Event Notification Report for December 17, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/16/2002 - 12/17/2002 ** EVENT NUMBERS ** 38513 39442 39447 39449 39450 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38513 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 11/23/2001| | UNIT: [1] [] [] STATE: FL |NOTIFICATION TIME: 12:30[EST]| | RXTYPE: [1] CE,[2] CE |EVENT DATE: 11/23/2001| +------------------------------------------------+EVENT TIME: 12:10[EST]| | NRC NOTIFIED BY: CHARLIE PIKE |LAST UPDATE DATE: 12/16/2002| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION TO FLORIDA STATE INVOLVING RECOVERED SEA TURTLE FROM | | UNIT 1 INTAKE STRUCTURE | | | | "A sea turtle with no external injuries but appearing to be distressed was | | recovered from the Unit 1 Intake Structure. The State Stranding Coordinator | | for sea turtles has been contacted." | | | | * * * UPDATE 11/23/01 AT 1255EST FROM CHARLIE PIKE TO S. SANDIN * * * | | | | "Turtle has died." | | | | The licensee informed both the State of Florida and the NRC Resident | | Inspector. | | | | * * * UPDATE 1413EST ON 12/3/01 FROM JACK BREEN TO FANGIE JONES * * * | | | | At approximately 1215 EST on 12/3/01, a report was made to the Florida | | Department of Fish and Wildlife concerning the recovery of an injured sea | | turtle from the plant's intake canal. The turtle was a green sea turtle in | | the intake canal that appeared distressed and looked to have a wound from a | | boat motor on its back. It will be transferred to the State for | | rehabilitation. | | | | The licensee plans to notify the NRC resident inspector. Notified | | R2DO(MacAlpine). | | | | * * * UPDATE 1333EST ON 12/15/01 FROM JACK BREEN TO JOHN MACKINNON * * * | | | | At approximately 1215 EST on 12/15/01, a report was made to the Florida | | Department of Fish and Wildlife Conservation Commission to pick up a Green | | Turtle for rehabilitation. The Green Turtle was taken from the plant's | | intake canal, and the turtle appears to have shark bites. | | | | The licensee plans to notify the NRC resident inspector. Notified R2DO | | (Chuck Ogle). | | | | * * * UPDATE 1450EST ON 01/06/02 FROM TULLIDGE TO JOHN MACKINNON * * * | | | | At 1350EST, a notification to the State of Florida Department of Fish and | | Wildlife Conservation Commission was made due to finding an injured | | Loggerhead sea turtle in Unit 1 intake. The sea turtle was transported | | offsite for rehabilitation. R2DO (Tom Decker) notified. | | | | The licensee notified the NRC Resident Inspector. | | | | ***UPDATE 1330EST ON 4/23/02 FROM JACK BREEN TO RICH LAURA*** | | | | The licensee rescued a Loggerhead sea turtle from the intake canal. The | | Florida Fish and Wildlife Conservation Commission was notified, and the | | turtle was turned over for rehabilitation. | | | | The NRC Resident Inspector was informed. Notified R2DO (B. Bonser). | | | | ***UPDATE 1241EDT ON 5/29/02 FROM DAVE WILLIAMS TO RICHARD LAURA*** | | | | The licensee reported that an offsite notification was made to the Florida | | Fish and Wildlife Conservation Commission concerning the discovery of a live | | loggerhead sea turtle found in the plant's intake canal. The turtle was | | lethargic and was sent for rehabilitation. | | | | The NRC Resident Inspector was informed. Notified R2DO (K. Landis). | | | | ***** UPDATE AT 1125 EDT ON 06/01/02 FROM CHARLES MARPLE TO LEIGH TROCINE | | ***** | | | | The following text is a portion of a facsimile received from the licensee: | | | | "At 1020 on 06/01/02, a notification was made to the Florida Fish and | | Wildlife Conservation Commission regarding a weak and emaciated Loggerhead | | turtle found in the plant intake barrier net. The turtle will be sent | | off-site to the Marine Life Center for Rehabilitation." | | | | The licensee notified the NRC resident inspector. The NRC operations | | officer notified the R2DO (Kerry Landis). | | | | *****UPDATE AT 11:53 EDT ON 6/2/02 FROM MARPLE TO LAURA****** | | | | "A notification was made to the Florida Fish and Wildlife Conservation | | Commission regarding a dead small green sea turtle found in the tangle net. | | The turtle will be maintained on ice for a postmortem examination." | | | | The NRC resident inspector was notified. Notified R2DO (K. Landis) | | | | *****UPDATE AT 12:45 EDT ON 7/18/02 FROM BREEN TO LAURA****** | | | | A notification was made to the State regarding a dead green sea turtle that | | was removed from the intake canal. | | | | The NRC resident inspector will be notified. | | | | Notified R2DO (C. Payne | | | | ***UPDATE AT 1045 EDT ON 10/20/02 FROM KORTH TO NORRIS*** | | | | A Loggerhead turtle was retrieved from the plant's intake canal. The turtle | | was in need of rehabilitation. Per the plant's turtle permit, the Florida | | Fish and Wildlife Conservation Commission (FWCC) was notified at 0927 EDT. | | | | The NRC Resident Inspector has been notified. | | | | Notified R2DO (Barr) | | | | * * * UPDATE AT 1338 EDT ON 10/22/02 FROM KELLY KORTH TO GERRY WAIG * * * | | | | A Loggerhead turtle was retrieved from the plant's intake canal. The turtle | | was in need of rehabilitation. Per the plant's turtle permit, the Florida | | Fish and Wildlife Conservation Commission (FWCC) was notified at 1250 EDT. | | | | The NRC Resident Inspector will be notified by the licensee. | | | | Notified R2DO (Bob Haag) | | | | * * * UPDATE ON 11/22/2002 @ 1821 BY FIELDS TO GOULD * * * | | | | The licensee notified the Florida Department of Environmental Protection of | | the recovery of a distressed loggerhead sea turtle from their intake canal. | | The turtle was taken to a rehabilitation facility. | | | | The NRC Resident inspector will be notified. Notified R2DO (David Ayres). | | | | * * * UPDATE AT 1320 EST ON 12/16/02 FROM BILL PARKS TO GERRY WAIG * * * | | | | "On 12-16-02, two loggerhead turtles were retrieved from the plant's intake | | canal. The turtles were determined to be in need of rehabilitation. The | | injuries to the turtles are not causal to plant operation. Per the plant's | | turtle permit, the Florida Fish and Wildlife Conservation Commission (FWCC) | | was notified at 1230 EST. This non-emergency notification is being made | | pursuant to 10 CFR 50.72(b)(2)(xi) due to the notification of FWCC." | | | | The NRC Resident inspector will be notified. Notified R2DO (Mike Ernstes). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39442 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: IOWA DEPARTMENT OF PUBLIC HEALTH |NOTIFICATION DATE: 12/12/2002| |LICENSEE: IOWA METHODIST MEDICAL CENTER |NOTIFICATION TIME: 15:57[EST]| | CITY: DES MOINES REGION: 3 |EVENT DATE: 12/03/2002| | COUNTY: STATE: IA |EVENT TIME: [CST]| |LICENSE#: 0310-1-77-HDR AGREEMENT: Y |LAST UPDATE DATE: 12/12/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |PATRICK HILAND R3 | | |JIM LYNCH R3 | +------------------------------------------------+TOM ESSIG NMSS | | NRC NOTIFIED BY: GEORGE JOHNS | | | HQ OPS OFFICER: MIKE NORRIS | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT INVOLVING MEDICAL MISADMINISTRATION | | | | "The licensee reported a medical misadministration involving a High Dose | | Rate Afterloader. The patient treatment plan required 20 steps in a | | treatment with the stepping distance of 0.5 centimeters. The licensee | | reported that the stepping distance was actually 1.0 centimeter. (The cause | | of the deviation has not yet been determined.) The deviation resulted in | | an unplanned dose to an unintended site. The exposure was to 10 centimeters | | outside the planned treatment area. The dose has not yet been determined." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Transportation |Event Number: 39447 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: SYNCOR INTERNATIONAL CORP. |NOTIFICATION DATE: 12/15/2002| |LICENSEE: SYNCOR INTERNATIONAL CORP. |NOTIFICATION TIME: 08:40[EST]| | CITY: GLASTONBURY REGION: 1 |EVENT DATE: 12/15/2002| | COUNTY: STATE: CT |EVENT TIME: 05:00[EST]| |LICENSE#: 04-26507-01MD AGREEMENT: N |LAST UPDATE DATE: 12/16/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |DAVID LEW R1 | | |TOM ESSIG NMSS | +------------------------------------------------+CREWS DOT | | NRC NOTIFIED BY: MATT SVEJK | | | HQ OPS OFFICER: ARLON COSTA | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | Tc-99m CANISTERS UNDAMAGED DURING TRANSPORTATION ACCIDENT | | | | The NRC Operations Center was notified by the Connecticut Department of | | Environmental Protection (CT DEP) that an vehicle accident involving a | | Syncor delivery to local hospitals and pharmacies had occurred. A follow-up | | discussion with the Radiation Safety Officer (RSO) for Syncor International | | Corporation located at 628 Hebron Avenue, Bldg.4, Glastonbury, CT 06033, | | provided detailed information related to the incident. The company vehicle | | (pickup truck) accidentally rolled over after encountering a patch of black | | ice. Eight canisters (ammo box style) were ejected from the vehicle bed | | during the accident at Route 6 and State Road 384 in Coventry, Connecticut. | | The company driver was in the process of picking up and delivering the | | canisters which house Tc-99m syringes (unit dose) that are enclosed in lead | | pigs. Both the local police and fire departments and the CT DEP responded | | to the accident which happened at approximately 0500 EST on 12/15/02. The | | driver was taken to a local hospital for routine x-rays and treatment. The | | initial assessment of the incident was that the canisters were not breached. | | No contamination was detected by the first responders. Syncor will follow | | up with measurements of the swipes using Multi-Channel Analyzer | | methodology. | | | | * * * UPDATE AT 10:18 ON 12/15/02 FROM MATT SVEJK TO ARLON COSTA * * * | | | | The test results of the wiped canisters using a Multi-Channel Analyzer did | | not indicate any counts above background. The total Tc-99m activity of the | | five active canisters (the other three were return canisters) was | | approximately 1,137 millicuries (assay estimate as of 0500 EST on 12/15/02). | | Notified R1DO(Lew) and NMSS(Essig). | | | | UPDATE AT 1433 EST ON 12/16/02 FROM KORY KODIMER TO GERRY WAIG | | | | Mr. Kodimer, Health Physics Program Manager, Syncor International Corp., | | Woodland Hills, CA, called to report that NRC Region 1 and 4 have been | | contacted by the Syncor corporate office. Additionally, Mr. Kodimer reported | | that all 8 canisters have been returned to the licensee's (Syncor | | International Corp.) Glastonbury, CT facility. | | | | Notified R4DO (Tom Andrews) and NMSS (Charles Cox) | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 39449 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: GEORGIA DEPT. OF NATURAL RESOURCES |NOTIFICATION DATE: 12/16/2002| |LICENSEE: MACTEC ENGINEERING AND CONSULTING |NOTIFICATION TIME: 11:03[EST]| | CITY: ATLANTA REGION: 2 |EVENT DATE: 12/16/2002| | COUNTY: STATE: GA |EVENT TIME: [EST]| |LICENSE#: GA-1458-1 AGREEMENT: Y |LAST UPDATE DATE: 12/16/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MIKE ERNSTES R2 | | |FRED BROWN NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: LIZ SEALE | | | HQ OPS OFFICER: ARLON COSTA | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT INVOLVING STOLEN GAUGE | | | | Georgia Department of Natural Resources reported to the NRC Operations | | Center via fax on 12/16/02 at 10:37 a.m. that a Niton XL-309 gauge was | | stolen on 12/9/02 during overnight hours from the trunk of an automobile | | while in a hotel parking lot. The gauge contained seven millicuries of | | Cd-109. The Licensee was instructed to notify the FBI and was given the | | telephone number for the Miami Beach FBI Office. | | | | The Georgia Department of Natural Resources also notified the Florida | | Radiation Control Program and NRC Region II. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39450 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 12/16/2002| | UNIT: [] [2] [] STATE: NY |NOTIFICATION TIME: 18:17[EST]| | RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 12/16/2002| +------------------------------------------------+EVENT TIME: 15:47[EST]| | NRC NOTIFIED BY: MITCHEL ALMETER |LAST UPDATE DATE: 12/16/2002| | HQ OPS OFFICER: GERRY WAIG +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |DANIEL HOLODY R1 | |10 CFR SECTION: |WILLIAM BECKNER NRR | |ARPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 A/R Y 60 Power Operation |0 Hot Shutdown | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | NINE MILE POINT UNIT 2 REACTOR SCRAM ON HIGH REACTOR PRESSURE | | | | "Failure of main generator stator water cooling temperature control valve | | resulted in loss of generator stator water cooling and main generator | | runback signal. Reactor power reduction was initiated with reactor | | recirculation flow and continued with insertion of control rods. Turbine | | bypass valves opened as result of main generator runback signal. Reactor | | protection system auto actuated on high reactor pressure [1052 psig] at 1547 | | [EST], 12/16/02. [The maximum reactor pressure observed during the | | transient was 1055 psig.] All control rods fully inserted . No safety relief | | valves opened. No ECCS systems actuated. Reactor water level being | | controlled by reactor core isolation cooling and condensate/ feedwater. | | Reactor pressure [is] being controlled by turbine bypass valves." | | | | The licensee has notified the NRC Resident Inspector of this event. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021