Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for February 1, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           01/31/2002 - 02/01/2002

                              ** EVENT NUMBERS **

38663  38664  38665  

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38663       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 01/31/2002|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 13:30[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        01/30/2002|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        12:00[CST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  01/31/2002|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |RONALD GARDNER       R3      |
|  DOCKET:  0707001                              |DOUG BROADDUS        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  M. C. PITTMAN                |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LEGACY ISSUE                                                                 |
|                                                                              |
| NRC BULLETIN 91-01 24 HOUR NOTIFICATION                                      |
|                                                                              |
| "AT 1313 CST, on 1-30-02 the Plant Shift Superintendent (PSS) was notified   |
| of uncharacterized legacy process equipment which was not stored in          |
| accordance with an approved Nuclear Criticality Safety Approval (NCSA).  The |
| mass of fissile material was less than a safe mass and at an assay of less   |
| than 2.0 Wt. %.  This is in violation of the NCS program requirements of     |
| SAR, Section 5.2 which requires fissile material operations to be controlled |
| by approved NCSA's.                                                          |
|                                                                              |
| "The PSS determined that this event is a 24 Hour Event Report due to the     |
| failure to maintain double contingency controls.                             |
|                                                                              |
| SAFETY SIGNIFICANCE  OF EVENTS:                                              |
|                                                                              |
| "This material is in a stable condition and double contingency has been      |
| established using approved procedures.  Once the material was characterized, |
| it was determined that proper spacing had been maintained.                   |
|                                                                              |
| POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO(S) OF HOW            |
| CRITICALITY COULD OCCUR):                                                    |
|                                                                              |
| "In order for criticality to be possible more than a critical mass would     |
| need to be accumulated in an unsafe geometry.  The storage containers are    |
| safe by geometry and the fissile material is less than a safe mass.          |
| Therefore, it is not possible for this barrier material to result in a       |
| criticality accident.                                                        |
|                                                                              |
| CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION,
ETC.):     |
| "Mass                                                                        |
|                                                                              |
| ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE
PROCESS     |
| LIMIT AND % WORST CASE CRITICAL MASS):                                       |
|                                                                              |
| "Less than 10 pounds at an enrichment of less than 2.0 Wt. %                 |
|                                                                              |
| NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND
DESCRIPTION   |
| OF THE FAILURES OR DEFICIENCIES:                                             |
|                                                                              |
| "Since no NCS controls were applied to the material, double contingency      |
| cannot be demonstrated.                                                      |
|                                                                              |
| CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEMS AND WHEN EACH WAS
IMPLEMENTED:  |
|                                                                              |
| "The material is controlled in accordance with procedure CP-2-TS-TS2030.     |
| The material has been characterized."                                        |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38664       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  MISSISSIPPI DIV OF RAD HEALTH        |NOTIFICATION DATE: 01/31/2002|
|LICENSEE:  H&H X-RAY SERVICES                   |NOTIFICATION TIME: 16:06[EST]|
|    CITY:                           REGION:  2  |EVENT DATE:        10/01/2001|
|  COUNTY:                            STATE:  MS |EVENT TIME:        12:00[CST]|
|LICENSE#:  MS622-01              AGREEMENT:  Y  |LAST UPDATE DATE:  01/31/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MIKE ERNSTES         R2      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  B. J. SMITH                  |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OVEREXPOSURE                                                                 |
|                                                                              |
| The film badges of two radiographers working for H& H X-Ray Services were    |
| processed for the month of October, 2001.  The readings of the film badges   |
| for the month of October were 7909 mrem and 3825 mrem.  H & H X-Ray Services |
| individuals were using a 68 curie (Iridium-192) radiography camera  in       |
| Monroe, LA. The State of Mississippi Division of Radiation Health is         |
| following up on this report.                                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38665       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WOLF CREEK               REGION:  4  |NOTIFICATION DATE: 01/31/2002|
|    UNIT:  [1] [] []                 STATE:  KS |NOTIFICATION TIME: 17:56[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        01/31/2002|
+------------------------------------------------+EVENT TIME:        13:45[CST]|
| NRC NOTIFIED BY:  S. FERGUSON                  |LAST UPDATE DATE:  01/31/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHARLES MARSCHALL    R4      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF 6 EMERGENCY SIRENS DUE TO ICE STORMS                                 |
|                                                                              |
| AT 1345 it was determined that six of their eleven emergency plant sirens    |
| were not operational.  An ice storm caused the loss of power to the sirens.  |
| The county sheriffs office was contacted and in the event of an actual       |
| emergency they will contact personnel in these areas directly (route         |
| alerting).  The remaining five sirens will alert a majority of the           |
| population in the effective ten mile zone.  The total ten mile zone is       |
| approx. 6099 persons.                                                        |
|                                                                              |
| The remote telemetry system used to identify siren failures did not function |
| correctly.  We determined that at least one siren was unavailable and this   |
| information was unavailable from the normal monitoring method.  A backup     |
| method was used to determine the extent of the problem.                      |
|                                                                              |
| A news statement was issued to the public at approximately 1600 hours,       |
| 01/31/02, discusses the loss of the six emergency sirens.                    |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021