Event Notification Report for January 10, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           01/09/2001 - 01/10/2001

                              ** EVENT NUMBERS **

37657  37658  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37657       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 01/09/2001|
|    UNIT:  [] [] [3]                 STATE:  IL |NOTIFICATION TIME: 08:13[EST]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        01/09/2001|
+------------------------------------------------+EVENT TIME:        04:01[CST]|
| NRC NOTIFIED BY:  RUNION                       |LAST UPDATE DATE:  01/09/2001|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN JACOBSON        R3      |
|10 CFR SECTION:                                 |                             |
|AINC 50.72(b)(2)(iii)(C) POT UNCNTRL RAD REL    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ISOLATION CONDENSER STEAM CONDENSATE HIGH FLOW SWITCHES OUT OF CALIBRATION   |
|                                                                              |
| "During performance of DIS 1300-07, Isolation Condenser Steam Condensate     |
| High Flow Switch Calibration, DP switch 3-1349A as found trip setpoint was   |
| outside of T.S. limits.  The as found value was -17.5 in WC and the T.S.     |
| limit is </= to 14.8 in WC.  Later in the same surveillance, DP switch       |
| 3-1349B as found trip setpoint was outside of T.S.  limit is </= 14.8 in WC. |
| These are the Div 1 and Div 2 Isolation Condenser Condensate High Flow       |
| isolation instruments.  With both these switches inop, the Isolation         |
| Condenser would not have isolated at the appropriate time on a valid high    |
| condensate flow signal.  The Isolation Condenser was already isolated when   |
| the out of tolerance switches were discovered and the switches were          |
| calibrated satisfactorily prior to unisolating the Isolation Condenser."     |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37658       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PERRY                    REGION:  3  |NOTIFICATION DATE: 01/09/2001|
|    UNIT:  [1] [] []                 STATE:  OH |NOTIFICATION TIME: 13:08[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        01/09/2001|
+------------------------------------------------+EVENT TIME:        12:20[EST]|
| NRC NOTIFIED BY:  ROBERT KIDDER                |LAST UPDATE DATE:  01/09/2001|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN JACOBSON        R3      |
|10 CFR SECTION:                                 |ED GOODWIN           NRR     |
|KSNM 70.52(a)            LOSS OF SNM/CRIT       |FRITZ STURZ          NMSS    |
|KFIS 70.52(b)            LOSS OF SNM/FISSILE    |JOSEPH GIITTER       IRO     |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |ROBERT SKELTON       IAT     |
|                                                |JOHN DAVIDSON        IAT     |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       87       Power Operation  |87       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| NEUTRON MONITORING DETECTOR MISSING FROM SHIPMENT                            |
|                                                                              |
| The licensee reported that one local power range monitor (LPRM) detector was |
| missing out of a shipment from GE Reuter-Stokes in Twinsburg, OH. The        |
| missing detector contains 0.00027g of U-235 (0.00121g total U) in the form   |
| of solid uranium oxide. The licensee has contacted the vendor to determine   |
| whether an error occurred in preparation of the shipping papers. The NRC     |
| resident inspector will be informed of this event by the licensee.           |
|                                                                              |
| * * * UPDATE 1529 FROM KIDDER TAKEN BY STRANSKY * * *                        |
|                                                                              |
| At 1355, the licensee was informed that the missing LPRM detector is         |
| currently located at the GE Reuter-Stokes facility and had not been shipped. |
| The NRC resident inspector has been informed of this update. Notified R3DO   |
| (Jacobson).                                                                  |
+------------------------------------------------------------------------------+