18 [ET]
Event Date: 03/29/2016
Event Time: [PDT]
Last Update Date: 03/30/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
VINCENT GADDY (R4DO)
NMSS_EVENTS_NOTIFIC (EMAI)

Event Text

AGREEMENT STATE REPORT - DAMAGED MOISTURE/DENSITY GAUGE

The following information was received from the State of California via email:

"On 03/29/16, the California Office of Emergency Services (OES) contacted the RHB [Radiation Health Branch] via an email to notify them of a damaged moisture/density gauge. The gauge was a Troxler gauge, Model 3440, S/N 38618 containing 9 mCi of Cs-137 and 44 mCi of Am-241. The gauge had been run over by an excavator while the operator was taking a reading along the side of the road where the incident occurred. Per the licensee, the Cs-137 source was in the shielded position (at the time of the incident readings were taken over a standard block for counts) when the gauge was damaged. The licensee stated that a 20 foot area was cordoned off until the gauge was removed. Fire Department personnel were at the scene.

"Per the licensee, a Pacific Nuclear Technology (PNT) RSO arrived at the site, and confirmed a survey meter reading of 0.5 mRems at one meter from the gauge, which is considered normal for this type of gauge. It was also noted that the Cs-137 and Am-241 sources were intact. Survey of the area after removal of the gauge indicated background readings. The gauge was placed inside the transit cage and returned to the licensee's storage location. A leak test will be performed and the gauge will be disposed of in the near future. RHB will be following up on this incident."

California 5010 Number: 032916 / Kleinfelder

To top of page
Power Reactor Event Number: 51850
Facility: BROWNS FERRY
Region: 2 State: AL
Unit: [ ] [ ] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: MATTHEW SLOUKA
HQ OPS Officer: JEFF HERRERA
Notification Date: 04/06/2016
Notification Time: 17:07 [ET]
Event Date: 04/06/2016
Event Time: 15:45 [CDT]
Last Update Date: 04/07/2016
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
REBECCA NEASE (R2DO)
BERNARD STAPLETON (IRD)
BILL DEAN (NRR)
CATHY HANEY (R2RA)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 91 Power Operation

Event Text

UNUSUAL EVENT DECLARED DUE TO MAIN STEAMLINE HIGH HIGH RADIATION CONDITION

At 1545 CDT on 04/06/16 Browns Ferry Unit 3 declared and exited the declaration of an unusual event due to a main steam line high high radiation condition. Power to Unit 3 was reduced to 91 percent power. The high radiation condition alarm cleared at 1526 CDT. Browns Ferry Unit 3 reported that the high radiation conditions were due to resin intrusion from the condensate demineralizers into the reactor and hydrogen water chemistry was a potential contributor to the event. The cause is still under investigation.

The NRC Resident Inspector has been notified.

State and Local notifications were made.

Notified DHS SWO, FEMA Ops Center, NICC Watch Officer, FEMA NWC and Nuclear SSA (email).

* * * UPDATE FROM BILL BALL TO DANIEL MILLS AT 0034 EDT ON 04/07/2016 * * *

"At 1941 [CDT] BFN [Brown's Ferry] determined this notification to be potentially newsworthy due to receiving notification that counties [surrounding the plant] were alerted of this event. No plant conditions changed."

The licensee may issue a press release.

The licensee will notify the NRC Resident Inspector.

Notified R2DO (Nease).

To top of page
Power Reactor Event Number: 51851
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [1] [2] [ ]
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: LONNIE CRAWFORD
HQ OPS Officer: STEVEN VITTO
Notification Date: 04/06/2016
Notification Time: 17:27 [ET]
Event Date: 04/06/2016
Event Time: 13:37 [EDT]
Last Update Date: 04/06/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
DON JACKSON (R1DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
2 N Y 100 Power Operation 100 Power Operation

Event Text

REACTOR BUILDING AIRLOCK DOORS OPENED SIMULTANEOUSLY

"On April 6th, 2016 at 1337 [EDT] and 1343 [EDT] Secondary Containment became inoperable due to failure to meet a Surveillance Requirement (SR 3.6.4.1.3) on Unit 1 and Unit 2.

"The inoperability was caused when two separate sets of Reactor Building airlock doors were sequentially opened during a medical emergency to transport an individual. Each set of airlock doors was opened momentarily to allow passage.

"Secondary Containment was restored April 6, 2016 at 1344 [EDT] when the transport evolution was complete.

"This event is being reported under 10 CFR 50.72(b)(3)(v)(c) and per the guidance of NUREG 1022 Rev 3 section 3.2.7 as a loss of a Safety Function. There is no redundant Susquehanna Secondary Containment system."

The NRC Resident Inspector has been notified.

Page Last Reviewed/Updated Wednesday, March 24, 2021