Event Notification Report for January 24, 2005
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 01/21/2005 - 01/24/2005 ** EVENT NUMBERS ** | | General Information or Other | Event Number: 41343 | Rep Org: NC DIV OF RADIATION PROTECTION Licensee: BUILDING & EARTH SCIENCES, INC. Region: 1 City: COLUMBUS State: GA County: License #: Agreement: Y Docket: NRC Notified By: LEE COX HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 01/18/2005 Notification Time: 16:50 [ET] Event Date: 01/17/2005 Event Time: 07:25 [EST] Last Update Date: 01/18/2005 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): HAROLD GRAY (R1) E. WILLIAM BRACH (NMSS) | Event Text NORTH CAROLINA AGREEMENT STATE REPORT - DAMAGED TROXLER The following information was reported by facsimile. The North Carolina Department of Environment and Natural Resources reported a damaged Troxler moisture density gage during construction activities in Reidsville, NC. The NC Radiation Protection Section dispatched a health physicist to the site, the health physicist secured the damaged gage on site and conducted radiation exposure surveys to access the status of the radioactive sources. All indications and surveys support that no radiological damage occurred to those workers involved and no damage was incurred to the environment. Damage to the gage resulted in a potential loss of shielding. If the gage is mishandled the source rod will pull out. The gage was secured and the sliding block was closed. Stakeholders and responsible parties were contacted and are arranging to have the gage appropriately transferred to the manufacturer for further evaluation. Troxler Model # 3430, S/N 34504 Radiological Information: Cs-137 10 milliCi S/N 77-1449 Am/Be 40 milliCi S/N 47-29961 Survey Results: Background: 20 microR/hr three inches from gage: 8 milliR/hr After gage removed: 20 microR/hr (no indication of contamination) NC Incident Report: 05-01 The license number was not provided. | | Power Reactor | Event Number: 41348 | Facility: BROWNS FERRY Region: 2 State: AL Unit: [ ] [2] [ ] RX Type: [1] GE-4,[2] GE-4,[3] GE-4 NRC Notified By: WILLIAM BAKER HQ OPS Officer: STEVE SANDIN | Notification Date: 01/21/2005 Notification Time: 08:19 [ET] Event Date: 01/20/2005 Event Time: 23:53 [CST] Last Update Date: 01/21/2005 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION | Person (Organization): CHARLES R. OGLE (R2) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text HIGH PRESSURE COOLANT INJECTION (HPCI) DECLARED INOPERABLE BASED ON INABILITY TO VERIFY HPCI KEEP FILL FUNCTION REQUIRED BY TECHNICAL SPECIFICATIONS "At 23:53 CST Unit 2 HPCI pump suction automatically transferred from the Condensate Storage Tank to the Suppression Pool. This caused HPCI to be declared inoperable due to not meeting Technical Specification Surveillance Requirement 3.5.1.1. HPCI keep fill could not be verified so HPCI was declared inoperable. "This event is being reported pursuant to 10CFR 50.72(b)(3)(v) as 'Any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to: (D) Mitigate the consequences of an accident.'" HPCI remains inoperable pending venting of the system. The licensee is conducting an investigation to determine the root cause for the automatic transfer. The licensee informed the NRC Resident Inspector. | | Power Reactor | Event Number: 41350 | Facility: CALVERT CLIFFS Region: 1 State: MD Unit: [1] [2] [ ] RX Type: [1] CE,[2] CE NRC Notified By: DAVID SMITH HQ OPS Officer: MIKE RIPLEY | Notification Date: 01/23/2005 Notification Time: 13:51 [ET] Event Date: 01/23/2005 Event Time: 12:00 [EST] Last Update Date: 01/23/2005 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): HAROLD GRAY (R1) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text LOSS OF EMERGENCY NOTIFICATION SIREN CAPABILITY DUE TO LOSS OF POWER A significant portion of the emergency notification sirens (19 of 50) located in Calvert County, MD are out of service due to a Southern Maryland Electric Cooperative (SMECO) power outage. The licensee stated that power is expected to be restored by 1700 ET 01/23/05. The licensee will inform the NRC Resident Inspector. * * * UPDATE FROM PACE TO CROUCH @ 2022 HRS EST ON 1/23/05 * * * The out of service sirens have been tested and returned to service as of 2000 hrs. EST. The licensee has notified the NRC Resident Inspector. Notified R1DO (Gray). | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021