Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for February 25, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           02/24/2003 - 02/25/2003



                              ** EVENT NUMBERS **



39598  39599  39600  39601  39606  39607  39612  39614  39616  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39598       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 02/19/2003|

|LICENSEE:  ENGINEERING CONSULTING SERVICES, LTD.|NOTIFICATION TIME: 16:56[EST]|

|    CITY:  HOUSTON                  REGION:  4  |EVENT DATE:        02/19/2003|

|  COUNTY:  HARRIS                    STATE:  TX |EVENT TIME:        08:45[CST]|

|LICENSE#:  L05451-000            AGREEMENT:  Y  |LAST UPDATE DATE:  02/19/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KRISS KENNEDY        R4      |

|                                                |TOM ESSIG            NMSS    |

+------------------------------------------------+JOHN DAVIDSON        IAT     |

| NRC NOTIFIED BY:  JAMES H. OGDEN, JR.          |                             |

|  HQ OPS OFFICER:  ERIC THOMAS                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT - STOLEN TROXLER MOISTURE DENSITY GAUGE               |

|                                                                              |

| "The gauge was in use on February 18, 2003. At close of business, the        |

| operator locked the gauge handle, placed it in its transportation case, and  |

| locked the case with chain and lock to a projection inside a Conex           |

| container. The Conex was then padlocked closed for the evening. When the     |

| operator arrived on-site the following morning, (February 19, 2003), he      |

| discovered that all contractor Conexes had been broken into and basically    |

| all Conexes on the site had been 'cleaned out.' The Houston Police           |

| Department was notified, arrived on site, and took statements from all       |

| personnel suffering a loss. The stolen gauge was a Troxler Model 3430,       |

| Serial No.: 20385, containing two sources: a 1.48GBq/40 milicuries (+/- 10%) |

| Am-241:Be source, Serial No.: 47-15863, and a 0.30 GBq/8 millicuries (+/-    |

| 10%) Cs-137 source, Serial No.: 75-1733. The site is believed to be located  |

| in Harris County. The gauge and sources were last leak tested on August 5.   |

| 2002, with negative leakage results."                                        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39599       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  OR DEPT OF HEALTH RAD PROTECTION     |NOTIFICATION DATE: 02/19/2003|

|LICENSEE:  LONGVIEW INSPECTION                  |NOTIFICATION TIME: 17:44[EST]|

|    CITY:  MILWAUKIE                REGION:  4  |EVENT DATE:        02/19/2003|

|  COUNTY:  CLACKAMAS                 STATE:  OR |EVENT TIME:             [PST]|

|LICENSE#:  OR-90621              AGREEMENT:  Y  |LAST UPDATE DATE:  02/19/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KRISS KENNEDY        R4      |

|                                                |                             |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  EDWIN WRIGHT                 |                             |

|  HQ OPS OFFICER:  HOWIE CROUCH                 |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT - RADIOGRAPHER RECEIVED GREATER THAN 5 REM ANNUAL     |

| LIMIT FOR 2002                                                               |

|                                                                              |

| During QA audit of licensee by Oregon Department of Human Services,          |

| Radiation Protection Services, it was determined that one radiographer       |

| employed by the licensee had exceeded his 2002 annual dose limit by          |

| approximately 800 millirem.  This discrepancy was evident by the difference  |

| between pocket ion dosimeter and TLD readings.  Oregon Radiation Protection  |

| Services continues to investigate.                                           |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39600       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  OHIO BUREAU OF RADIATION PROTECTION  |NOTIFICATION DATE: 02/20/2003|

|LICENSEE:  KEITHLY INSTRUMENTS, INC.            |NOTIFICATION TIME: 15:31[EST]|

|    CITY:  CLEVELAND                REGION:  3  |EVENT DATE:        02/19/2003|

|  COUNTY:                            STATE:  OH |EVENT TIME:             [EST]|

|LICENSE#:  GENERAL LIC.          AGREEMENT:  Y  |LAST UPDATE DATE:  02/20/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |JOHN MADERA          R3      |

|                                                |TOM ESSIG            NMSS    |

+------------------------------------------------+JOHN DAVIDSON        IAT     |

| NRC NOTIFIED BY:  MIKE SNEE                    |                             |

|  HQ OPS OFFICER:  ERIC THOMAS                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOST AIR IONIZER                                                             |

|                                                                              |

| The following report was received by fax from the Ohio Department of         |

| Health:                                                                      |

|                                                                              |

| "The Bureau received a report of a lost generally licensed air ionizer       |

| [static eliminator].  The device was [an] NRD, LLC model P-2021-8101, serial |

| # A2BP733.  The device contained a Po-210 source with an activity of 1.25    |

| [millicuries] on 2/20/03."                                                   |

|                                                                              |

| The loss was attributed to inadequate training.                              |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39601       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  OHIO BUREAU OF RADIATION PROTECTION  |NOTIFICATION DATE: 02/20/2003|

|LICENSEE:  SCOTT PROCESS SYSTEMS, INC.          |NOTIFICATION TIME: 15:32[EST]|

|    CITY:  HARTVILLE                REGION:  3  |EVENT DATE:        01/08/2003|

|  COUNTY:                            STATE:  OH |EVENT TIME:        12:00[EST]|

|LICENSE#:  OH-0332077000         AGREEMENT:  Y  |LAST UPDATE DATE:  02/20/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |JOHN MADERA          R3      |

|                                                |TOM ESSIG            NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  MIKE SNEE                    |                             |

|  HQ OPS OFFICER:  ERIC THOMAS                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ABNORMAL RADIOGRAPHY SOURCE RETRIEVAL                                        |

|                                                                              |

| The following information was received by fax from the Ohio Department of    |

| Health:                                                                      |

|                                                                              |

| "The licensee reported [an] abnormal radiography source retrieval due to a   |

| crimped guide tube.  A test piece fell on the guide tube during radiography  |

| operations in the licensee's radiography vault.  The licensee's source       |

| retrieval procedure was implemented and the source was successfully          |

| retrieved.  A total of 3 [millirem] was received by 2 individuals during     |

| this operation."                                                             |

|                                                                              |

| The source was Ir-192, 83 Curies, manufactured by AEA Technologies, model    |

| number 424-9, serial number 07686B.  The radiography camera is a Model 880   |

| manufactured by AEA Technologies, serial number D1163.                       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39606       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE: 02/20/2003|

|LICENSEE:  UNIVERSITY OF CALIFORNIA MEDICAL CENT|NOTIFICATION TIME: 19:12[EST]|

|    CITY:  ORANGE                   REGION:  4  |EVENT DATE:        02/20/2003|

|  COUNTY:                            STATE:  CA |EVENT TIME:        13:49[PST]|

|LICENSE#:  0278-30               AGREEMENT:  Y  |LAST UPDATE DATE:  02/20/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KRISS KENNEDY        R4      |

|                                                |ROBERT PIERSON       NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  GERRY FELDMAN                |                             |

|  HQ OPS OFFICER:  RICH LAURA                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| CALIFORNIA AGREEMENT STATE REPORT FOR MEDICAL EVENT AT UNIVERSITY OF         |

| CALIFORNIA                                                                   |

|                                                                              |

| "I took a call on a therapeutic misadministration from the RSO for UCIMC (LN |

| 0278-30). The incident involved the administration (via injection) of Y-90   |

| microspheres (25 microns) for the treatment of unresectable hepatic          |

| carcinoma. The intended dosage was 96.2 millicuries, and the administered    |

| dosage was approximately 38.48 millicuries (i.e., an underdose of 60%).      |

|                                                                              |

| "The delivery system consists of an injection system, connected to the vial  |

| containing the microspheres, which has one line leading to a receiving vial, |

| and another to the patient. The direction of the flow is determined by       |

| position of the valve connecting these two lines. Just beyond the vial       |

| containing the microspheres there are also two mounted detectors (like small |

| pocket chambers), which give a visual indication when the microspheres begin |

| moving out of the vial.                                                      |

|                                                                              |

| "The physicist was priming the system prior to a scheduled treatment. When   |

| the priming reaches the point that the microspheres begin to exit the vial,  |

| the valve is turned to direct the flow from the "receiving vial" to the      |

| patient. In this case, the physicist accidentally over-primed the system and |

| about 60% of the activity washed in the receiving vial. The physician, an    |

| authorized user, was also present during the treatment. They completed this  |

| treatment, and the physician is still reviewing whether it is necessary to   |

| perform another treatment to reach the prescribed dosage, or whether this    |

| treatment will be adequate as it stands.                                     |

|                                                                              |

| "The licensee is awaiting a report from the physician and physicist as to    |

| what might have caused this to occur. At the present time, they think it may |

| simply be that the physicist did not respond quickly enough to the           |

| indication on the detectors that activity was passing out of the isotope     |

| vial. That is, it may simply be a slow reflex problem. The manufacturer      |

| happened to be on site at the time of the incident, and indicated there had  |

| been two similar previous events (one allegedly at a hospital in PA), but no |

| further details on the events were obtained by the licensee."                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39607       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE: 02/20/2003|

|LICENSEE:  ALTA BATES MEDICAL CENTER            |NOTIFICATION TIME: 15:00[EST]|

|    CITY:  BERKELEY                 REGION:  4  |EVENT DATE:        02/20/2003|

|  COUNTY:                            STATE:  CA |EVENT TIME:             [PST]|

|LICENSE#:  0517-01               AGREEMENT:  Y  |LAST UPDATE DATE:  02/20/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KRISS KENNEDY        R4      |

|                                                |ROBERT PIERSON       NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  MELVA CLARIDGE               |                             |

|  HQ OPS OFFICER:  RICH LAURA                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| CALIFORNIA AGREEMENT STATE REPORT FOR MEDICAL EVENT AT ALTA BATES MEDICAL    |

| CENTER                                                                       |

|                                                                              |

| "Received a call today at about 1430 hours from [ ] who is one of Alta       |

| Bate's medical physicists (therapy department), to report a therapeutic      |

| misadministration involving I-125. The regular RSO is on leave. The patient  |

| was prescribed 0.35 millicuries I-125 for a brachytherapy procedure          |

| (prostate implant; involving 80+ seeds) on 2/19/03, but received 0.52        |

| millicuries, or an estimated 50% overdosage, because the calculation [was]   |

| done incorrectly."                                                           |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Hospital                                         |Event Number:   39612       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  FAIRFAX HOSPITAL                     |NOTIFICATION DATE: 02/24/2003|

|LICENSEE:  FAIRFAX HOSPITAL                     |NOTIFICATION TIME: 07:45[EST]|

|    CITY:  FALLS CHURCH             REGION:  2  |EVENT DATE:        02/21/2003|

|  COUNTY:  FAIRFAX                   STATE:  VA |EVENT TIME:        12:15[EST]|

|LICENSE#:  4517128-01            AGREEMENT:  N  |LAST UPDATE DATE:  02/24/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CHARLES R. OGLE      R2      |

|                                                |FRED BROWN           NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  GARY TALKINGTON              |                             |

|  HQ OPS OFFICER:  YAMIR DIAZ                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|BLO2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOST RADIOPHARMACEUTICAL DEVICE CONTAINING TECHNETIUM-99                     |

|                                                                              |

| On 2/21/03 at approximately 1030 EST, the radio-pharmacy in the Nuclear      |

| Medicine Department of the Fairfax Hospital received a shipment of radio     |

| pharmaceuticals.  As they were preparing to administer a dose to a patient,  |

| they discovered that one syringe containing 10 millicuries of                |

| Technetium-99M Mag-3 was missing.   The licensee stated that the dose was    |

| listed on the in-processing documents as received.  The licensee's current   |

| assumption is that either the dose was not actually shipped or that it was   |

| misplaced within the laboratory.    The licensee plans on continuing to      |

| investigate the whereabouts of the device.                                   |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39614       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 02/24/2003|

|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 15:36[EST]|

|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        02/24/2003|

+------------------------------------------------+EVENT TIME:        11:17[CST]|

| NRC NOTIFIED BY:  DON SMITH                    |LAST UPDATE DATE:  02/24/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHARLES R. OGLE      R2      |

|10 CFR SECTION:                                 |                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          N       0        Hot Shutdown     |0        Hot Shutdown     |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC REACTOR SCRAM DUE TO LOW REACTOR WATER LEVEL                       |

|                                                                              |

| The following information was received from the licensee via facsimile:      |

|                                                                              |

| "At 1117 [CST] on 02/24/2003 with Unit 2 in MODE 3 (Control Rods fully       |

| inserted), a full reactor scram signal (RPS) [Reactor Protection System] was |

| received due to low reactor water level.  The lowest level observed was 1.6  |

| [inches] with a scram set point of 2 [inches].  All expected PCIS [Primary   |

| Containment Isolation Systems] Isolations, GROUP 2 (RHR S/D cooling)         |

| [Residual Heat Removal], GROUP 3 (RWCU) [Reactor Water Clean-Up), GROUP 6    |

| (Ventilation) & GROUP 8 (TIP) [Transverse Incore Probes]  were received      |

| along with the auto start of 'B' CREVS [Control Room Emergency Ventilation   |

| System] and the three SBGT [Standby Gas Treatment] Trains.  This low water   |

| level event is believed to be a result of manual closure of 2C RFP [Reactor  |

| Feed Pump] Discharge valve (2-FCV-3-5) and the slow response of the RFP      |

| BYPASS valve (2-FCV-3-53)                                                    |

|                                                                              |

| "This event is reportable per 10CFR50.72 (b)(3)(iv)(A) as 'Any event or      |

| condition that results in valid actuation of RPS & PCIS as described in (1)  |

| & (2) below'."                                                               |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39616       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: BEAVER VALLEY            REGION:  1  |NOTIFICATION DATE: 02/24/2003|

|    UNIT:  [1] [] []                 STATE:  PA |NOTIFICATION TIME: 17:02[EST]|

|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        02/24/2003|

+------------------------------------------------+EVENT TIME:        15:48[EST]|

| NRC NOTIFIED BY:  PETE SENA                    |LAST UPDATE DATE:  02/25/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          UNUSUAL EVENT         |JOHN KINNEMAN        R1      |

|10 CFR SECTION:                                 |NADER MAMISH         IRO     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |TERRY REIS           NRR     |

|ACCS 50.72(b)(2)(iv)(A)  ECCS INJECTION         |ZENNOT               EPA     |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|BOB SUMMER           R1      |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|DAVE KERN            R1      |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     A/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| UNUSUAL EVENT DUE TO MAIN STEAM LINE ISOLATION WITH SAFETY INJECTION         |

|                                                                              |

| The following information was received from the licensee via facsimile:      |

|                                                                              |

| "At 1548 [EST], on 2/24/03, Beaver Valley Unit 1 experienced an automatic    |

| reactor trip and safety injection on low steam line pressure.  An automatic  |

| main steam line isolation also occurred and all three main steam line        |

| isolation valves shut.  After the automatic actions occurred, operators      |

| noted that all three steam generator pressures appeared normal. Operators    |

| were dispatched to investigate in the field and found no indications of a    |

| steam leak.                                                                  |

|                                                                              |

| "Emergency procedure E-0, Response to Reactor Trip and Safety Injection, was |

| entered at 1548.  At 1600, the Shift Manager declared an unusual event.      |

| Initial notifications to state and local agencies were complete at 1609.     |

| Per procedure E-0, after meeting Safety Injection termination criteria, the  |

| Boron Injection Tank was isolated at 1603 and Safety Injection was           |

| terminated.                                                                  |

|                                                                              |

| "Initial review of computer information revealed that closure of the 'C'     |

| main steam isolation valve is the probable cause of the reactor trip, safety |

| injection and main steam isolation.                                          |

|                                                                              |

| "The gaseous release occurred due to tritium in the secondary and the fact   |

| that the turbine driven auxiliary feed pump is in service. No protective     |

| action recommendations were made.                                            |

|                                                                              |

| "All systems and equipment functioned as designed."                          |

|                                                                              |

| Technical Support Center is staffed but not activated.  All control rods     |

| inserted into the core.  The electrical grid is stable.  Unit 1 is stable.   |

| Core cooling is being accomplished via auxiliary feedwater and steam         |

| generator atmospheric dump valves.  There is previously identified steam     |

| generator "B" tube leakage of less than 0.1 gallons per day.                 |

|                                                                              |

| The NRC Resident Inspector has been notified.                                |

|                                                                              |

| * * * UPDATE AT 1735 EST ON 2/24/03 BY HOWIE CROUCH * * *                    |

|                                                                              |

| The licensee has terminated the Unusual Event.  They have re-established a   |

| pressurizer steam bubble.  The plant and electrical grid is stable.  Decay   |

| heat removal is via auxiliary feedwater and the steam generator atmospheric  |

| steam dumps.                                                                 |

|                                                                              |

| Notified FEMA, EPA, R1DO (Kinneman), DIRO (Mamish) and NRR EO (Reis).        |

|                                                                              |

| * * * UPDATE AT 0300 EST ON 2/25/03 TO MIKE RIPLEY  FROM P. SENA * * *       |

|                                                                              |

| The licensee updated the  event classification 10 CFR sections and current   |

| plant status.                                                                |

|                                                                              |

| "At 1735 [2/24/03], the Unusual Event was terminated.  This was based upon   |

| termination of the safety injection, completion of emergency operating       |

| procedure actions, and stabilization of plant conditions.  This was          |

| previously communicated to the NRC Operations Center at 1740.                |

|                                                                              |

| "As of 0245, on 2/25/03, Unit 1 remains in mode 3.  Heat removal Is via the  |

| steam generator atmospheric steam release valves.  All main steam isolation  |

| valves remain shut as the event investigation continues.  The preliminary    |

| initiator of the event remains the inadvertent closure of "C" Main Steam     |

| Isolation Valve.  The offsite release (due to tritium activity in the        |

| secondary) has been calculated and determined to be of minimal/no effect on  |

| the public.  The projected whole body dose was 5.12E-7 mrem [millirem].      |

| This is equivalent to 3.41 E-6 percent of the yearly Offsite Dose            |

| Calculation Manual Limit."                                                   |

|                                                                              |

| Notified FEMA, EPA, R1DO (Kinneman), DIRO (Mamish) and NRR EO (Reis)         |

+------------------------------------------------------------------------------+

                    