Skip to main content

Event Notification Report for October 17, 2007

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
10/16/2007 - 10/17/2007

** EVENT NUMBERS **


43725

To top of page
Other Nuclear Material Event Number: 43725
Rep Org: CTI & ASSOC. INC.
Licensee: CTI & ASSOC. INC.
Region: 3
City: BRIGHTON State: MI
County:
License #: 21-17007-01
Agreement: N
Docket:
NRC Notified By: JIM MEEHLE
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/16/2007
Notification Time: 16:05 [ET]
Event Date: 10/16/2007
Event Time: 11:00 [EDT]
Last Update Date: 10/16/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
KENNETH RIEMER (R3)
GREG MORELL (FSME)

Event Text

DAMAGED TROXLER MOISTURE DENSITY GAUGE


10/16/07 at 1100 EDT a Troxler 3401; 8 millicuries Cs-137 and 40 millicuries Am-241/Be, was run over by a bulldozer while the gauge operator was driving the drive rod into the ground (was going to test the compaction of the soil). The gauge operator was about 15 to 20 feet away from the gauge when it was run over. The top handle and the top of the source rod were sheared off. The Radiation Safety Officer came to the site and took surveys. Surveys found no contamination and the gauge is presently in its locked position on the tail of a truck. The survey readings of the gauge from 2 feet away ranged from 0.06 to 0.1 millirems per hour (survey readings were taken using a TroxAlert meter). The RSO will have the gauge leaked tested and then he plans to ship the gauge back to Troxler for repairs/disposal. Serial number of the gauge is 5323.

This incident occurred at 6825 West Jefferson Ave., Detroit, MI at a basement excavation site.

NRC Region 3, Darrel Wiedeman, was notified of this incident by Jim Meehle.

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021