Event Notification Report for April 9, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/08/1999 - 04/09/1999
** EVENT NUMBERS **
35202 35451 35548 35556 35557 35558 35559 35560 35561 35562 35563 35564
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35202 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: FLORIDA DEPARTMENT OF HEALTH |NOTIFICATION DATE: 12/29/1998|
|LICENSEE: ALL STATE ENGINEERING & TESTING CONSU|NOTIFICATION TIME: 15:11[EST]|
| CITY: HIALCAH REGION: 2 |EVENT DATE: 12/29/1998|
| COUNTY: STATE: FL |EVENT TIME: [EST]|
|LICENSE#: FL 1113-1 AGREEMENT: Y |LAST UPDATE DATE: 04/08/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |PIERCE SKINNER R2 |
| | |
+------------------------------------------------+ |
| NRC NOTIFIED BY: CHARLES ADAMS | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| STOLEN TROXLER MOISTURE/DENSITY GAUGE |
| |
| On 12/29/98, the licensee discovered that a Troxler Model 3440 soil |
| moisture/density gauge (Serial #24596) had been removed from its case, which |
| was located in the back of a pickup truck. The gauge contains one 8-mCi |
| Cs-137 source, and one 40-mCi Am-241/Be source. When last seen on |
| 12/23/98, the gauge had been locked in its case, and the case had been |
| chained to the back of the pickup. A state investigator from the Miami |
| office has been dispatched to the scene, and the Metro-Dade police are |
| investigating the theft. |
| |
| * * * UPDATE AT 1131 EDT ON 4/8/99 BY CHARLES ADAMS TO FANGIE JONES * * * |
| |
| A fax from the Florida Department of Health Environmental Radiation Control |
| reported that a person, unknown, walked up to construction site personnel, |
| dropped off the gauge and left. Metro Dade Hazmat took possession of the |
| gauge. A survey showed normal readings. The owner has been contacted and |
| will take possession of the gauge. A leak test will be performed and |
| results passed to the state office. Metro Dade police is investigating. |
| |
| The NRC Operations Officer notified the R2DO (Walter Rogers) and NMSS (Don |
| Cool) |
+------------------------------------------------------------------------------+
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35451 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK REGION: 1 |NOTIFICATION DATE: 03/09/1999|
| UNIT: [1] [] [] STATE: PA |NOTIFICATION TIME: 05:55[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 03/09/1999|
+------------------------------------------------+EVENT TIME: 02:21[EST]|
| NRC NOTIFIED BY: JOHN HUNTER |LAST UPDATE DATE: 04/08/1999|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |TOM MOSLAK R1 |
|10 CFR SECTION: | |
|AINB 50.72(b)(2)(iii)(B) POT RHR INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| COMMON FAILURE EFFECTING BOTH TRAINS OF SHUTDOWN COOLING |
| |
| "On 3/9/99, at 0221 it was discovered that the Unit 1 shutdown cooling |
| valves HV-51-1F015A, HV-51-1F015B, and HV-51-1F08 could not be opened, if |
| plant conditions required, due to a failure in the isolation logic circuit |
| connectors. |
| |
| "This failure affected both shutdown cooling return valves and a common |
| suction valve which results in one failure effecting both trains of shutdown |
| cooling. The identified deficiency is being planned for repairs. This |
| condition, of a single failure disabling multiple trains of a system, is |
| being reported pursuant to 50.72(b)(2)(iii)." |
| |
| This deficiency was discovered during routine maintenance. These valves |
| could be opened manually using existing plant procedures if it were |
| necessary to initiate shutdown cooling. |
| |
| The licensee will notify the NRC resident inspector. |
| |
| * * * RETRACTION 1421 4/8/1999 FROM McCABE TAKEN BY STRANSKY * * * |
| |
| "This is a retraction of Event # 35451: Common Failure Effecting Both Trains |
| of Shutdown Cooling |
| |
| "During normal operator rounds in the Auxiliary Equipment room, an operator |
| noticed an extinguished NSSSS indicator light. An attempt to reset that |
| portion of the logic circuitry failed. Troubleshooting revealed that there |
| was an open connection across a Grayboot electrical connector. The connector |
| was replaced and the system was returned to normal. The Residual Heat |
| Removal (RHR) - Shutdown Cooling Mode (SCM) was not in demand at any time |
| during the incident. Had the failure existed during a loss of coolant event, |
| high drywell pressure would have prevented the common suction valve for both |
| loops of RHR-SCM from initially being used. |
| |
| "A lab analysis of the failed electrical Grayboot connector revealed an |
| over-crimping of the connector during initial installation. The failure was |
| attributable to improperly setting the crimping tool from its initial |
| calibration setting prior to performing the final crimp. Six other Grayboot |
| connectors from various other Limerick Unit 1 and Unit 2 systems were |
| removed and analyzed in the lab. No similar incidences of over-crimping were |
| found, therefore the identified condition is considered not to be a generic |
| concern. |
| |
| "A licensing basis review for shutdown cooling was performed. Updated Final |
| Safety Analysis Report (UFSAR) section 7.4.1.3.1.1 states that '...The |
| system can use a preferred method to accomplish its design objectives by |
| directly extracting reactor vessel water from the reactor vessel via the |
| recirculation loop and routing it to a heat exchanger and back to the |
| vessel. An alternate method is to indirectly extract the water via relief |
| valve discharge lines to the suppression pool and route the suppression pool |
| water to the heat exchanger and back to the vessel. The redundancy and |
| diversity of RHR-SCM is also discussed in UFSAR Section 7.4.1.3.3.5. Failure |
| of RHR - SCM is analyzed in UFSAR Section 15.2.9. Also, UFSAR Section |
| 15.9.2.4 discusses alternate path availability to accomplish the shutdown |
| cooling function. |
| |
| "In addition, plant procedures exist to respond to a Loss of Shutdown |
| Cooling. The Shutdown Cooling system is initiated by Off-Normal procedure |
| ON-I 21, loss of Shutdown Cooling. Also, the other mechanism for SCM was |
| available and is also procedurally governed by S41 .7.B Use of SRV's and |
| Suppression Pool Cooling as an Alternate Shutdown Cooling Method. |
| |
| "Based on our review of the licensing basis for shutdown cooling, we |
| determined that the Shutdown Cooling System was not rendered incapable of |
| performing its design safety function." |
| |
| The licensee will inform the NRC resident inspector of this retraction. |
| Notified R1DO (Costello). |
+------------------------------------------------------------------------------+
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35548 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK REGION: 3 |NOTIFICATION DATE: 04/06/1999|
| UNIT: [1] [2] [] STATE: MI |NOTIFICATION TIME: 08:00[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 04/06/1999|
+------------------------------------------------+EVENT TIME: 07:00[EDT]|
| NRC NOTIFIED BY: DON KOSLOFF |LAST UPDATE DATE: 04/08/1999|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |BRUCE BURGESS R3 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Cold Shutdown |0 Cold Shutdown |
|2 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY OF THE POTENTIAL COMPROMISE OF SAFEGUARDS INFORMATION. |
| |
| At 0700 EDT on 04/06/99, a potential compromise of safeguards information |
| was discovered. Immediate compensatory actions were taken upon discovery. |
| (Contact the NRC operations officer for additional details and for licensee |
| contact information.) |
| |
| This issue was reported as a 1-hour event notification in accordance with 10 |
| CFR 73.71(b)(1), Appendix G. |
| |
| The licensee plans to notify the NRC resident inspector. |
| |
| * * * RETRACTION 1552 EDT 4/8/1999 FROM DON KOSLOFF TAKEN BY STRANSKY * * * |
| |
| The licensee has retracted this notification. Contact HOO for additional |
| details. Notified R3DO (Burgess). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35556 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 04/08/1999|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 07:21[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 04/08/1999|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 07:20[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 04/08/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |BRUCE BURGESS R3 |
| DOCKET: 0707002 |HENRY BAILEY IRO |
+------------------------------------------------+FRANK CONGEL IRO |
| NRC NOTIFIED BY: DON FAUST |JOHN JOLICOEUR RCT |
| HQ OPS OFFICER: DOUG WEAVER |BILL SIMES EPA |
+------------------------------------------------+JOHN GREEVES NMSS |
|EMERGENCY CLASS: ALE | |
|10 CFR SECTION: | |
|AAEC 50.72 (a) (1) (I) EMERGENCY DECLARED | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LARGE OIL SPILL FROM A TRANSFORMER |
| |
| A TRANSFORMER CONTAINING 9500 GALLONS OF NON PCB OIL STARTED LEAKING AT |
| APPROXIMATELY 0530 BECAUSE OF AN ELECTRICAL FAULT. THE OIL IS HEADING |
| TOWARD POND J-6. EFFORTS ARE UNDERWAY TO CONTAIN THE SPILL, BUT IT IS NOT |
| KNOWN WHETHER THE OIL CAN BE PREVENTED FROM LEAVING THE SITE. |
| |
| THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR. |
| |
| IN ADDITION TO THE NOTIFICATIONS LISTED ABOVE HHS (GREEN) WAS NOTIFIED BY |
| THE OPERATIONS CENTER. |
| |
| * * * UPDATE AT 0817 ON 4/8/99, BY MACCRAE TAKEN BY WEAVER * * * |
| |
| THE TRANSFORMER HAS STOPPED LEAKING. RESPONSE PERSONNEL BELIEVE THEY WILL |
| BE ABLE TO CONTAIN THE LEAK TO THE J-6 POND. |
| |
| * * * UPDATE AT 1021 EDT ON 4/8/99 BY J. B. HALCOMB TO FANGIE JONES * * * |
| |
| As a result of this event the Ohio Environmental Protection Agency was |
| notified (0758 EDT) and a press release was issued (0958 EDT). Both of |
| these are criteria for a 4 hour notification to the NRC of themselves, but |
| are included here as they are part of the event previously reported. |
| |
| The NRC Operations Officer notified the R3DO (Bruce Burgess), NMSS (Steurz), |
| and the Office of Public Affairs. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35557 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NORTH CAROLINA DIV OF RAD PROT |NOTIFICATION DATE: 04/08/1999|
|LICENSEE: SYNCOR INTERNATIONAL CORP |NOTIFICATION TIME: 10:35[EDT]|
| CITY: Charlottle REGION: 2 |EVENT DATE: 10/30/1998|
| COUNTY: STATE: NC |EVENT TIME: 12:00[EDT]|
|LICENSE#: 060-0794-1 AGREEMENT: Y |LAST UPDATE DATE: 04/08/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |WALTER RODGERS R2 |
| |SCOTT MOORE NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: GRANT MILLS | |
| HQ OPS OFFICER: DOUG WEAVER | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - LOST DELIVERY CASES |
| |
| NC Division of Radiation Protection was informed April 8, 1999, by Syncor |
| International Corporation that one of their Nuclear Pharmacies lost control |
| of five delivery cases containing Limited Quantity Shipments (LQS) returned |
| from customers. The pharmacy is located in Charlotte, NC (Radioactive |
| License No. 060-0794-1). On October 30, 1998, the delivery cases were |
| inadvertently left within the trunk of a delivery vehicle which had been |
| rendered inoperable in an accident. The car was transferred through a series |
| of wrecker and garage services (without a set of keys), eventually being |
| sold to a resident of TN. The new owner purchased the vehicle on April 2, |
| 1999, in SC, returned it to TN and had keys made. The delivery cases were |
| discovered April 3, 1999, when the owner opened the trunk for the first |
| time. The owner notified TN authorities who were able to determine the |
| origin of the delivery by paper work located with the cases. TN authorities |
| contacted Syncor International Corporation which dispatched trained |
| employees to recover the delivery cases. Surveys performed at the time of |
| recovery indicated no exposure rates above background or indications of |
| contamination. |
| |
| |
| NC Division of Radiation Protection is working with the TN Dept. of |
| Environment and |
| Conservation Div. Of Radiological Health SC Agreement State Program and |
| Syncor |
| International Corporation to fully investigate this event. |
| |
| This event was sent by facsimile to the NRC Operations Center. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35558 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK REGION: 1 |NOTIFICATION DATE: 04/08/1999|
| UNIT: [1] [] [] STATE: NH |NOTIFICATION TIME: 11:12[EDT]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 04/08/1999|
+------------------------------------------------+EVENT TIME: 09:18[EDT]|
| NRC NOTIFIED BY: KILBY |LAST UPDATE DATE: 04/08/1999|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |FRANK COSTELLO R1 |
|10 CFR SECTION: | |
|NLTR LICENSEE 24 HR REPORT | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 24 HOUR REPORT - DEAD SEAL FOUND |
| |
| DIVERS FOUND A DEAD SEAL IN THE SERVICE WATER FOREBAY. THE LICENSEE |
| NOTIFIED THE NATIONAL MARINE FISHERIES SERVICE AND THE NRC RESIDENT |
| INSPECTOR. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35559 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ILLINOIS DEPT OF NUCLEAR SAFETY |NOTIFICATION DATE: 04/08/1999|
|LICENSEE: MEDI-PHYSICS |NOTIFICATION TIME: 13:50[EDT]|
| CITY: CHICAGO REGION: 3 |EVENT DATE: 04/07/1999|
| COUNTY: STATE: IL |EVENT TIME: [CDT]|
|LICENSE#: IL-01052-01 AGREEMENT: Y |LAST UPDATE DATE: 04/08/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |BRUCE BURGESS R3 |
| |DONALD COOL NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: BRUCE SANZA (EMAIL) | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONTAMINATED PACKAGE RECEIVED BY PHARMACY |
| |
| The following information was received via email from the State of |
| Illinois: |
| |
| "On April 7, 1999, Medi-Physics Pharmacy (IL-01052-01) in Chicago reported |
| that they received a package with removable contamination of 265,000 cpm. |
| The package was picked up and transported by the pharmacy's driver from West |
| Suburban Hospital in Oak Park, IL (IL-01520-01). The Illinois Department of |
| Nuclear Safety is conducting an investigation at the shipper's facility in |
| Oak Park into the cause of the event. The Illinois equivalent to 20.1906(d) |
| is 32 Ill. Adm. Code 340.960(d). The contaminant was Tc-99m." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35560 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK REGION: 1 |NOTIFICATION DATE: 04/08/1999|
| UNIT: [1] [] [] STATE: NH |NOTIFICATION TIME: 15:41[EDT]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 02/17/1999|
+------------------------------------------------+EVENT TIME: [EDT]|
| NRC NOTIFIED BY: KILBY |LAST UPDATE DATE: 04/08/1999|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |FRANK COSTELLO R1 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNESCORTED ACCESS GRANTED INAPPROPRIATELY. IMMEDIATE COMPENSATORY MEASURES |
| TAKEN UPON DISCOVERY. CONTACT HOO FOR ADDITIONAL DETAILS. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35561 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA REGION: 2 |NOTIFICATION DATE: 04/08/1999|
| UNIT: [1] [2] [] STATE: SC |NOTIFICATION TIME: 15:59[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 04/08/1999|
+------------------------------------------------+EVENT TIME: 15:14[EDT]|
| NRC NOTIFIED BY: KEN EVANS |LAST UPDATE DATE: 04/08/1999|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |WALTER RODGERS R2 |
|10 CFR SECTION: | |
|AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | |
|NLCO TECH SPEC LCO A/S | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONTROL ROOM VENTILATION INTAKES ISOLATED |
| |
| The Unit 2 Control Room Ventilation (VC) intake was isolated when valve |
| 2VC6A automatically closed due to a (suspected) invalid high chlorine |
| signal. During troubleshooting activities, a maintenance technician |
| inadvertently closed valve 1VC5B (the Unit 1 VC intake) when he depressed |
| the associated chlorine detector reset button. (The technician mistakenly |
| thought that the VC intake for Unit 1 was isolated.) Control room operators |
| immediately discovered the error and reopened valve 1VC5B. As a result of |
| this event, both units entered Technical Specification 3.0.3 for |
| approximately one minute. The NRC resident inspector will be informed of |
| this notification by the licensee. |
| |
| |
| HOO NOTE: See event #35564 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35562 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 04/09/1999|
| UNIT: [] [] [3] STATE: AL |NOTIFICATION TIME: 00:51[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 04/08/1999|
+------------------------------------------------+EVENT TIME: 20:45[CDT]|
| NRC NOTIFIED BY: TIM GOLDEN |LAST UPDATE DATE: 04/09/1999|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |WALTER RODGERS R2 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
| | |
|3 N Y 100 Power Operation |100 Power Operation |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HPCI TEMPORARILY INOPERABLE |
| |
| System Affected: During performance of regularly scheduled Instrumentation |
| surveillance on Unit 3 HPCI Steam Line Space High Temperature switches (in |
| accordance with plant procedure 3-SR-3.3.6.1(3D)) personnel noticed that a |
| relay not tested by procedure was chattering. The affected relay |
| 3-RLY-073-23A-K16 was adjacent to a relay 3-RLY-073-23A-K8 which was being |
| tested by the surveillance. While troubleshooting the cause of the |
| chattering relay, a loose wire was found in the power supply pathway for |
| the HPCI logic circuit. This loose wire had the potential to prevent |
| adequate voltage being supplied to the initiation and isolation logic for |
| the Unit 3 HPCI system. |
| |
| Actions: The loose wire was retightened. |
| |
| Reportability: The potential for inadequate voltage being available for the |
| HPCI logic circuit resulted in a conservative decision to declare the HPCI |
| system inoperable. In accordance with plant procedure SPP 3.5, code of |
| Federal Regulations 10CFR50.72/73 and NUREG 1022 Rev 1 this is reportable as |
| a 4 Hour Non-Emergency report due to any event or condition that alone could |
| have prevented the Fulfillment of the safely function of structures or |
| systems that are needed to (d) Mitigate the consequences of an accident.' |
| This criteria is specified in 10CFR50.72.b.2.iii as a 4 hour report and in |
| 10CFR50.73.a.2.v as a 30 day written report. |
| |
| The licensee notified the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35563 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 04/09/1999|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 02:50[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 04/08/1999|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 23:00[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 04/09/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |BRUCE BURGESS R3 |
| DOCKET: 0707002 |ROSEMARY HOGAN IRO |
+------------------------------------------------+SUSAN SHANKMAN NMSS |
| NRC NOTIFIED BY: KEITH VANDERPOOL | |
| HQ OPS OFFICER: DOUG WEAVER | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NBNL RESPONSE-BULLETIN | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| BULLETIN 91-01 REPORT - VIOLATION OF NCSA |
| |
| "ON 4/8/99, AT 2300 HOURS IT WAS DISCOVERED THAT REQUIREMENT #14 OF |
| NCSA-0333_ 015.E03 WAS NOT BEING MAINTAINED ON CELL 33-3-8 WITHIN THE X-333 |
| PROCESS BUILDING. REQUIREMENT #14 STATES IN PART 'IF THE MOTORS ARE OFF, |
| EITHER THE RCW CONTROL VALVE OR THE RCW SUPPLY BLOCK VALVE SHALL BE CLOSED |
| WITHIN 4 HOURS.' THE MOTORS WERE IN FACT OFF AND THE RCW CONTROL VALVE |
| FAILED IN THE OPEN POSITION AND THE RCW SUPPLY VALVE WAS NOT CLOSED WITHIN 4 |
| HOURS, THUS VIOLATING REQUIREMENT #14. VIOLATION OF THIS REQUIREMENT |
| CONSTITUTES A LOSS OF CONTROL "B" (MODERATION) IN THE DOUBLE CONTINGENCY |
| MATRIX FOR CONTINGENCY EVENT B.6.b.1. CONTROL 'A' WHICH IS THE PASSIVE |
| BARRIER PROVIDED BY THE |
| CONDENSER AND COOLER TUBES REMAINED IN PLACE THROUGHOUT THIS EVENT. |
| CONTROL WAS NOT ESTABLISHED WITHIN THE 4 HOUR SPECIFIED TIME FRAME THUS |
| MAKING THIS A 4 HOUR NRC EVENT. CONTROL HAS BEEN ESTABLISHED AND CELL |
| 33-3-8 IS NOW ONSTREAM. (MOTORS ON)" |
| |
| THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35564 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA REGION: 2 |NOTIFICATION DATE: 04/09/1999|
| UNIT: [1] [2] [] STATE: SC |NOTIFICATION TIME: 05:15[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 04/09/1999|
+------------------------------------------------+EVENT TIME: 04:28[EDT]|
| NRC NOTIFIED BY: HOLLAND |LAST UPDATE DATE: 04/09/1999|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |WALTER RODGERS R2 |
|10 CFR SECTION: | |
|AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | |
|NLCO TECH SPEC LCO A/S | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PLANT ENTERED 3.0.3 DUE TO BOTH TRAINS OF CONTROL ROOM VENTILATION BEING |
| INOPERABLE. |
| |
| A SPURIOUS SIGNAL ON THE CHLORINE DETECTOR ON UNIT 1 "B" TRAIN CONTROL ROOM |
| VENTILATION INTAKE WAS RECEIVED WHILE UNIT 2 VENTILATION INTAKE WAS CLOSED. |
| UNIT 2 CONTROL ROOM INTAKE HAD PREVIOUSLY CLOSED ON A SPURIOUS SIGNAL( SEE |
| EVENT 35561) AND IT WAS STILL CLOSED FOR TROUBLESHOOTING. BOTH UNITS |
| CONTROL ROOM VENT SYSTEMS BEING CLOSED RESULTS IN THE INOPERABILITY OF BOTH |
| TRAINS OF CONTROL ROOM VENTILATION, PLACING BOTH UNITS IN TS 3.0.3. |
| |
| THE RESIDENT INSPECTOR WILL BE NOTIFIED. |
| |
| *** UPDATE AT 0530 BY HOLLAND TO GOULD *** |
| |
| THEY EXITED 3.0.3 AT 0526 WHEN THE "B" TRAIN WAS RESTORED TO OPERABLE |
| CONDITION. |
| |
| THE RESIDENT INSPECTOR WILL BE NOTIFIED. |
+------------------------------------------------------------------------------+