Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for July 19, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/18/2002 - 07/19/2002

                              ** EVENT NUMBERS **

38513  38602  39063  39064  39065  39069  39070  
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38513       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 11/23/2001|
|    UNIT:  [1] [] []                 STATE:  FL |NOTIFICATION TIME: 12:30[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        11/23/2001|
+------------------------------------------------+EVENT TIME:        12:10[EST]|
| NRC NOTIFIED BY:  CHARLIE PIKE                 |LAST UPDATE DATE:  07/18/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO FLORIDA STATE INVOLVING RECOVERED SEA TURTLE
FROM    |
| UNIT 1 INTAKE STRUCTURE                                                      |
|                                                                              |
| "A sea turtle with no external injuries but appearing to be distressed was   |
| recovered from the Unit 1 Intake Structure.  The State Stranding Coordinator |
| for sea turtles has been contacted."                                         |
|                                                                              |
| * * * UPDATE 11/23/01 AT 1255EST FROM CHARLIE PIKE TO S. SANDIN * * *        |
|                                                                              |
| "Turtle has died."                                                           |
|                                                                              |
| The licensee informed both the State of Florida and the NRC Resident         |
| Inspector.                                                                   |
|                                                                              |
| * * * UPDATE 1413EST ON 12/3/01 FROM JACK BREEN TO FANGIE JONES * * *        |
|                                                                              |
| At approximately 1215 EST on 12/3/01, a report was made to the Florida       |
| Department of Fish and Wildlife concerning the recovery of an injured sea    |
| turtle from the plant's intake canal.  The turtle was a green sea turtle in  |
| the intake canal that appeared distressed and looked to have a wound from a  |
| boat motor on its back.  It will be transferred to the State for             |
| rehabilitation.                                                              |
|                                                                              |
| The licensee plans to notify the NRC resident inspector.  Notified           |
| R2DO(MacAlpine).                                                             |
|                                                                              |
| * * * UPDATE 1333EST ON 12/15/01 FROM JACK BREEN TO JOHN MACKINNON * * *     |
|                                                                              |
| At approximately 1215 EST on 12/15/01, a report was made to the Florida      |
| Department of Fish and Wildlife Conservation Commission to pick up a Green   |
| Turtle for rehabilitation. The Green Turtle was taken from the plant's       |
| intake canal, and the turtle appears to have shark bites.                    |
|                                                                              |
| The licensee plans to notify the NRC resident inspector.  Notified R2DO      |
| (Chuck Ogle).                                                                |
|                                                                              |
| * * * UPDATE 1450EST ON 01/06/02 FROM TULLIDGE TO JOHN MACKINNON * * *       |
|                                                                              |
| At 1350EST, a notification to the State of Florida Department of Fish and    |
| Wildlife Conservation Commission was made due to finding an injured          |
| Loggerhead sea turtle in Unit 1 intake. The sea turtle was transported       |
| offsite for rehabilitation. R2DO (Tom Decker) notified.                      |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| ***UPDATE 1330EST ON 4/23/02 FROM JACK BREEN TO RICH LAURA***                |
|                                                                              |
| The licensee rescued a  Loggerhead sea turtle from the intake canal.  The    |
| Florida Fish and Wildlife Conservation Commission was notified, and the      |
| turtle was turned over for rehabilitation.                                   |
|                                                                              |
| The NRC Resident Inspector was informed.  Notified R2DO (B. Bonser).         |
|                                                                              |
| ***UPDATE 1241EDT ON 5/29/02 FROM DAVE WILLIAMS TO RICHARD LAURA***          |
|                                                                              |
| The licensee reported that an offsite notification was made to the Florida   |
| Fish and Wildlife Conservation Commission concerning the discovery of a live |
| loggerhead sea turtle found in the plant's intake canal.  The turtle was     |
| lethargic and was sent for rehabilitation.                                   |
|                                                                              |
| The NRC Resident Inspector was informed.  Notified R2DO (K. Landis).         |
|                                                                              |
| ***** UPDATE AT 1125 EDT ON 06/01/02 FROM CHARLES MARPLE TO LEIGH TROCINE   
|
| *****                                                                        |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At 1020 on 06/01/02, a notification was made to the Florida Fish and        |
| Wildlife Conservation Commission regarding a weak and emaciated Loggerhead   |
| turtle found in the plant intake barrier net.  The turtle will be sent       |
| off-site to the Marine Life Center for Rehabilitation."                      |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations        |
| officer notified the R2DO (Kerry Landis).                                    |
|                                                                              |
| *****UPDATE AT 11:53 EDT ON 6/2/02 FROM MARPLE TO LAURA******                |
|                                                                              |
| "A notification was made to the Florida Fish and Wildlife Conservation       |
| Commission regarding a dead small green sea turtle found in the tangle net.  |
| The turtle will be maintained on ice for a postmortem examination."          |
|                                                                              |
| The NRC resident inspector was notified. Notified R2DO (K. Landis)           |
|                                                                              |
| *****UPDATE AT 12:45 EDT ON 7/18/02 FROM BREEN TO LAURA******                |
|                                                                              |
| A notification was made to the State regarding a dead green sea turtle that  |
| was removed from the intake canal.                                           |
|                                                                              |
| The NRC resident inspector will be notified.                                 |
|                                                                              |
| Notified R2DO (C. Payne)                                                     |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38602       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER            REGION:  2  |NOTIFICATION DATE: 01/01/2002|
|    UNIT:  [3] [] []                 STATE:  FL |NOTIFICATION TIME: 10:08[EST]|
|   RXTYPE: [3] B&W-L-LP                         |EVENT DATE:        01/01/2002|
+------------------------------------------------+EVENT TIME:        09:19[EST]|
| NRC NOTIFIED BY:  BILL BANDHAUER               |LAST UPDATE DATE:  07/18/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANNE BOLAND          R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE RESCUED SEA TURTLE                                  |
|                                                                              |
| EN #37902 started the biennial report period.                                |
|                                                                              |
| On January 1, 2002 at 0919, a rescued sea turtle was identified as a green   |
| sea turtle.  This is the 62nd rescue of a live sea turtle at Crystal River   |
| Unit 3 (CR-3) in this biennial period. Notification to the National Marine   |
| Fisheries Service and the Florida Fish and Wildlife Conservation Commission. |
|                                                                              |
|                                                                              |
| The licensee intends to notify the NRC Resident Inspector.                   |
|                                                                              |
| * * *  UPDATE ON 1/05/02 @ 1002 BY RAWLS TO GOULD  * * *                     |
|                                                                              |
| On January 5, 2002, at 0720, a rescued sea turtle was identified as a        |
| Loggerhead Sea Turtle. This is the 63rd rescue of a live sea turtle at       |
| Crystal River Unit 3 (CR3) in this biennial period.  This is reportable as a |
| 4-hour report under 10 CFR 50.72(b)(2)(xi) as this event is related to the   |
| protection of the environment for which a notification to other government   |
| agencies (National Marine Fisheries Service and Florida Fish and Wildlife    |
| Conservation Commission) has been or will be made.                           |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 2 RDO (Decker) was notified.                                             |
|                                                                              |
| * * * UPDATE ON 01/09/02 @ 1107 EST BY ANDY BARNES TAKEN BY MACKINNON * * *  |
|                                                                              |
| On January 9, 2002, at 0838, a rescued sea turtle was identified as a Kemp's |
| Ridley Sea Turtle. This is the 64th rescue of a live turtle at Crystal River |
| Unit 3 (CR-3) in this biennial period. This is reportable as a 4-hour 10 CFR |
| 50.72(b)(2)(xi) as this event is related to the protection of the            |
| environment for which a notification to other government agencies (National  |
| Marine Fisheries Service and Florida Fish and Wildlife Conservation          |
| Commission) has been or will be made.                                        |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 2 (Brian Bonser) was notified.                                           |
|                                                                              |
| * * * UPDATE ON 02/17/02 at 0940 EST BY RICKY RAWLS TO FANGIE JONES * * *    |
|                                                                              |
| "On February 17, 2002 at 0820, a rescued injured sea turtle was identified   |
| as a Kemp's Ridley Sea Turtle. The injury will require transportation to     |
| Clearwater Marine Science Center or Florida Fish and Wildlife Conservation   |
| Refuge. The Injury appears to be from a boat propeller. This is the 65th     |
| rescue of a live sea turtle at Crystal River Unit 3 (CR-3) in this biennial  |
| period. This is Reportable as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi)   |
| as this event is related to the protection of the environment for which a    |
| notification to other government agencies (National Marine Fisheries Service |
| and Florida Fish and Wildlife Conservation Commission) has been or will be   |
| made. This Is an update to event 38602."                                     |
|                                                                              |
| The NRC Resident Inspector will be notified.  R2DO (Stephen Cahill) has been |
| notified.                                                                    |
|                                                                              |
| * * * UPDATE ON 03/01/02 AT 1122 EST BY RICKY RAWLS TO GERRY WAIG * * *      |
|                                                                              |
| "On March 1, 2002 at 0952, a healthy rescued sea turtle was identified as a  |
| Green Sea Turtle. This is the 66th rescue of a live sea turtle at Crystal    |
| River Unit 3 (CR-3) in this biennial period. This is Reportable as a 4-Hour  |
| Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the          |
| protection of the environment for which a notification to other government   |
| agencies (National Marine Fisheries Service and Florida Fish and Wildlife    |
| Conservation Commission) has been or will be made. This is an update to      |
| event 38602."                                                                |
|                                                                              |
| The NRC Resident Inspector was notified. R2DO (Julian) was notified.         |
|                                                                              |
| * * * UPDATE ON 03/07/02 AT 1114 EST BY CHUCK MORRIS TO MIKE NORRIS * * *    |
|                                                                              |
| "On March 7, 2002 at 0835, two healthy sea turtles rescued at CR#3 were      |
| identified as Green Sea Turtles. These are the 67th and 68th live sea turtle |
| rescues at the Crystal River Energy Complex in this biennial period. This is |
| Reportable as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is  |
| related to the protection of the environment for which a notification to     |
| other government agencies (National Marine Fisheries Service and Florida     |
| Fish and Wildlife Conservation Commission) has been or will be made. This is |
| an update to event 38602."                                                   |
|                                                                              |
| The NRC Resident Inspector was notified. R2DO (Henson) was notified.         |
|                                                                              |
| * * * UPDATE ON 04/02/02 at 0408 EST BY RICKY RAWLS TO FANGIE JONES * * *    |
|                                                                              |
| "On April 2, 2002 at 0236, two sea turtles previously rescued at CR#3 intake |
| area were identified by FPC Mariculture staff as Kemp Ridley Sea Turtles.    |
| One of the turtles appears to be in distress and may require transportation  |
| to Clearwater Marine Science Center of Florida Fish and Wildlife             |
| Conservation Refuge. These are the 69th and 70th live sea turtle rescues at  |
| the Crystal River Energy Complex in this biennial period. This is Reportable |
| as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to  |
| the protection of the environment for which a notification to other          |
| government agencies (National Marine Fisheries Service and Florida Fish and  |
| Wildlife Conservation Commission) has been or will be made. This is an       |
| update to event 38602."                                                      |
|                                                                              |
| The NRC Resident Inspector will be notified.  The R2DO (Carolyn Evans) was   |
| notified.                                                                    |
|                                                                              |
| ***** UPDATE AT 1023 EDT ON 05/19/02 FROM PELLERIN TO LEIGH TROCINE *****    |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "On May 19, 2002, at 0916, a sea turtle previously rescued at CR#3 intake    |
| area was identified by FPC Mariculture staff as Green Sea Turtle.  This is   |
| the 71st live sea turtle rescue at the Crystal River Energy Complex in this  |
| biennial period.  This is Reportable as a 4-Hour Report under 10 CFR         |
| 50.72(b)(2)(xi) as this event is related to the protection of the            |
| environment for which a notification to other government agencies (National  |
| Marine Fisheries Service and Florida Fish and Wildlife Conservation          |
| Commission) has been or will be made.  This is an update to event 38602."    |
|                                                                              |
| The licensee plans to notify the National Marine Fisheries Service and       |
| Florida Fish and Wildlife Conservation Commission and the NRC resident       |
| inspector.  The NRC operations officer notified the R2DO (Paul               |
| Fredrickson).                                                                |
|                                                                              |
| * * * UPDATE 1816EDT ON 5/28/02 FROM BERRY FOSTER TO S. SANDIN * * *         |
|                                                                              |
| "On May 28, 2002 at 1700, a sea turtle previously rescued at CR#3 intake     |
| area was identified by FPC Mariculture staff as a Green Sea Turtle. This is  |
| the 72nd live sea turtle rescue at the Crystal River Energy Complex in this  |
| biennial period. The turtle is being transported to the Clearwater Marine    |
| Science Center. This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) |
| (2) (xi) as this event is related to the protection of the environment for   |
| which a notification to other government agencies (National Marine Fisheries |
| Service and Florida Fish and Wildlife Conservation Commission) has been or   |
| will be made. This is an update to event 38602."                             |
|                                                                              |
| The licensee will inform the NRC Resident Inspector.  Notified               |
| R2DO(Landis).                                                                |
|                                                                              |
| * * *UPDATE 1602 EDT ON 5/31/02 FROM BILL BANDHAUER TO MIKE NORRIS* * *      |
|                                                                              |
| "On May 30, 2002 at 1323, a sea turtle previously rescued at CR#3 intake     |
| area was identified by FPC Mariculture staff as a Kemp's Ridley Sea Turtle.  |
| This is the 72nd live sea turtle rescue at the Crystal River Energy Complex  |
| in this biennial period. (Note: The sequential numbering of the live sea     |
| turtle takes has been modified to reflect the actual live sea turtle takes,  |
| On 4/02/02, a live rescue of two turtles was reported, however, one of the   |
| turtles died and was reclassified as a non-causal mortality, which is        |
| non-reportable). This event is Reportable as a 4-Hour Report under 10 CFR    |
| 50.72(b) (2) (xi) as this event is related to the protection of the          |
| environment for which a notification to other government agencies (National  |
| Marine Fisheries Service and Florida Fish and Wildlife Conservation          |
| Commission) has been or will be made. This is an update to event 38602."     |
|                                                                              |
| The NRC Resident Inspector has been notified.  Notified R2DO (Landis).       |
|                                                                              |
| *****UPDATE AT 13:58 EDT ON 7/18/02 FROM SWEENEY TO LAURA*****               |
|                                                                              |
| An offsite notification to the State regarding a green sea turtle that was   |
| rescued from the CR#3 intake area by the FPC Mariculture staff.              |
|                                                                              |
| The NRC resident inspector was notified.  Notified R2DO (C. Payne).          |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39063       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NEW MEXICO RAD CONTROL PROGRAM       |NOTIFICATION DATE:
07/16/2002|
|LICENSEE:  SPECTRA TEK                          |NOTIFICATION TIME: 10:51[EDT]|
|    CITY:  ALBUQUERQUE              REGION:  4  |EVENT DATE:        07/10/2002|
|  COUNTY:                            STATE:  NM |EVENT TIME:             [MDT]|
|LICENSE#:  TA172-21              AGREEMENT:  Y  |LAST UPDATE DATE:  07/17/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |DOUG BROADDUS        NMSS    |
+------------------------------------------------+CHARLIE PAYNE        R2      |
| NRC NOTIFIED BY:  FLOYD                        |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PARTIAL SHIPMENT OF SCANDIUM - 46 LOST IN TRANSIT                            |
|                                                                              |
| A FedEx shipment from the Spectra Tek in Albuquerque to Protechnics in       |
| Lafayette, LA.  of six packages of scandium -  46 at 40 millicuries each     |
| arrived at its destination one package short on 7/10/02.   They are tracing  |
| the shipment and determined it was last scanned on 7/9/02 in Memphis, TN.    |
|                                                                              |
| **** Update at 1152 ET on 07/17/02 by Bill Floyd taken by MacKinnon ****     |
|                                                                              |
| The missing package containing the scandium-46 was found on the FedEx        |
| loading dock in Lafayette , LA. The package will be delivered to             |
| Protechnics.  R4DO (Linda Howell) & NMSS EO (Fred Brown) notified.           |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39064       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TENNESSEE DIV OF RAD HEALTH          |NOTIFICATION DATE: 07/16/2002|
|LICENSEE:  DURATEK RADWASTE PROCESSING, INC.    |NOTIFICATION TIME:
12:05[EDT]|
|    CITY:  OAK RIDGE                REGION:  2  |EVENT DATE:        07/12/2002|
|  COUNTY:                            STATE:  TN |EVENT TIME:        08:30[EDT]|
|LICENSE#:  R-73008               AGREEMENT:  Y  |LAST UPDATE DATE:  07/16/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHARLIE PAYNE        R2      |
|                                                |JAMES LINVILLE       R1      |
+------------------------------------------------+FRED BROWN           NMSS    |
| NRC NOTIFIED BY:  BILLY FREEMAN                |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING EQUIPMENT FAILURE OF SHIPPING
CONTAINER     |
|                                                                              |
| "Event Report ID No.:  TN-02-094                                             |
|                                                                              |
| "License No.:  R-73008                                                       |
|                                                                              |
| "Licensee:  Duratek Radwaste Processing, Inc.                                |
|                                                                              |
| "Event date and time:  July 12, 2002, 0830EDT                                |
|                                                                              |
| "Event location:  Oak Ridge, Tennessee                                       |
|                                                                              |
| "Event type:  Equipment failure                                              |
|                                                                              |
| "Notifications:  USNRC Region II                                             |
|                                                                              |
| "Event description:  Duratek Radwaste Processing, Inc., a Tennessee          |
| licensee, called the Knoxville Field Office Manager to report that a sealand |
| container of metals from Calvert Cliffs Nuclear Power Plant was received at  |
| the Duratek facility on July 12, 2002.  During performance of the receipt    |
| survey/inspection, metal from the interior was observed protruding           |
| approximately 1/2" from a penetration in the side of the container.  No      |
| detectable contamination was found on the accessible item or on the adjacent |
| sealed surfaces. The penetration in the container wall was covered to permit |
| undisturbed storage pending further investigation.                           |
|                                                                              |
| "Media attention:  None"                                                     |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39065       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NC DIV OF RADIATION PROTECTION       |NOTIFICATION DATE: 07/16/2002|
|LICENSEE:  AMERISTEEL CORPORATION               |NOTIFICATION TIME: 14:08[EDT]|
|    CITY:  CHARLOTTE                REGION:  2  |EVENT DATE:        07/11/2002|
|  COUNTY:                            STATE:  NC |EVENT TIME:             [EDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  07/16/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHARLIE PAYNE        R2      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  GRANT T. MILLS               |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING Cs-137 SOURCE FOUND IN SCRAP STEEL       
  |
|                                                                              |
| "SUBJECT: North Carolina Incident No. 02-21                                  |
|                                                                              |
| "On July 11, 2002 the North Carolina Radiation Protection Section was        |
| notified by AmeriSteel Corp., Charlotte Steel Mill Division that they had    |
| discovered a radioactive source in their scrap stream. The source has been   |
| isolated and secured by AmeriSteel personnel.  Exposure rates of 120         |
| microR/hr @ 3" have been reported by AmeriSteel personnel. Using an          |
| Exploranium GR-130 AmeriSteel personnel have identified the source as        |
| Cesium-137. The North Carolina Radiation Protection Section is continuing to |
| gather information and work with the facility to provide appropriate         |
| action."                                                                     |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39069       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HADDAM NECK              REGION:  1  |NOTIFICATION DATE: 07/18/2002|
|    UNIT:  [1] [] []                 STATE:  CT |NOTIFICATION TIME: 11:35[EDT]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        07/18/2002|
+------------------------------------------------+EVENT TIME:        10:19[EDT]|
| NRC NOTIFIED BY:  REID                         |LAST UPDATE DATE:  07/18/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES LINVILLE       R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION FOR OIL SPILL >10 GALLONS                               |
|                                                                              |
|                                                                              |
| Licensee notified the National Response Center and State Department of       |
| Environmental Protection of an oil spill >10 gallons.  Hydraulic oil spilled |
| from a fork lift onto the ground inside plant property and cleanup is in     |
| progress.                                                                    |
|                                                                              |
| Site has no resident inspector.                                              |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39070       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OCONEE                   REGION:  2  |NOTIFICATION DATE: 07/18/2002|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 18:43[EDT]|
|   RXTYPE: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-L|EVENT DATE:        07/18/2002|
+------------------------------------------------+EVENT TIME:             [EDT]|
| NRC NOTIFIED BY:  STEVE NEWMAN                 |LAST UPDATE DATE:  07/18/2002|
|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHARLIE PAYNE        R2      |
|10 CFR SECTION:                                 |                             |
|AINA 50.72(b)(3)(v)(A)   POT UNABLE TO SAFE SD  |                             |
|AINB 50.72(b)(3)(v)(B)   POT RHR INOP           |                             |
|AINC 50.72(b)(3)(v)(C)   POT UNCNTRL RAD REL    |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ATMOSHERIC STEAM DUMP VALVE PRESSURE LOCKING CONCERN                         |
|                                                                              |
| "At approximately 1600 hours on July 18, 2002, an engineering evaluation     |
| concluded that under certain conditions 1MS-156, a manually operated main    |
| steam atmospheric dump valve (ADV), could have been susceptible to Pressure  |
| Locking which could have prevented the opening of the valve during a         |
| postulated event. This notification involves a single unit 1 ADV (1MS-156)   |
| on 1 of 2 steam flow paths. Due to a dissimilar valve design, this condition |
| does not affect either the unit 2 or unit 3 ADVs                             |
|                                                                              |
| "Research into the condition has determined that 1MS-156 was potentially     |
| susceptible to pressure locking during the time of reactor operation, from   |
| initial valve installation in November 1997, to when this condition was      |
| rectified on July 10, 2002 (by the installation of a pressure relief device  |
| on the valve bonnet) . Since the cause of the pressure locking has been      |
| fixed, there is no current operability concern.                              |
|                                                                              |
| "The ADVs are credited for opening for decay heat removal and cooling down   |
| the Reactor Coolant System to reduce pressure. In several event scenarios    |
| involving postulated Steam Generator tube leaks, this is desirable in order  |
| to minimize offsite dose releases. Failure of 1MS-156 during such an event   |
| could increase the time required to achieve cold shutdown (Mode 5) and the   |
| postulated off-site doses associated with the accident analysis. However,    |
| the analyses for such events (for example, the UFSAR Chapter 15 accident     |
| analysis for SG tube rupture) do not assume any failures of the ADVs.        |
|                                                                              |
| "This is a historical condition reportable under 10 CFR 50.72(b) (3) (v) .   |
| This regulation requires that an 8-hour ENS report be made of any event or   |
| condition that at the time of discovery could have prevented the fulfillment |
| of the safety function of structures or systems that are needed to (A) .     |
| Shut down the reactor and maintain it in a safe shutdown condition; (B)      |
| Remove residual heat; (C) . Control the release of radioactive material; or  |
| (D) - Mitigate the consequences of an accident.                              |
|                                                                              |
| "Investigation into the cause of this condition is ongoing."                 |
|                                                                              |
| The NRC Resident Inspector has been notified.                                |
+------------------------------------------------------------------------------+
.