Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for October 1, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/30/1999 - 10/01/1999

                              ** EVENT NUMBERS **

35790  36219  36244  36245  36246  36247  36248  36249  36250  

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35790       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 06/03/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 14:44[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        06/02/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        16:30[CDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  09/30/1999|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |DAVID HILLS          R3      |
|  DOCKET:  0707001                              |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  THOMAS WHITE                 |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|OCBA 76.120(c)(2)(i)     ACCID MT EQUIP FAILS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THREE SPRINKLER SYSTEMS DECLARED INOPERABLE DUE TO CORRODED HEADS (24-hour   |
| report)                                                                      |
|                                                                              |
| The following text is a portion of a facsimile received from Paducah:        |
|                                                                              |
| "On 06/02/99 at 1630 CDT, the Plant Shift Superintendent (PSS) was notified  |
| that numerous sprinkler heads were corroded, affecting 16 sprinkler systems  |
| in C-337 and one system in C-333, such that the ability of the sprinklers to |
| flow sufficient water was called into question.  Subsequently, these         |
| sprinkler systems were declared inoperable, and TSR-required actions         |
| establishing roving fire patrols were initiated.  This deficiency was        |
| detected during scheduled system inspections conducted by Fire Protection    |
| personnel.  Currently, functionality of the sprinkler heads has not been     |
| fully evaluated by Fire Protection personnel, and the remaining cascade      |
| buildings are currently being inspected, and if necessary, this report will  |
| be updated to identify any additional areas.                                 |
|                                                                              |
| "It has been determined that this event is reportable under                  |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to     |
| function as designed."                                                       |
|                                                                              |
| The NRC resident inspector has been notified of this event.                  |
|                                                                              |
|                                                                              |
| * * * UPDATE AT 1022 EDT ON 06/04/99 FROM CAGE TO TROCINE * * *              |
|                                                                              |
| "Two sprinkler heads on system D-1 in C-337 and two sprinkler heads on       |
| system 27 in C-335 were identified to also be corroded.  These were          |
| identified to the PSS on 06/03/99 at 1600 CDT and 1601 CDT, respectively,    |
| and determined to require an update to this report by the PSS.               |
|                                                                              |
| "It has been determined that this event is reportable under                  |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to     |
| function as designed."                                                       |
|                                                                              |
| Paducah personnel notified the NRC resident inspector of this update.  The   |
| NRC operations officer notified the R3DO (Hills) and NMSS EO (Combs).        |
|                                                                              |
| * * * UPDATE AT 2152 EDT ON 06/17/99 FROM WALKER TO POERTNER * * *           |
|                                                                              |
| "Three sprinkler heads on system C-15 and five sprinkler heads on system B-8 |
| in C-333 were identified to also be corroded.  The PSS was notified of this  |
| condition at 1300 CDT on 06/17/99 and determined that an update to this      |
| report was required."                                                        |
|                                                                              |
| "It has been determined that this event is reportable under                  |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to     |
| function as designed."                                                       |
|                                                                              |
| Paducah personnel notified the NRC resident inspector of this update.  The   |
| NRC operations officer notified the R3DO (Madera).                           |
|                                                                              |
| * * * UPDATE 1440 EDT 6/18/1999 FROM UNDERWOOD TAKEN BY STRANSKY * * *       |
|                                                                              |
| "Two sprinkler heads on system C-15 and one sprinkler head on system B-8 in  |
| C-333 were identified to have corrosion.  The PSS was notified of this       |
| condition at 1350 CDT on 06/18/99.  The area of the fire patrol for system   |
| C-15 was expanded to include the two heads identified as corroded.  The one  |
| head on system B-8 was in the area already being patrolled.  The PSS         |
| determined that an update to this report was required."                      |
|                                                                              |
| The NRC resident inspector has been informed of this update.  Notified R3DO  |
| (Madera).                                                                    |
|                                                                              |
| * * * UPDATE 1315 EDT 6/25/1999 FROM WALKER TAKEN BY STRANSKY * * *          |
|                                                                              |
| "Two sprinkler heads on system D-8 and three sprinkler heads on system D-7   |
| in C-337 were identified to have corrosion.  The PSS was notified of the     |
| condition on system D-8 at 0125 CDT on 06/25/99 and at 1019 CDT on 06/25/99  |
| for system D-7.  Both systems were immediately declared inoperable and LCO   |
| fire patrol actions were implemented.  It was determined that an update to   |
| this report was required."                                                   |
|                                                                              |
| The NRC resident inspector has been informed of this update.  Notified R3DO  |
| (Jordan).                                                                    |
|                                                                              |
| * * * UPDATE 2119 EDT 7/30/1999 FROM CAGE TAKEN BY STRANSKY * * *            |
|                                                                              |
| "Five sprinkler heads and one sprinkler piping tee on C-337 system D-7 were  |
| identified to have corrosion. The PSS was notified of these corroded system  |
| parts and declared the system inoperable at 0931 CDT on 07/30/99.  LCO       |
| required fire patrols of the affected area were initiated.  The PSS          |
| determined that an update to this event report was required."                |
|                                                                              |
| The NRC resident inspector has been informed of this update.  Notified R3DO  |
| (Wright).                                                                    |
|                                                                              |
| * * * UPDATE 1655 EDT 7/31/1999 FROM WHITE TAKEN BY STRANSKY * * *           |
|                                                                              |
| "Two sprinkler heads on C-337 System D-1 were identified to have corrosion.  |
| The PSS was notified of these corroded system parts and declared the system  |
| inoperable at 1155 CDT on 7/31/99.  LCO required fire patrols of the         |
| affected area were initiated.  The PSS determined that an update to this     |
| report was required."                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this update. Notified R3DO   |
| (Wright).                                                                    |
|                                                                              |
| * * * UPDATE 1546 EDT 8/10/1999 FROM WHITE TAKEN BY STRANSKY * * *           |
|                                                                              |
| "Two sprinkler heads on C-337 system C-15 were identified to have corrosion. |
| The PSS was notified of these corroded system parts and declared the system  |
| inoperable at 1130 CDT on 8/10/99.  LCO required fire patrols of the         |
| affected area were initiated.  The PSS determined that an update to this     |
| report was required."                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this update. Notified R3DO   |
| (Burgess).                                                                   |
|                                                                              |
| * * * UPDATE AT 1154 EDT 8/22/99 FROM WALKER TO POERTNER * * *               |
|                                                                              |
| Four adjacent sprinkler heads on C-333 System B-1 were identified to have    |
| corrosion.  The PSS was notified of the corroded system parts and declared   |
| the system inoperable at 0918 CDT on 8/22/99.  LCO required fire patrols     |
| were initiated.  The PSS determined that an update to this report was        |
| required.                                                                    |
|                                                                              |
| It has been determined that this event is reportable under 10CFR76.120(c)(2) |
| as an event in which equipment is disabled or fails to function as           |
| designed.                                                                    |
|                                                                              |
| The NRC resident inspector will be notified.                                 |
|                                                                              |
| The NRC operations officer notified the R3DO (Clayton).                      |
|                                                                              |
| * * * UPDATE 2015 EDT ON 8/28/99 FROM W.F. GAGE TO S. SANDIN * * *           |
|                                                                              |
| The following information was provided as an update to this report:          |
|                                                                              |
| "Two adjacent sprinkler heads on C-337 System D-11 were identified to have   |
| corrosion.  The PSS was notified of these corroded system parts and declared |
| the system inoperable at 1420 [CDT] on 8/28/99.   LCO required fire patrols  |
| of the affected area were initiated. The PSS determined that an update to    |
| this report was required."                                                   |
|                                                                              |
| Paducah personnel informed the NRC resident inspector.  The NRC operations   |
| officer notified the R3DO (Leach) and NMSS EO (Piccone).                     |
|                                                                              |
| * * * UPDATE 2037 EDT ON 8/29/99 FROM KEVIN BEASLEY TO S. SANDIN * * *       |
|                                                                              |
| The following information was provided as an update to this report:          |
|                                                                              |
| "Two adjacent sprinkler heads on C-337 System D-15 were identified to have   |
| corrosion and the PSS declared the system inoperable at 0925 [CDT] on        |
| 8/29/99.  Also two adjacent heads on C-337 System D-10 were identified to    |
| have corrosion and the PSS declared the system inoperable at 1450.   LCO     |
| required fire patrols for both of the affected areas were initiated in the   |
| time frame required by TSR.  The PSS determined that an update to this       |
| report was required."                                                        |
|                                                                              |
| Paducah personnel informed the NRC resident inspector.  The NRC operations   |
| officer notified the R3DO (Leach) and NMSS EO (Piccone).                     |
|                                                                              |
| * * * UPDATE AT 0930 EDT ON 9/1/99  BY ERIC WALKER TO FANGIE JONES * * *     |
|                                                                              |
| Add two adjacent sprinkler heads on C-337 D-14.  Paducah personnel informed  |
| the NRC Resident Inspector.  The NRC operations officer notified the R3DO    |
| (David Hills) and NMSS (Robert Pierson).                                     |
|                                                                              |
| * * * UPDATE AT 1133 EDT ON 9/8/99  BY TOM WHITE TO FANGIE JONES * * *       |
|                                                                              |
| Add two adjacent sprinkler heads on C-331 System 26, system declared         |
| inoperable at 2155 CDT on 9/7/99. An LCO required fire patrol for the        |
| affected area was initiated in the time frame required by the TSR.  Paducah  |
| personnel informed the NRC Resident Inspector.  The NRC operations officer   |
| notified the R3DO (Monte Phillips) and NMSS (Josie Piccone).                 |
|                                                                              |
| * * * UPDATE AT 0948 ON 9/30/99 BY ERIC WALKER TO DOUG WEAVER * * *          |
|                                                                              |
| Add two adjacent sprinkler heads on C-333  System B-15 were identified to    |
| have corrosion and the PSS declared the system inoperable at 0815 on         |
| 9/30/99.  An LCO required fire patrol for the affected area was initiated in |
| the time frame required by the TSR.  The PSS determined that an update to    |
| this report was required.                                                    |
| Paducah personnel informed the NRC resident inspector.   The NRC operations  |
| officer notified the R3DO (Vegel) and NMSS (Cool).                           |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36219       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 09/23/1999|
|    UNIT:  [1] [2] [3]               STATE:  AL |NOTIFICATION TIME: 18:50[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        09/23/1999|
+------------------------------------------------+EVENT TIME:        16:55[CDT]|
| NRC NOTIFIED BY:  RAY SWAFFORD                 |LAST UPDATE DATE:  09/30/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY REPORT                                                              |
|                                                                              |
| Discovery of compromise of safeguards information, compensatory measures not |
| fully implemented.  The licensee notified the NRC Resident Inspector.        |
|                                                                              |
| Refer to the HOO Log for additional details.                                 |
|                                                                              |
| * * * UPDATE AT 1624 ON  09/30/99 BY RON DAVENPORT & RON LeCROY TO JOLLIFFE  |
| * * *                                                                        |
|                                                                              |
| The licensee has determined that the compromise of safeguards information    |
| which occurred was not significant.  Based on the safeguards event reporting |
| guidance in NRC Regulatory Guide 5.62 and NRC Generic Letter 91-03, the      |
| licensee desires to retract this event.  The licensee is downgrading this    |
| event to a loggable even.                                                    |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The NRC Operations        |
| Officer notified the R2DO Rudolph Bernhard.                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36244       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HOPE CREEK               REGION:  1  |NOTIFICATION DATE: 09/29/1999|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 22:22[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        09/29/1999|
+------------------------------------------------+EVENT TIME:        21:33[EDT]|
| NRC NOTIFIED BY:  KEN BRESLIN                  |LAST UPDATE DATE:  09/30/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNU                   |DAVID SILK           R1      |
|10 CFR SECTION:                                 |LEDYARD (TAD) MARSH  NRR     |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |JOSEPH GIITTER       IRO     |
|                                                |STINEDURF            FEMA    |
|                                                |FRANK CONGEL         IRO     |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO A FREON LEAK FROM A CONTROL ROOM CHILLER INTO  |
| THE AUXILIARY BUILDING                                                       |
|                                                                              |
| The licensee declared the unusual event at 2133 on 09/29/99 due to a release |
| of toxic gas (a Freon leak) deemed to be detrimental to safe operation of    |
| the plant.  No radiological release is in progress.  The 33' wind direction  |
| is from 146� at 17.9 miles per hour.  There were no protective actions       |
| recommended.                                                                 |
|                                                                              |
| At 2117 hours on 09/29/99, the 'B' control room ventilation train chiller    |
| tripped resulting in an automatic start of the 'A' control room ventilation  |
| train.  The trip was the direct result of a major freon leak dispersing into |
| the auxiliary building.  All non-essential personnel were evacuated from the |
| auxiliary building.  An Unusual Event was declared at 2133 hours on 09/29/99 |
| in accordance with Emergency Classification Guidance Section 9.4.1.B,        |
| release of toxic gas deemed detrimental to safe operation of the plant.  No  |
| personnel injuries have occurred, and all access to the auxiliary building   |
| is being controlled until follow-up actions are complete.                    |
|                                                                              |
| The 'A' control room vent train is currently in service.  There is no        |
| indication of any freon in the control room, and the control room was not    |
| placed on recirculation.                                                     |
|                                                                              |
| The licensee plans to terminate the Unusual Event when the freon leak is     |
| isolated and when air levels in the auxiliary building are restored to       |
| normal.                                                                      |
|                                                                              |
| The licensee stated that the emergency response data system (ERDS) has not   |
| been activated because ERDS is down for the performance of Y2K upgrades.     |
|                                                                              |
| The licensee notified the NRC resident inspector, the states of Delaware and |
| New Jersey, and the Lower Alloways Creek Township.                           |
|                                                                              |
| ******************** UPDATE AT 0204 ON 09/30/99 FROM KEN BRESLIN TO DOUG     |
| WEAVER ********************                                                  |
|                                                                              |
| The leak was terminated because the full freon charge in the chiller         |
| dispersed (2,200 pounds), and the atmosphere in the auxiliary building has   |
| been restored to normal.  As a result, the licensee terminated the Unusual   |
| Event at 0158 hours on 09/30/99.                                             |
|                                                                              |
| The licensee notified the NRC resident inspector, the states of Delaware and |
| New Jersey, and the Lower Alloways Creek Township.  The NRC operations       |
| officer notified the R1DO (Silk), NRR EO (Marsh), IRO (Giitter), and FEMA    |
| (Caldwell)                                                                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36245       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HADDAM NECK              REGION:  1  |NOTIFICATION DATE: 09/30/1999|
|    UNIT:  [1] [] []                 STATE:  CT |NOTIFICATION TIME: 10:32[EDT]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        09/30/1999|
+------------------------------------------------+EVENT TIME:        09:30[EDT]|
| NRC NOTIFIED BY:  JON OWER                     |LAST UPDATE DATE:  09/30/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAVID SILK           R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION - SMALL OIL SPILL                                       |
|                                                                              |
| APPROXIMATELY ONE GALLON OF HYDRAULIC OIL WAS SPILLED FROM A BARGE INTO THE  |
| CONNECTICUT RIVER AT THE HADDAM NECK SITE.  THE LICENSEE NOTIFIED THE        |
| CONNECTICUT DEPARTMENT OF ENVIRONMENTAL PROTECTION,  THE NATIONAL RESPONSE   |
| CENTER, THE U.S COAST GUARD AND THE TOWN OF EAST HAMPTON.                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36246       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 09/30/1999|
|    UNIT:  [1] [] []                 STATE:  TX |NOTIFICATION TIME: 17:36[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/30/1999|
+------------------------------------------------+EVENT TIME:        15:45[CDT]|
| NRC NOTIFIED BY:  H. ALLEGEYER                 |LAST UPDATE DATE:  09/30/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JEFF SHACKELFORD     R4      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY REPORT                                                              |
|                                                                              |
| Unescorted access granted inappropriately, immediate compensatory measures   |
| taken upon discovery.  The licensee intends to notify the NRC Resident       |
| Inspector.                                                                   |
|                                                                              |
| Refer to HOO Log for additional details.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36247       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 09/30/1999|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 17:54[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        09/30/1999|
+------------------------------------------------+EVENT TIME:        14:10[EDT]|
| NRC NOTIFIED BY:  PHIL ROSE                    |LAST UPDATE DATE:  09/30/1999|
|  HQ OPS OFFICER:  WILLIAM POERTNER             +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RUDOLPH BERNHARD     R2      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INADVERTENT START OF THE "B" RESIDUAL HEAT REMOVAL (RHR) PUMP DURING         |
| MAINTENANCE ACTIVITIES                                                       |
|                                                                              |
| Electrical maintenance was removing a spare breaker in the "B" train 480     |
| volt switchgear (XSW-1DB1).  This cubicle is directly above the breaker      |
| cubicle for the "B" RHR pump breaker.  During the maintenance activity, a    |
| breaker transport cart inadvertently rolled against the supply breaker for   |
| the "B" RHR pump.  The lip of the cart activated the manual closing          |
| mechanism, on the front of the RHR pump breaker.  This resulted in starting  |
| the "B" RHR pump.  The pump ran for approximately six minutes before being   |
| secured, and placed in the pull-to-lock (PTL) position after it was verified |
| that no valid demand signal was present.  The pump remained in PTL for 29    |
| minutes while the investigation continued.                                   |
|                                                                              |
| The NRC Resident has been notified.                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36248       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM             REGION:  1  |NOTIFICATION DATE: 09/30/1999|
|    UNIT:  [2] [] []                 STATE:  PA |NOTIFICATION TIME: 22:38[EDT]|
|   RXTYPE: [2] GE-4,[3] GE-4                    |EVENT DATE:        09/30/1999|
+------------------------------------------------+EVENT TIME:        19:06[EDT]|
| NRC NOTIFIED BY:  PAT NAVIN                    |LAST UPDATE DATE:  09/30/1999|
|  HQ OPS OFFICER:  WILLIAM POERTNER             +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAVID SILK           R1      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR SCRAM DUE TO A TURBINE TRIP AND GENERATOR LOCKOUT                    |
|                                                                              |
| At 1906 EDT on 9/30/99 a reactor scram occurred due to a turbine trip and    |
| generator lockout.  During the transient three safety relief valves opened   |
| momentarily due to high reactor pressure and then reseated.  Reactor         |
| pressure peaked at approximately 1125 psi.  Additionally Group II and III    |
| Primary Containment Isolation System (PCIS) isolations occurred due to low   |
| reactor water level following the scram.  Minimum reactor level following    |
| the scram was approximately -15 inches.  All control rods fully inserted.    |
| Post scram recovery was normal and all scram and PCIS signals have been      |
| reset.  The licensee is investigating the cause of the reactor               |
| trip/generator lockout.                                                      |
|                                                                              |
| The NRC resident has been notified.                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36249       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 10/01/1999|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 03:19[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/30/1999|
+------------------------------------------------+EVENT TIME:        23:30[EDT]|
| NRC NOTIFIED BY:  STEVE SAUER                  |LAST UPDATE DATE:  10/01/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAVID SILK           R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| RHR PUMP DISCHARGE VALVE FAILED TO CLOSE ON DEMAND                           |
|                                                                              |
| The #12 Residual Heat Removal (RHR) pump motor operated discharge valve      |
| failed to close upon demand.  This valve is required by Emergency Operating  |
| Procedures to be closed during cold leg recirculation to provide long term   |
| containment spray.  The cause of the failure is currently under              |
| investigation.                                                               |
|                                                                              |
| The licensee will inform the NRC resident inspector and LAC Township.        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36250       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER            REGION:  2  |NOTIFICATION DATE: 10/01/1999|
|    UNIT:  [3] [] []                 STATE:  FL |NOTIFICATION TIME: 03:51[EDT]|
|   RXTYPE: [3] B&W-L-LP                         |EVENT DATE:        10/01/1999|
+------------------------------------------------+EVENT TIME:        01:14[EDT]|
| NRC NOTIFIED BY:  RICKY RAWLS                  |LAST UPDATE DATE:  10/01/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RUDOLPH BERNHARD     R2      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       4        Startup          |4        Startup          |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EMERGENCY FEEDWATER START                                                    |
|                                                                              |
| The unit was in the process of a normal plant shut down for a refueling      |
| outage when the running Main Feedwater pump (MFP-2A) tripped.  The tripping  |
| of the only running feedwater pump caused Emergency Feedwater to actuate     |
| (EFP-1 and EFP-2).  The plant did not experience any abnormal changes in     |
| OTSG level or other systems.  The cause of the MFP trip is unknown at this   |
| time.  The "B" MFP (MFP-2B) was started and emergency feedwater secured and  |
| reset.                                                                       |
|                                                                              |
| The licensee informed the NRC resident inspector.                            |
+------------------------------------------------------------------------------+