Event Notification Report for October 23, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 10/22/2002 - 10/23/2002 ** EVENT NUMBERS ** 38513 39293 39306 39310 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38513 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 11/23/2001| | UNIT: [1] [] [] STATE: FL |NOTIFICATION TIME: 12:30[EST]| | RXTYPE: [1] CE,[2] CE |EVENT DATE: 11/23/2001| +------------------------------------------------+EVENT TIME: 12:10[EST]| | NRC NOTIFIED BY: CHARLIE PIKE |LAST UPDATE DATE: 10/22/2002| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION TO FLORIDA STATE INVOLVING RECOVERED SEA TURTLE FROM | | UNIT 1 INTAKE STRUCTURE | | | | "A sea turtle with no external injuries but appearing to be distressed was | | recovered from the Unit 1 Intake Structure. The State Stranding Coordinator | | for sea turtles has been contacted." | | | | * * * UPDATE 11/23/01 AT 1255EST FROM CHARLIE PIKE TO S. SANDIN * * * | | | | "Turtle has died." | | | | The licensee informed both the State of Florida and the NRC Resident | | Inspector. | | | | * * * UPDATE 1413EST ON 12/3/01 FROM JACK BREEN TO FANGIE JONES * * * | | | | At approximately 1215 EST on 12/3/01, a report was made to the Florida | | Department of Fish and Wildlife concerning the recovery of an injured sea | | turtle from the plant's intake canal. The turtle was a green sea turtle in | | the intake canal that appeared distressed and looked to have a wound from a | | boat motor on its back. It will be transferred to the State for | | rehabilitation. | | | | The licensee plans to notify the NRC resident inspector. Notified | | R2DO(MacAlpine). | | | | * * * UPDATE 1333EST ON 12/15/01 FROM JACK BREEN TO JOHN MACKINNON * * * | | | | At approximately 1215 EST on 12/15/01, a report was made to the Florida | | Department of Fish and Wildlife Conservation Commission to pick up a Green | | Turtle for rehabilitation. The Green Turtle was taken from the plant's | | intake canal, and the turtle appears to have shark bites. | | | | The licensee plans to notify the NRC resident inspector. Notified R2DO | | (Chuck Ogle). | | | | * * * UPDATE 1450EST ON 01/06/02 FROM TULLIDGE TO JOHN MACKINNON * * * | | | | At 1350EST, a notification to the State of Florida Department of Fish and | | Wildlife Conservation Commission was made due to finding an injured | | Loggerhead sea turtle in Unit 1 intake. The sea turtle was transported | | offsite for rehabilitation. R2DO (Tom Decker) notified. | | | | The licensee notified the NRC Resident Inspector. | | | | ***UPDATE 1330EST ON 4/23/02 FROM JACK BREEN TO RICH LAURA*** | | | | The licensee rescued a Loggerhead sea turtle from the intake canal. The | | Florida Fish and Wildlife Conservation Commission was notified, and the | | turtle was turned over for rehabilitation. | | | | The NRC Resident Inspector was informed. Notified R2DO (B. Bonser). | | | | ***UPDATE 1241EDT ON 5/29/02 FROM DAVE WILLIAMS TO RICHARD LAURA*** | | | | The licensee reported that an offsite notification was made to the Florida | | Fish and Wildlife Conservation Commission concerning the discovery of a live | | loggerhead sea turtle found in the plant's intake canal. The turtle was | | lethargic and was sent for rehabilitation. | | | | The NRC Resident Inspector was informed. Notified R2DO (K. Landis). | | | | ***** UPDATE AT 1125 EDT ON 06/01/02 FROM CHARLES MARPLE TO LEIGH TROCINE | | ***** | | | | The following text is a portion of a facsimile received from the licensee: | | | | "At 1020 on 06/01/02, a notification was made to the Florida Fish and | | Wildlife Conservation Commission regarding a weak and emaciated Loggerhead | | turtle found in the plant intake barrier net. The turtle will be sent | | off-site to the Marine Life Center for Rehabilitation." | | | | The licensee notified the NRC resident inspector. The NRC operations | | officer notified the R2DO (Kerry Landis). | | | | *****UPDATE AT 11:53 EDT ON 6/2/02 FROM MARPLE TO LAURA****** | | | | "A notification was made to the Florida Fish and Wildlife Conservation | | Commission regarding a dead small green sea turtle found in the tangle net. | | The turtle will be maintained on ice for a postmortem examination." | | | | The NRC resident inspector was notified. Notified R2DO (K. Landis) | | | | *****UPDATE AT 12:45 EDT ON 7/18/02 FROM BREEN TO LAURA****** | | | | A notification was made to the State regarding a dead green sea turtle that | | was removed from the intake canal. | | | | The NRC resident inspector will be notified. | | | | Notified R2DO (C. Payne | | | | ***UPDATE AT 1045 EDT ON 10/20/02 FROM KORTH TO NORRIS*** | | | | A Loggerhead turtle was retrieved from the plant's intake canal. The turtle | | was in need of rehabilitation. Per the plant's turtle permit, the Florida | | Fish and Wildlife Conservation Commission (FWCC) was notified at 0927 EDT. | | | | The NRC Resident Inspector has been notified. | | | | Notified R2DO (Barr) | | | | * * * UPDATE AT 1338 EDT ON 10/22/02 FROM KELLY KORTH TO GERRY WAIG * * * | | | | A Loggerhead turtle was retrieved from the plant's intake canal. The turtle | | was in need of rehabilitation. Per the plant's turtle permit, the Florida | | Fish and Wildlife Conservation Commission (FWCC) was notified at 1250 EDT. | | | | The NRC Resident Inspector will be notified by the licensee. | | | | Notified R2DO (Bob Haag) | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39293 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: OR DEPT OF HEALTH RAD PROTECTION |NOTIFICATION DATE: 10/16/2002| |LICENSEE: GEOCON NORTHWEST INC |NOTIFICATION TIME: 14:04[EDT]| | CITY: BEAVERTON REGION: 4 |EVENT DATE: 10/16/2002| | COUNTY: STATE: OR |EVENT TIME: [PDT]| |LICENSE#: ORE-90921 AGREEMENT: Y |LAST UPDATE DATE: 10/22/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |GREG PICK R4 | | |THOMAS ESSIG NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: TERRY LINDSEY | | | HQ OPS OFFICER: GERRY WAIG | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | STOLEN VEHICLE AND TROXLER MOISTURE DENSITY GAUGE | | | | On the evening 10/15/02 or the early morning of 10/16/02 a 1987 red Toyota 4 | | Runner storing a Troxler moisture density gauge was stolen from the | | residence of an authorized user. The local police were notified of the theft | | at approximately 0800 PDT and the Oregon Radiation Protection Services at | | 0855 PDT on 10/16/02. The gauge is a Troxler model 3440 serial number 26707 | | and contains an 8 millicurie Cs-137 source, serial number 75-9841, and a 40 | | millicurie Am-241:Be source, serial number 47-23181. The licensee is GEOCON | | Northwest Inc., 8380 Southwest Ave., Beaverton, OR 97008. Oregon Radiation | | Protection Services will notify NRC Region 4 and plans to make a press | | release for this event. The Oregon event number for this incident is | | 020041. | | | | * * * UPDATE ON 10/22/02 AT 2329 FROM TERRY LINDSEY TO GERRY WAIG * * * | | | | Mr. Terry Lindsey, Program Manager, Oregon Radiation Protection Services | | called to report that the stolen Troxler moisture density gauge model #3440, | | serial #26707 was recovered by the Portland, OR Police Department on | | 10/22/02 at 1735 PDT . A HAZMAT team was called to the scene and the gauge | | was intact. Additional follow-up is planned for tomorrow morning (10/23/02). | | The owner of the gauge, GEOCON Northwest Inc., has been notified of the | | recovery. | | | | Notified R4DO (Anthony Gody) and NMSS (Mel Leach) | +------------------------------------------------------------------------------+ !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 39306 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: STORA NESO |NOTIFICATION DATE: 10/21/2002| |LICENSEE: STORA NESO |NOTIFICATION TIME: 16:18[EDT]| | CITY: WISCONSIN RAPIDS REGION: 3 |EVENT DATE: 10/21/2002| | COUNTY: STATE: WI |EVENT TIME: [CDT]| |LICENSE#: GL 132 AGREEMENT: N |LAST UPDATE DATE: 10/22/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |THOMAS KOZAK R3 | | |M. WAYNE HODGES NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: CHARLES CHAPMAN | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | FAILED LEAK TEST ON STATIC GUN GOING TO DISPOSAL | | | | Stora Neso was in the process of disposing of a Chapman Manufacturing (no | | longer in business) static gun containing 200 millicuries of tritium (when | | manufactured in September 1965). Stora Neso does not have a requirement to | | leak test the static gun, which had not been used for a long time. The | | disposal site requested a leak test. The static gun was wipe tested and the | | following results were obtained: wet wipe read 0.311409 microcuries and the | | dry wipe read 0.0556399 microcuries, the action level is 0.005 microcuries. | | They have taken additional wipes of the gun and container whose results are | | not available at the time of the report. They have also contacted a testing | | company to determine what the wipes are actually were measuring. | | | | * * * RETRACTION ON 10/22/02 AT 1210 EDT FROM CHUCK CHAPMAN TO GERRY WAIG | | | | After discussion between the licensee and NRC Region 3 personnel, the | | licensee retracted this event on 10/22/02 at 1210 EDT. Notified R3DO | | (Christine Lipa) and NMSS (Doug Broaddus). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39310 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 10/22/2002| | UNIT: [] [] [3] STATE: AL |NOTIFICATION TIME: 17:34[EDT]| | RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 10/22/2002| +------------------------------------------------+EVENT TIME: 12:52[CDT]| | NRC NOTIFIED BY: JOE BENNETT |LAST UPDATE DATE: 10/22/2002| | HQ OPS OFFICER: GERRY WAIG +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |ROBERT HAAG R2 | |10 CFR SECTION: | | |AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | | |AINB 50.72(b)(3)(v)(B) POT RHR INOP | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | | | | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF HIGH PRESSURE COOLANT INJECTION SYSTEM | | | | "At 1252 [CDT] on 10/22/02, during troubleshooting activities, a loss of the | | Unit 3 Division II ECCS inverter occurred. This resulted in a loss of the | | High Pressure Coolant Injection system (HPCI) due to a loss of power to the | | flow indicating controller. This event is reportable within 8 hours per | | 10CFR 50.72(b)(3)(v) and requires a 60 day written report per 10CFR | | 50.73(a)(2)(v)." | | | | The licensee has notified the NRC Resident Inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021