Event Notification Report for December 06, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/05/2002 - 12/06/2002 ** EVENT NUMBERS ** 39415 39417 39422 39423 39424 39425 +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39415 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ARKANSAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 12/02/2002| |LICENSEE: CARTI-UAMS |NOTIFICATION TIME: 15:50[EST]| | CITY: LITTLE ROCK REGION: 4 |EVENT DATE: 11/20/2002| | COUNTY: STATE: AR |EVENT TIME: [CST]| |LICENSE#: 930-BP-04-09 AGREEMENT: Y |LAST UPDATE DATE: 12/02/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JONES R4 | | |THOMAS ESSIG NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JARED THOMPSON | | | HQ OPS OFFICER: ERIC THOMAS | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT INVOLVING MEDICAL MISADMINISTRATION | | | | "A medical misadministration was reported to Arkansas Department of Health | | Radiation Control and Emergency Management's Radioactive Materials Program | | by CARTI-UAMS on November 27, 2002 via a voice mail message. Due to the | | Thanksgiving holiday, the message was not reviewed by the Department until | | December 2, 2002. | | | | "According to the voice mail message and the preliminary telephone interview | | with the licensee, the misadministration resulted from the incorrect | | positioning of a treatment tandem within the cervical treatment cylinder. | | As a result, the treatment was delivered approximately 3 cm inferior to the | | intended position. The incorrect positioning of the tandem that occurred | | during first treatment on November 20, 2002 was noted when the medical | | physics staff was reviewing the position verification film for the second | | treatment on November 27, 2002. | | | | "An onsite investigation will be conducted by the Department on December 2, | | 2002. An updated report of the medical misadministration will be provided | | following this investigation." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39417 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: CALIFORNIA RADIATION CONTROL PRGM |NOTIFICATION DATE: 12/02/2002| |LICENSEE: GEOSOILS |NOTIFICATION TIME: 17:42[EST]| | CITY: VAN NUYS REGION: 4 |EVENT DATE: 11/29/2002| | COUNTY: STATE: CA |EVENT TIME: 09:00[PST]| |LICENSE#: CA 4741-19 AGREEMENT: Y |LAST UPDATE DATE: 12/02/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JONES R4 | | |THOMAS ESSIG NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: BARBARA HAMRICK | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE | | | | "This is to report a stolen moisture density gauge in the State of | | California (California incident number 112902). | | | | "The licensee is Geosoils in Van Nuys, California (California license number | | 4741-19). The gauge was reported stolen via a voice-mail message left | | Friday morning, November 29, 2002. The State offices were closed that day | | for the Thanksgiving holiday. | | | | "The gauge was stolen some time mid-morning on November 29, 2002, from the | | back of a pick-up truck, parked at a residence in the city of Gardena. The | | chain securing the gauge package to the truck was cut. The local police | | took a report. The licensee will be running an ad offering a reward for the | | return of the gauge for the next 10 days in the local newspaper. | | | | "This is all the information we have at the present time. We are awaiting a | | report from the licensee, confirming the activity and nuclide(s) in the | | gauge, as well as the serial number, and other information." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39422 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: CATAWBA REGION: 2 |NOTIFICATION DATE: 12/05/2002| | UNIT: [1] [2] [] STATE: SC |NOTIFICATION TIME: 01:52[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 12/05/2002| +------------------------------------------------+EVENT TIME: 00:43[EST]| | NRC NOTIFIED BY: JIMMY BURGESS |LAST UPDATE DATE: 12/05/2002| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |ANNE BOLAND R2 | |10 CFR SECTION: | | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF OFFSITE EMERGENCY SIRENS DUE TO ADVERSE WEATHER | | | | "Twenty-four (24) emergency sirens out-of-service due to loss of power | | because of ice storm. These sirens have been out-of-service more than one | | hour and preparations underway to restore to service." | | | | The licensee will inform state/local agencies and the NRC resident | | inspector. | | | | | | * * * UPDATE ON 12/05/02 @ 1028 BY BRADLEY TO GOULD * * * | | | | The site currently has 47 of 89 sirens out of service and has placed their | | backup route alerting system in service in the affected counties. They also | | have a reverse 911 callup system in place in the county that the site is | | located. | | | | Present estimates for returning power to the counties and thus to the sirens | | is approximately one or two days. | | | | The Resident Inspector was notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39423 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 12/05/2002| | UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 02:00[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 12/05/2002| +------------------------------------------------+EVENT TIME: 01:45[EST]| | NRC NOTIFIED BY: TONY COOK |LAST UPDATE DATE: 12/05/2002| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |ANNE BOLAND R2 | |10 CFR SECTION: | | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF OFFSITE EMERGENCY SIRENS DUE TO ADVERSE WEATHER | | | | "Any event that results in a major loss of emergency assessment capability, | | offsite response capability; or offsite communications capability. | | Currently greater than 16 ENS sirens are inoperable which is greater than | | 25% of siren capability." | | | | The licensee will inform local agencies and the NRC resident inspector. | | | | * * * * UPDATE FROM LICENSEE TO MIKE RIPLEY AT 1647 EST 12/5/02 * * * * | | | | The licensee stated that crews are continuing to restore all ENS sirens to | | service and that currently only 13 ENS sirens are inoperable which is less | | than the 25% of siren capability criteria. | | | | Notified R2DO (Robert Haag) | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39424 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: HARRIS REGION: 2 |NOTIFICATION DATE: 12/05/2002| | UNIT: [1] [] [] STATE: NC |NOTIFICATION TIME: 08:45[EST]| | RXTYPE: [1] W-3-LP |EVENT DATE: 12/05/2002| +------------------------------------------------+EVENT TIME: 03:07[EST]| | NRC NOTIFIED BY: CHERIE L. GRIFFITH |LAST UPDATE DATE: 12/05/2002| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |BRIAN BONSER R2DO | |10 CFR SECTION: | | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF OFFSITE EMERGENCY SIRENS DUE TO ADVERSE WEATHER | | | | "At 0307, greater than 20% of the Off Site Emergency Sirens were inoperable | | due to loss of power during the current Ice Storm. Currently 59 of 81 | | sirens are out of service. This requires an 8 hour notification per 10CFR | | 50.72. Additionally, at 0645, Lee County had gone one hour without any | | operable sirens. At 0830, Harnett County had gone one hour without any | | operable sirens. Transmission is aware and are prioritizing repairs." | | | | The licensee informed state/local agencies and the NRC resident inspectors. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Hospital |Event Number: 39425 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: LEHEIGH VALLEY HOSPITAL |NOTIFICATION DATE: 12/05/2002| |LICENSEE: LEHEIGH VALLEY HOSPITAL |NOTIFICATION TIME: 12:10[EST]| | CITY: ALLENTOWN REGION: 1 |EVENT DATE: 12/04/2002| | COUNTY: STATE: PA |EVENT TIME: 17:00[EST]| |LICENSE#: 37-01548-01 AGREEMENT: N |LAST UPDATE DATE: 12/05/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MICHELE EVANS R1 | | |ROBERT PIERSON NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: CYNTHIA GOODMAN | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |LOTH 35.3045(a)(3) DOSE TO OTHER SITE > SP| | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MEDICAL EVENT - DOSE TO SKIN OTHER THAN TREATMENT SITE | | | | The attending physician, also the Radiation Oncologist, discovered that one | | of the catheters containing 3 seeds of iridium-192 was out of position. The | | treatment was a 48 hour dose to the lip area for a carcinoma. The physician | | had checked the location at 1700 EST on 12/3/02 and when checking at 1700 | | EST on 12/4/02 discovered the one catheter under the patient under a bed | | pad. The estimated dose to the skin of the back, conservatively using the | | entire 24 hours, is 240 rem. The possible result is some erythmea, | | reddening of the skin. The patient has been informed. The actual treatment | | site dose is only 4.3 % under the planned so no further treatment is | | necessary or reportable. | | | | The Radiation Safety Officer intends to notify NRC Region 1. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021