Event Notification Report for August 1, 2013
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 07/31/2013 - 08/01/2013 ** EVENT NUMBERS ** | | Agreement State | Event Number: 49212 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: FOX NDE LLC Region: 4 City: ABILENE State: TX County: License #: 06411 Agreement: Y Docket: NRC Notified By: ART TUCKER HQ OPS Officer: DONG HWA PARK | Notification Date: 07/24/2013 Notification Time: 10:16 [ET] Event Date: 07/20/2013 Event Time: [CDT] Last Update Date: 07/24/2013 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): DON ALLEN (R4DO) FSME EVENTS RESOURCE (EMAI) | Event Text AGREEMENT STATE REPORT - UNABLE TO RETRACT SOURCE INTO RADIOGRAPHY CAMERA The following information was obtained from the State of Texas via E-mail: "On July 23, 2013, the Agency [Texas Department of State Health Services] was notified by the licensee that on July 20, 2013, a radiography crew was unable to retract an Iridium - 192 source into a QSDA 880 D exposure device. The failure was caused by a spool that had fallen on the guide tube, crimping the tube so that the source could not pass through the tube at the crimp. The radiographers isolated the area, placed bags of concrete over the source to reduce area dose rates, and contacted their Radiation Safety Officer (RSO). The RSO drove to the location and reach the site about six hour later. The RSO was able to remove the crimp enough to allow the source to pass through the crimp and lock back in the exposure device. The camera was returned to the licensee's facility for further inspection. No one involved in the event received an exposure that exceeded any regulatory limit. No member of the general public was exposed to any radiation due to this event. Additional information will be provided as it is received in accordance with SA-300." Texas Incident #: I-9099 | | Power Reactor | Event Number: 49228 | Facility: HARRIS Region: 2 State: NC Unit: [1] [ ] [ ] RX Type: [1] W-3-LP NRC Notified By: RICHARD DAVIS HQ OPS Officer: NESTOR MAKRIS | Notification Date: 07/31/2013 Notification Time: 11:40 [ET] Event Date: 07/31/2013 Event Time: 05:10 [EDT] Last Update Date: 07/31/2013 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): MICHAEL F. KING (R2DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text EMERGENCY RESPONSE FACILITY PREPLANNED MAINTENANCE "This condition does not affect the health and safety of the public or the operation of the facility. At 0510 [EDT] on July 31, 2013, preplanned maintenance commenced which affects the Technical Support Center (TSC) ventilation and radiation monitoring systems. The scope of the maintenance is to inspect and perform functional checks on various TSC ventilation system fans and the outside air intake radiation monitor. This maintenance is scheduled to be performed and completed within approximately 20 hours. "TSC functionality requires all occupied areas of the TSC be maintained between 60.8 degrees F and 82.4 degrees F. Actual TSC temperatures have been verified to be less than 78 degrees F. If an emergency should occur, the ventilation system will be restored, but potentially not within the time required for activation of the TSC. If the facility were activated with full staff, temperatures could rise above the 82.4 degree F limit. Consideration will be given to relocating the TSC to the alternate emergency facility in accordance with PEP-240. The alternate TSC has been verified to have electrical power, ventilation, and communication capability. The Technical Support Center - Site Emergency Coordinator has been notified. "The NRC Resident Inspector has been notified." * * * UPDATE AT 1620 EDT ON 07/31/13 FROM RICHARD DAVIS TO S. SANDIN * * * Preplanned maintenance was completed at 1540 EDT on 7/31/13. The licensee informed the NRC Resident Inspector. Notified R2DO (King). | | Part 21 | Event Number: 49230 | Rep Org: ABB INC. Licensee: ABB INC. Region: 1 City: FLORENCE State: SC County: License #: Agreement: Y Docket: NRC Notified By: JAY LAVRINC HQ OPS Officer: DONALD NORWOOD | Notification Date: 07/31/2013 Notification Time: 17:45 [ET] Event Date: 07/31/2013 Event Time: [EDT] Last Update Date: 07/31/2013 | Emergency Class: NON EMERGENCY 10 CFR Section: 21.21(d)(3)(i) - DEFECTS AND NONCOMPLIANCE | Person (Organization): GORDON HUNEGS (R1DO) MICHAEL F. KING (R2DO) STEVE ORTH (R3DO) THOMAS FARNHOLTZ (R4DO) PART 21 REACTORS (EMAI) | Event Text PART 21 REPORT - DEVIATION OF HK CIRCUIT BREAKER CLOSE LATCH SPRING ABB identified a deviation with close latch springs provided since 1/20/2010 used in medium voltage HK circuit breakers. These close latch springs are used on new legacy HK circuit breakers, replaced during HK circuit breaker refurbishment activities, and provided in HK refurbishment kits and as component items. The ABB part number for the close latch spring is: 162374A00. The nature of the deviation is a reduced spring force. There is a potential for an aged HK circuit breaker with hardening grease and this reduced spring force not to close. The following is a list of affected customers: Detroit Edison Fermi 2 Dominion VA DTE Duke Catawba Duke Energy - Seneca Duke Energy - Cataw Duke Huntersville Duke McGuire Duke Oconee Entergy River Bend Exelon Limerick Exelon Nuclear Exelon Peach Bottom Exelon Point Beach First Energy Beaver Valley Georgia Power Plant Vogtle Nextera Point Beach Nextera Seabrook Prairie Island Nuclear Progress Energy Brunswick Progress Energy Crystal River PSEG Alloway Creek Southern Cal Edison STP Nuclear TVA Sequoyah. | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021