Event Notification Report for May 16, 2003
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 05/15/2003 - 05/16/2003 ** EVENT NUMBERS ** 39849 39851 39852 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39849 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: COMANCHE PEAK REGION: 4 |NOTIFICATION DATE: 05/15/2003| | UNIT: [1] [2] [] STATE: TX |NOTIFICATION TIME: 05:27[EDT]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 05/15/2003| +------------------------------------------------+EVENT TIME: 02:52[CDT]| | NRC NOTIFIED BY: HALL |LAST UPDATE DATE: 05/15/2003| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |WILLIAM JOHNSON R4 | |10 CFR SECTION: |MICHAEL CASE NRR | |ARPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA|RICHARD WESSMAN IRO | |AESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 A/R Y 100 Power Operation |0 Hot Standby | |2 A/R Y 100 Power Operation |0 Hot Standby | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | REACTOR TRIP FROM 100% POWER ON BOTH UNITS DUE TO TURBINE TRIP ON BOTH | | UNITS | | | | The licensee reported that a loss of power on the 345KV grid caused a | | turbine trip on both units which resulted in a reactor trip from 100% on | | both units. All rods fully inserted and no ECCS was actuated. Both units | | are currently at Mode 3 in natural circulation and stable. The auxiliary | | feed water systems started on both units to maintain steam generator levels. | | The reactor coolant temperature is being controlled by using the steam | | generator atmospheric relief valves. Since the safety systems were powered | | by an alternate offsite power supply, the 4 emergency diesels did not auto | | start, but they are operable. The licensee is investigating why they lost | | the 345KV grid. | | | | | | The NRC Resident Inspector was notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39851 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: NATIONAL RESPONSE CENTER |NOTIFICATION DATE: 05/15/2003| |LICENSEE: NORTH ANNA |NOTIFICATION TIME: 13:45[EDT]| | CITY: KNGMAN REGION: 4 |EVENT DATE: 05/14/2003| | COUNTY: SUMNER STATE: KS |EVENT TIME: 18:00[CDT]| |LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 05/15/2003| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JOHNSON R4 | | |DOUG BROADDUS NMSS | +------------------------------------------------+TIM MCGINTY DIRO | | NRC NOTIFIED BY: LYNN WARRICK |JANICE KROON EPA | | HQ OPS OFFICER: ERIC THOMAS |DAVID WHITFILL STAT | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | TRANSPORTATION INCIDENT | | | | The National Response Center sent a fax to the Operations Center regarding | | the following transportation incident: | | | | A tractor trailer carrying the reactor vessel head from North Anna power | | plant to EnviroCare in Clive, UT was sideswiped by a pickup truck being | | driven by a drunk driver near Kingman, KS on Route 42. The pickup truck | | passed the tractor trailer at approximately 80 mph, and proceeded down the | | road, where it was involved in a traffic accident. The incidental impact | | between the pickup and the tractor trailer caused a minor tear in the | | protective tarp and plastic container containing the vessel head, along with | | depositing some paint on the head itself. There was no apparent structural | | damage to the vessel head, and no apparent radioactive release into the | | atmosphere. | | | | The truck driver stopped his vehicle in Greensburg, Kansas to assess the | | condition of the vessel head. The shipper is sending a representative to | | inspect the packing material integrity. The state of Kansas will also be | | sending a representative out to the scene to assist. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39852 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: COLUMBIA GENERATING STATIREGION: 4 |NOTIFICATION DATE: 05/15/2003| | UNIT: [2] [] [] STATE: WA |NOTIFICATION TIME: 17:17[EDT]| | RXTYPE: [2] GE-5 |EVENT DATE: 05/15/2003| +------------------------------------------------+EVENT TIME: 13:15[PDT]| | NRC NOTIFIED BY: JIM FISHER |LAST UPDATE DATE: 05/15/2003| | HQ OPS OFFICER: ERIC THOMAS +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |WILLIAM JOHNSON R4 | |10 CFR SECTION: | | |DDDD 73.71(b)(1) SAFEGUARDS REPORTS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |2 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SAFEGUARDS EVENT | | | | The licensee reported a vulnerability in a safeguard system that could allow | | unauthorized or undetected access to a protected area and vital area. The | | licensee notified the NRC Resident Inspector. Contact the Headquarters | | Operations Officer for additional details. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021