| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 08/03/2006 - 08/04/2006 ** EVENT NUMBERS ** | | Power Reactor | Event Number: 42652 | Facility: MONTICELLO Region: 3 State: MN Unit: [1] [ ] [ ] RX Type: [1] GE-3 NRC Notified By: RYAN RICHARDS HQ OPS Officer: JOHN MacKINNON | Notification Date: 06/19/2006 Notification Time: 04:06 [ET] Event Date: 06/18/2006 Event Time: 23:19 [CDT] Last Update Date: 08/03/2006 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION | Person (Organization): PATRICK LOUDEN (R3) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text RADIATION MONITOR SPIKED THREE TIMES "At 2319 on 06/18/2006, the 'A' Plenum Radiation Monitor spiked high which resulted in the closure of the Drywell CAM (Continuous Air Monitor) and the Oxygen Analyzer Primary Containment Isolation Valves. The spike's (3) of approx. 30 Mr/HR occurred during this event. The valves isolated once, the Reactor Building Ventilation trip was reset once and re-isolation occurred several minutes later from another spike on the Rad Monitor. Trip setpoint is 26 Mr/hr. The Plenum high Rad signal also resulted in Reactor Building isolation (twice), start of 'A' Standby Gas Treatment, and transfer of the Control Room Ventilation to the high Rad Mode. The 'B' Plenum Rad Monitor remained constant at 1.3 Mr/hr. The Reactor Building Ventilation and Control Room Ventilation have been reset and Standby Gas Treatment has been secured. The 'A' Plenum Radiation Monitor has been declared inoperable." Instrument & Control Technicians are currently troubleshooting the problem associated with the 'A' Plenum Radiation Monitor. The NRC Resident Inspector's have been left messages by the licensee. * * * UPDATE AT 10:15 ON 8/3/2006 FROM ROBERT SCHREIFELS TO ABRAMOVITZ * * * This report is being reclassified by the licensee from a 50.72(b)(3)(iv)(A) [valid system actuation] to 50.73(a)(2)(iv)(A) [invalid system actuation]. "Based on further investigation, Monticello has determined that the actuation signal was due to a failed microswitch and therefore was not a valid signal. Because the actuation signal was not valid, Monticello is retracting the initial event report and instead reporting this event as an unplanned system actuation under 50.73(a)(2)(iv)(A). This report will be made in lieu of reporting the event as an LER. "In accordance with 50.73(a)(2)(iv)(A): "This report is not considered an LER and the report is being made under 50.73(a)(2)(iv)(A). The original event report (ENS #42652) detailed the systems affected, whether the actuation was complete or partial and whether each affected system started and functioned successfully. "The cause of the invalid signal was the failure of the trip check pushbutton [micro]switch due to age related degradation. The switch has been replaced and the 'A' Plenum Radiation Monitor was returned to service." The licensee notified the NRC Resident Inspector. Notified the R3DO (O'Brien). | | General Information or Other | Event Number: 42741 | Rep Org: MA RADIATION CONTROL PROGRAM Licensee: BRUKER DALTONICS NBC DETECTION CORP Region: 1 City: BILLERICA State: MA County: License #: 38-0257 Agreement: Y Docket: NRC Notified By: TONY CARPENITO HQ OPS Officer: JOHN KNOKE | Notification Date: 07/31/2006 Notification Time: 08:56 [ET] Event Date: 06/14/2006 Event Time: [EDT] Last Update Date: 08/03/2006 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): PAT FINNEY (R1) GREG MORELL (NMSS) ILTAB EMAIL () CANADA EMAIL () | | This material event contains a "Less than Cat 3" level of radioactive material. | Event Text AGREEMENT STATE REPORT - MISSING SHIPMENT OF NI-63 The State provided the following information via facsimile: "On 7/13/06, licensee reported [ to State of MA] that a Raid-M-100 Hand-Held Chemical Agent Monitor (S/N 22653301851) containing up to 100 Mbq (2.7 mCi) of Nickel-63, shipped by licensee employee on 6/5/06 from Anchorage, AK, via United Parcel Service was reported as being not yet received at the licensee's Billerica, MA, site on 6/14/05. A second package, containing work related non-radioactive items, that had been shipped at the same time was received on 6/8/06. The device was in the custody of UPS at the time of the loss. UPS tracking system indicates the package was scanned in AK. Per the licensee, UPS reported on 6/19/06 and on 6/29/06 that its internal investigation had not yet found the missing item. Licensee filed incident report with Anchorage Police Department. The UPS missing package investigation is ongoing." The site of the event and last known location was UPS, 200 West 34th Avenue, Anchorage, AK. MA Report 7/31/06, Docket # 07-6484 * * * UPDATE ON 8/3/06 AT 1000 EST BY J KOZAL * * * Informed the Canadian government of above event via e-mail. THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source | | General Information or Other | Event Number: 42742 | Rep Org: OHIO BUREAU OF RADIATION PROTECTION Licensee: H. C. NUTTING COMPANY Region: 3 City: CINCINNATI State: OH County: License #: 31210310024 Agreement: Y Docket: NRC Notified By: MICHAEL SNEE HQ OPS Officer: ARLON COSTA | Notification Date: 07/31/2006 Notification Time: 12:51 [ET] Event Date: 07/30/2006 Event Time: [EDT] Last Update Date: 07/31/2006 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): KENNETH O'BRIEN (R3) GREG MORELL (NMSS) ILTAB EMAIL () | | This material event contains a "Less than Cat 3" level of radioactive material. | Event Text OHIO AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE The State provided the following information via email: "The Bureau was informed by the RSO of the H.C. Nutting Company (Ohio license # 31210310024) on July 31, 2006 that a moisture density gauge (Troxler model 3430, serial # 23699) was stolen from the back of a truck parked in a closed garage at a residence in Columbus, Ohio. A lock and chain were cut to gain access to the gauge. The theft occurred between 2:30 PM and 8:30 PM on July 30, 2006. A report was filed with the Columbus Police Department. The [Ohio] Bureau is investigating." The gauge contains two sealed sources: Cs-137 (9 millicuries) and Am-241:Be (44 millicuries). OH Incident Number: OH2006-061. THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. | | Power Reactor | Event Number: 42751 | Facility: GINNA Region: 1 State: NY Unit: [1] [ ] [ ] RX Type: [1] W-2-LP NRC Notified By: DOUG GOMEZ HQ OPS Officer: BILL GOTT | Notification Date: 08/02/2006 Notification Time: 18:41 [ET] Event Date: 08/02/2006 Event Time: 11:27 [EDT] Last Update Date: 08/03/2006 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(A) - POT UNABLE TO SAFE SD | Person (Organization): PAT FINNEY (R1) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text POST CONTINGENCY LOW VOLTAGE ALARM "The Rochester Gas and Electric (RG&E) Energy Control Center (ECC) notified Ginna Operations that the Post Contingency Low Voltage Alarm was received for the off site power system. Ginna Operations entered procedure O-6.9, operating Limits for Ginna Station Transmission, and declared the offsite power inoperable per ITS 3.8.1[72 hour LCO]. Per NUREG-1022, section 3.2.7, if either offsite power or onsite emergency power is unavailable to the plant, it is reportable per 50.72(b)(3)(v)(A) regardless of whether the other system is available. "The RG&E Energy Control Center (ECC) monitors 115 kV voltage using their State Estimation and Contingency Analysis System. The State Estimation portion of the system evaluates real time system power flow and voltages on the 115 and 345 kV transmission systems. The Contingency Analysis portion analyzes the voltage effect of a Ginna main generator trip concurrent with worst case accident loading. If the Station 13A voltage would drop below the minimum required voltage for offsite power alignment a Ginna Post Contingency Low Voltage Alarm occurs. "If the main generator should trip, then the absence of a Post Contingency Low Voltage Alarm on the RG&E State Estimation and Contingency Analysis System will ensure that the subsequent offsite 115kV system voltage transient will not result in Ginna Station experiencing an under voltage condition on the 480V Safeguard Busses. "The RG&E ECC notified Ginna operations that the Post Contingency Low Voltage Alarm cleared at 1408 EDST on 08/02/2006 and the LCO for ITS 3.8.1 was exited at 1704 after observation of grid stability. The plant was maintained at 100% steady state conditions throughout the event." The licensee notified the NRC Resident Inspector. * * * UPDATE FROM KYLE GARNISH TO W. GOTT AT 1430 ON 08/03/06 * * * "This is an additional notification for EN #42751 that was reported on 8/2/06 for offsite power being declared inoperable. A subsequent investigation revealed that offsite power was also inoperable on 7/17/2006 from 1427 to 1448 and on 8/1/2006 from 1022 to 1843 for which a notification was not completed." The licensee notified the NRC Resident Inspector. Notified R1DO P. Finney | |