Event Notification Report for May 19, 2011
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 05/18/2011 - 05/19/2011 ** EVENT NUMBERS ** | | Agreement State | Event Number: 46848 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: SOLO CUP OPERATING CORPORATION Region: 4 City: DALLAS State: TX County: License #: 02174 Agreement: Y Docket: NRC Notified By: ART TUCKER HQ OPS Officer: JOHN KNOKE | Notification Date: 05/13/2011 Notification Time: 07:50 [ET] Event Date: 05/12/2011 Event Time: [CDT] Last Update Date: 05/13/2011 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): WAYNE WALKER (R4DO) ANGELA MCINTOSH (FSME) | Event Text AGREEMENT STATE REPORT - STUCK SHUTTER ON NUCLEAR GAUGE The following information from the State was received by email: "On May 12, 2011, the Agency [Texas Department of Health] was notified by the licensee that the shutter on a Ohmart/Vega Model BAL nuclear gauge containing 100 milliCuries of Strontium (Sr) - 90 was stuck in the closed position. The gauge has an electronic shutter, which is not functioning. The licensee contacted their service provider for assistance in repairing the gauge. The cause for the failure is being investigated. Additional information will be provided as it is received in accordance with SA-300." Texas Incident No: I-8847 | | Agreement State | Event Number: 46849 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: SOLO CUP OPERATING CORPORATION Region: 4 City: DALLAS State: TX County: License #: 02174 Agreement: Y Docket: NRC Notified By: ART TUCKER HQ OPS Officer: JOHN KNOKE | Notification Date: 05/13/2011 Notification Time: 07:59 [ET] Event Date: 04/18/2011 Event Time: [CDT] Last Update Date: 05/13/2011 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): WAYNE WALKER (R4DO) ANGELA MCINTOSH (FSME) | Event Text AGREEMENT STATE REPORT - MISSING SHUTTER ON NUCLEAR GAUGE The following information from the State was received by email: "On May 12, 2011, the Agency [Texas Department of Health] was notified by the licensee that on April 18, 2011, while conducting a routine inspection of a NDC model 8000 TDI nuclear gauge containing 80 milliCuries of Americium (Am) - 241 they found the shutter for the device was missing. The licensee conducted a search for the shutter, but it was not found. The licensee contacted the manufacturer for assistance in repairing the gauge. The licensee placed a lead plate over the shutter to prevent exposure to personnel. The gauge was repaired by the manufacturer on April 29, 2011. Additional information will be provided as it is received in accordance with SA-300." Texas Incident No: I-8848 | | Agreement State | Event Number: 46850 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: UNION CARBIDE CORPORATION Region: 4 City: PORT LAVACA State: TX County: License #: 00051 Agreement: Y Docket: NRC Notified By: ART TUCKER HQ OPS Officer: JOHN KNOKE | Notification Date: 05/13/2011 Notification Time: 08:00 [ET] Event Date: 05/11/2011 Event Time: [CDT] Last Update Date: 05/18/2011 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): WAYNE WALKER (R4DO) ANGELA MCINTOSH (FSME) | Event Text AGREEMENT STATE REPORT - SHUTTER STUCK OPEN ON NUCLEAR GAUGE The following information from the State was received by email: "On May 12, 2011, the Agency [Texas Department of Health] was notified by the licensee that while performing a routine inspection of a Ohmart/Vega model SH-F2 nuclear gauge containing 200 milliCuries of Cesium (Cs) - 137 they found the shutter for the device stuck in the open position. The licensee believes the probable cause for the event is a buildup of debris in the operating mechanism of the gauge. The gauge is used for level detection on a vent stack in an area of the plant not routinely occupied. The licensee is lubricating and trying to cycle the shutter frequently. The licensee has contacted a service provider to assist them if needed. No exposure to any personnel has occurred due to this event. Additional information will be provided as it is received in accordance with SA-300." Texas Incident No: I-8849 * * * UPDATE FROM ART TUCKER TO CHARLES TEAL VIA EMAIL ON 5/18/11 @ 0915 EDT * * * "On May 16, 2011, the licensee reported that the repeated lubrication of the shutter was successful and that the shutter was now working as designed. The report also stated that the event was discovered on May 11, 2011, not May 12, 2011, as first reported." Notified R4DO (Shannon) and FSME (McIntosh). | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021