Event Notification Report for January 2, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           12/29/2000 - 01/02/2001

                              ** EVENT NUMBERS **

37638  37639  37640  37641  
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37638       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE                REGION:  1  |NOTIFICATION DATE: 12/29/2000|
|    UNIT:  [] [] [3]                 STATE:  CT |NOTIFICATION TIME: 22:03[EST]|
|   RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP           |EVENT DATE:        12/29/2000|
+------------------------------------------------+EVENT TIME:        21:31[EST]|
| NRC NOTIFIED BY:  JOSEPH FRANKS                |LAST UPDATE DATE:  12/29/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LAWRENCE DOERFLEIN   R1      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          Y       96       Power Operation  |96       Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EMERGENCY NOTIFICATION SPEAKERS INOPERABLE                                   |
|                                                                              |
| The licensee reported that the emergency notification speakers in New        |
| London, CT could not be operated from either the primary nor the secondary   |
| locations. The municipality had planned to use the speakers to provide       |
| information regarding an impending winter storm. The problem was traced to   |
| faulty wiring and has been repaired. The NRC resident inspector has been     |
| informed of this notification by the licensee.                               |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37639       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CT RESOURCE RECOVERY AUTHORITY       |NOTIFICATION DATE: 12/30/2000|
|LICENSEE:  CT RESOURCE RECOVERY AUTHORITY       |NOTIFICATION TIME: 01:49[EST]|
|    CITY:  HARTFORD                 REGION:  1  |EVENT DATE:        12/29/2000|
|  COUNTY:                            STATE:  CT |EVENT TIME:        19:00[EST]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  12/30/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LAWRENCE DOERFLEIN   R1      |
|                                                |SUSAN SHANKMAN       NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DOMINICK MARQUEZ             |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EXPLOSION AT WASTE PROCESSING FACILITY INVOLVING LICENSED GAUGE              |
|                                                                              |
| AT APPROXIMATELY 1900EST ON 12/29/00 AN EXPLOSION OCCURRED IN THE PRIMARY    |
| SHREDDER WHICH IS ATTACHED TO THE BAGHOUSE AT THE CONNECTICUT RESOURCE       |
| RECOVERY AUTHORITY (CRRA), MID-CONNECTICUT PROJECT WASTE PROCESSING          |
| FACILITY.  THE BAGHOUSE CONTAINS A LICENSED NUCLEAR GAUGE CONTAINING A       |
| Cs-137 SOURCE USED TO MONITOR AIRBORNE PARTICLES TO ALERT OPERATORS OF TRASH |
| (DUST) BUILDUP.  THE LICENSEE CONFIRMED USING A GEIGER COUNTER THAT THE      |
| SOURCE AND HOUSING WERE NOT DAMAGED.  THE LICENSEE NOTIFIED THE CT           |
| DEPARTMENT OF ENVIRONMENTAL PROTECTION.  THE LICENSEE IS MAKING THIS         |
| NOTIFICATION AS REQUIRED BY CHAPTER 7, NUCLEAR LEVEL DETECTOR, OF THE        |
| METROPOLITAN DISTRICT COMMISSION (MDC) WASTE PROCESS SAFETY MANUAL.          |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37640       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 12/30/2000|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 17:05[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        12/30/2000|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        12:20[EST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  12/30/2000|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |PATRICK HILAND       R3      |
|  DOCKET:  0707002                              |SUSAN SHANKMAN       NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  RON CRABTREE                 |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NCFR                     NON CFR REPORT REQMNT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR REPORT REGARDING ACTIVATION OF SMOKE HEADS                           |
|                                                                              |
| "At approximately 1220 hours on 12/30/00, a process operator was conducting  |
| weekly valve status checks on the cell floor above the extended range        |
| products station when three CADP smoke heads alarmed. The operator did see a |
| visible haze and smell HF as he immediately left the area. 'See and flee'    |
| emergency procedures were immediately implemented. The affected ERP          |
| withdrawal station was in an applicable TSR mode (withdrawal) at the time of |
| the alarm. Results of all surveys performed for airborne HF and radiation    |
| were less than MDA. At 1324 hours an 'all clear' was granted on emergency    |
| response. PORTS is reporting this alarm as a valid actuation of a 'Q' safety |
| system, which is the CADP smokehead."                                        |
|                                                                              |
| The NRC resident inspector has been informed of this event.                  |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37641       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAN ONOFRE               REGION:  4  |NOTIFICATION DATE: 12/31/2000|
|    UNIT:  [] [2] []                 STATE:  CA |NOTIFICATION TIME: 06:33[EST]|
|   RXTYPE: [1] W-3-LP,[2] CE,[3] CE             |EVENT DATE:        12/31/2000|
+------------------------------------------------+EVENT TIME:        01:30[PST]|
| NRC NOTIFIED BY:  CLAY WILLIAMS                |LAST UPDATE DATE:  12/31/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHARLES MARSCHALL    R4      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL ACTUATION OF CONTAINMENT EMERGENCY COOLER UNITS                       |
|                                                                              |
| "On December 31, 2000, at about 0130 PST, containment normal cooler unit     |
| ME201 tripped on indicated high temperature (cause under investigation).     |
| During preparations to start the opposite train containment normal cooler    |
| Unit (ME202), in response to the expected slow increase in containment       |
| temperature, Operators manually started the 4 containment emergency cooler   |
| units (an engineered safety features system).  At about 0220 PST Operators   |
| started normal cooler unit ME202 and stopped the 4 ECUs.  Consistent with    |
| the guidance provided in NUREG-1022, Rev 1, SCE is reporting this occurrence |
| in accordance with 10CFR50.72(b)(2)(ii) for a manual start of an ESF         |
| component.                                                                   |
|                                                                              |
| "At the time of this occurrence Unit 2 was operating at about 100% power,    |
| Unit 3  was operating at about 85% power; and Unit 1 remains permanently     |
| defueled.  SCE will notify the NRC resident inspectors about this occurrence |
| and will provide them a copy of this report."                                |
+------------------------------------------------------------------------------+
.