Power Reactor
Event Number: 45235
Facility: CALVERT CLIFFS
Region: 1     State: MD
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: KEVIN UMPHREY
HQ OPS Officer: DONG HWA PARK
Notification Date: 07/29/2009
Notification Time: 12:40 [ET]
Event Date: 07/28/2009
Event Time: 17:00 [EDT]
Last Update Date: 07/29/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY REPORT - POSSIBLE LOSS OF TEST RESULTS

The licensee submitted test specimens to a certified laboratory for analysis. After 5 business days, the results of the test were not reported back to the licensee. The individuals affected are being retested. Contact the Headquarters Operations Officer for additional details.


Power Reactor
Event Number: 48723
Facility: WATTS BAR
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BRIAN McINLNAY
HQ OPS Officer: BILL HUFFMAN
Notification Date: 02/06/2013
Notification Time: 16:00 [ET]
Event Date: 07/28/2009
Event Time: 00:00 [EST]
Last Update Date: 02/06/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
GEORGE HOPPER (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
UNANALYZED CONDITION THAT COULD HAVE RESULTED IN AN INCREASED MAXIMUM FLOOD LEVEL

"On July 28, 2009, TVA identified, in the Corrective Action Program, the potential to overtop and fail earthen embankments at Cherokee, Fort Loudoun, Tellico, and Watts Bar Dams. This condition could have resulted in an increase in the probable maximum flood (PMF) level at Watts Bar Unit 1. TVA initiated immediate actions to address the condition by conducting additional analyses and the development of contingent actions. Additional actions were developed including the installation of modular flood barriers [which were] completed in December 2009. The barriers increase the effective height of the affected embankments preventing their overtopping and failure. The increase in PMF could have affected plant equipment including the emergency diesel generator system, the essential raw cooling water system, the thermal barrier booster pumps and the control room chillers.

"Additional details regarding the modular flood barriers and the results of TVA's subsequent hydrologic analyses for Watts Bar were discussed in public meetings between TVA and the NRC staff on July 7, 2010 and May 31, 2012, and provided in TVA letters to the NRC dated July 19, 2012, October 30, 2012 and January 18, 2013.

"This report addresses a condition as described in 10 CFR 50.72(b)(3)(ii)(B). Affected safety related equipment is currently operable.

"The NRC Resident Inspector has been notified of this condition."

See related event notifications from Browns Ferry (EN #48724) and Sequoyah (EN #48725).


Power Reactor
Event Number: 48724
Facility: BROWNS FERRY
Region: 2     State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: RODNEY NACOSTE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 02/06/2013
Notification Time: 16:31 [ET]
Event Date: 07/28/2009
Event Time: 00:00 [CST]
Last Update Date: 02/06/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
GEORGE HOPPER (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
UNANALYZED CONDITION THAT COULD HAVE RESULTED IN AN INCREASED MAXIMUM FLOOD LEVEL

"On July 28, 2009, TVA identified, in the Corrective Action Program, the potential to overtop and fail earthen embankments at Cherokee, Fort Loudoun, Tellico, and Watts Bar Dams. Prior Browns Ferry Nuclear (BFN) analysis did not consider the potential to overtop and fail the earthen embankments at Cherokee Dam. This condition could have resulted in an increase in the probable maximum flood (PMF) level at Browns Ferry Nuclear Plant Units 1, 2 and 3. TVA initiated immediate actions to address the condition by conducting additional analyses and developing contingent actions. Additional actions were developed including the installation of modular flood barriers [which were] completed in December 2009. The barriers increase the effective height of the affected embankments preventing their overtopping and failure.

"Additional details regarding the modular flood barriers and the results of TVA's subsequent hydrologic analyses were discussed in a public meeting between TVA and the NRC staff on July 7, 2010.

"This report addresses a condition as described in 10 CFR 50.72(b)(3)(ii)(B). Subsequent analyses, completed in November 2012, determined that there are no past operability concerns with this condition at BFN.

"The NRC Resident inspector has been notified of this condition."

See related event notifications from Watts Bar (EN #48723) and Sequoyah (EN #48725).


Power Reactor
Event Number: 48725
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: HAROLD HOWLE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 02/06/2013
Notification Time: 17:10 [ET]
Event Date: 07/28/2009
Event Time: 00:00 [EST]
Last Update Date: 02/06/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
GEORGE HOPPER (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
UNANALYZED CONDITION THAT COULD HAVE RESULTED IN AN INCREASED MAXIMUM FLOOD LEVEL

"On July 28, 2009, TVA identified, in the Corrective Action Program, the potential to overtop and fail earthen embankments at Cherokee, Fort Loudoun, Tellico, and Watts Bar Dams. This condition could have resulted in an increase in the probable maximum flood (PMF) level at Sequoyah Nuclear (SQN) Units 1 & 2. TVA initiated immediate actions to address the condition by conducting additional analyses and developing contingent actions. Additional actions were developed including the installation of modular flood barriers [which were] completed in December 2009. The barriers increase the effective height of the affected embankments preventing their overtopping and failure. The increase in PMF could have affected plant equipment including the emergency diesel generator system and the essential raw cooling water system.

"Additional details regarding the modular flood barriers and the results of TVA's subsequent hydrologic analyses for SQN were discussed in public meetings between TVA and the NRC staff on July 7, 2010 and May 31, 2012, and provided in TVA letters to the NRC dated August 10, 2012, October 30, 2012, and January 18, 2013.

"This report addresses a condition as described in 10 CFR 50.72 (b)(3)(ii)(B). Affected safety-related equipment is currently operable.

"The NRC Resident Inspector has been notified of this condition."

See related event notifications from Watts Bar (EN #48723) and Browns Ferry (EN #48724).


General Information or Other
Event Number: 45292
Rep Org: LOUISIANA DEQ
Licensee: CAMERON VALVE AND MEASUREMENTS
Region: 4
City: VILLE PLATTE   State: LA
County:
License #: LA-7095-L01
Agreement: Y
Docket:
NRC Notified By: ANN TROXLER
HQ OPS Officer: CHARLES TEAL
Notification Date: 08/25/2009
Notification Time: 10:56 [ET]
Event Date: 07/28/2009
Event Time: 00:00 [CDT]
Last Update Date: 08/25/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
GEOFFREY MILLER (R4DO)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE REPORT - SOURCE DISCONNECT OF RADIOGRAPHY CAMERA

The following is a summary of a fax received from the state of Louisiana:

At approximately 10:30 p.m. on the night of July 28, 2009, a radiographer failed to connect the source tube to the camera before he cranked out the source. The cable stop that is attached to the worm cable did not work properly. After dismantling the crankout assembly, the source was hand retrieved and placed back into the camera using the worm cable. A survey was taken to verify that the source was stored safely. The total time of retrieval was approximately 2 minutes.

No personnel were overexposed during this event.

Louisiana Report #: LA090016