Event Notification Report for November 3, 2011
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 11/02/2011 - 11/03/2011 ** EVENT NUMBERS ** | | Hospital | Event Number: 47384 | Rep Org: JEPPESEN RADIATION ONCOLOGY Licensee: BAY REGIONAL MEDICAL CENTER Region: 3 City: BAY CITY State: MI County: License #: 21-18585-01 Agreement: N Docket: NRC Notified By: DENNIS KEHOE HQ OPS Officer: JOE O'HARA | Notification Date: 10/28/2011 Notification Time: 15:26 [ET] Event Date: 01/11/2011 Event Time: 07:00 [EDT] Last Update Date: 11/01/2011 | Emergency Class: NON EMERGENCY 10 CFR Section: 35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE | Person (Organization): PATTY PELKE (R3DO) LYDIA CHANG (FSME) | Event Text MEDICAL EVENT - MISADMINISTRATION OF PROSTATE CANCER SEEDS During a recent inspection, an NRC inspector noted two cases which occurred on 8/23/11 and 1/11/11, respectively in which two separate patients were under dosed by greater than 20% during prostate cancer treatment using Iodine 125 seeds. The underdose was determined during post operative treatments. The same physician administered the procedure in both cases. The licensee has informed the prescribing physician, and is investigating the cause of the events. There is no long term permanent functional damage suspected to any organ in either case. The licensee discussed the issue with NRC Region 3 (Gattone). * * * UPDATE FROM DENNIS KEHOE TO VINCE KLCO ON 11/01/11 AT 1841 EDT * * * After the licensee reviewed 3 years of medical reports, fourteen patents were found to have been under-dosed greater than 20% of the prescribed dose. Specific under-dose dates were: 4/10/08; 4/21/08; 4/25/08; 9/15/08; 10/17/08; 11/03/08; 2/17/09; 8/27/09; 1/05/10; 1/14/10; 5/25/10; 10/12/10; 5/03/11 and 5/19/11. The licensee discussed the issue with NRC Region 3 (Gattone). Notified the R3DO (Valos) and the FSME EO (Camper). A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | | Agreement State | Event Number: 47385 | Rep Org: PA BUREAU OF RADIATION PROTECTION Licensee: LANKENAU HOSPITAL Region: 1 City: WYNNEWOOD State: PA County: License #: PA-0107 Agreement: Y Docket: NRC Notified By: JOE MELNIC HQ OPS Officer: JOHN KNOKE | Notification Date: 10/28/2011 Notification Time: 16:02 [ET] Event Date: 10/06/2011 Event Time: 00:00 [EDT] Last Update Date: 10/28/2011 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): ANNE DeFRANCISCO (R1DO) LYDIA CHANG (FSME) | Event Text AGREEMENT STATE REPORT - FETUS EXPOSED TO RADIATION DURING THYROID THERAPY TREATMENT The following was received from the state via facsimile: "The patient took a pregnancy test on October 5, 2011 and the results were negative. The patient was then treated with 73.7mCi of I-131 thyroid therapy treatment on October 6, 2011. The patient discovered she was pregnant and contacted the licensee on October 26, 2011. The estimated dose to the fetus is 17.4 Rads. It has been determined that the fetus was 10 days old when the therapy was given to the patient. "The licensee will be submitting a written report within 15 days. The Department plans to do a reactive inspection to review licensee's procedures and response to this ME." Event Report ID No. PA110031 | | Power Reactor | Event Number: 47403 | Facility: BEAVER VALLEY Region: 1 State: PA Unit: [1] [ ] [ ] RX Type: [1] W-3-LP,[2] W-3-LP NRC Notified By: DAVID GIBSON HQ OPS Officer: VINCE KLCO | Notification Date: 11/02/2011 Notification Time: 20:41 [ET] Event Date: 11/02/2011 Event Time: 14:30 [EDT] Last Update Date: 11/02/2011 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(ii)(B) - UNANALYZED CONDITION | Person (Organization): NEIL PERRY (R1DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text UNANALYZED CONDITION CAUSED BY NON-CONFORMING FIRE BARRIERS "Ongoing field inspections as a result of Industry Operating Experience have identified certain fire barriers that are not in conformance with required tested configurations. Specifically, some of the flexible conduit that penetrates these barriers has a coating that does not exhibit flame retardant characteristics and therefore does not meet the requirements for fire barriers at Beaver Valley Power Station, Unit 1. "In the event of a postulated fire, this non-conformance has the potential to affect fire barriers separating the two independent trains required for post fire Safe Shutdown equipment. This issue is being reported per 10CFR 50.72(b)(3)(ii)(B). "Compensatory actions have been established in accordance with the approved Fire Protection Program. "The NRC Resident Inspector has been notified." | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021