Event Notification Report for February 2, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 02/01/1999 - 02/02/1999 ** EVENT NUMBERS ** 35336 35337 35338 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35336 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SAN ONOFRE REGION: 4 |NOTIFICATION DATE: 02/01/1999| | UNIT: [] [2] [] STATE: CA |NOTIFICATION TIME: 13:30[EST]| | RXTYPE: [1] W-3-LP,[2] CE,[3] CE |EVENT DATE: 02/01/1999| +------------------------------------------------+EVENT TIME: 10:09[PST]| | NRC NOTIFIED BY: BOB CONOSCENTI |LAST UPDATE DATE: 02/01/1999| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: UNU |JEFF SHACKELFORD R4 | |10 CFR SECTION: |ROBERT DENNIG EO | |AAEC 50.72(a)(1)(i) EMERGENCY DECLARED |STUART RUBIN IRO | | |GENE CANUPP FEMA | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N N 0 Refueling |0 Refueling | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | UNIT 2 DECLARED AN UNUSUAL EVENT DUE TO A LOSS OF SHUTDOWN COOLING GREATER | | THAN 10 MINUTES | | | | MAINTENANCE PERSONNEL WERE PREPARING TO RACK OUT ELECTRICAL BREAKER | | "2A04-18", WHEN THE BREAKER UNEXPECTEDLY CLOSED. THIS BREAKER, WHICH WAS | | OUT-OF-SERVICE AT THE TIME, SUPPLIES POWER TO THE 4160 VAC CLASS 1-E BUS | | "2A04" FROM THE RESERVE AUXILIARY TRANSFORMER. AS A RESULT, AT 1009 PST THE | | "2A04" BUS DEENERGIZED CAUSING A LOSS OF BOTH THE OPERATING TRAIN "A" | | SHUTDOWN COOLING PUMP AND THE CROSS-TIED CONTAINMENT SPRAY PUMP "A" WHICH | | WAS SUPPLYING SPENT FUEL POOL COOLING. THE STANDBY EMERGENCY DIESEL | | GENERATOR AUTOSTARTED BUT DID NOT CLOSE ONTO THE BUS DUE TO A PROTECTIVE | | RELAY LOCKOUT. CORE ALTERATIONS WERE SUSPENDED. AT 1014 PST, THE "2A04" | | BUS WAS REENERGIZED AND AT 1025 PST SHUTDOWN COOLING FLOW WAS RESTORED. | | DURING THE 16 MINUTES THAT SHUTDOWN COOLING WAS LOST, INDICATED TEMPERATURE | | AS MEASURED BY TWO (2) SENSORS IN DIFFERENT LOCATIONS INCREASED FROM 72�F TO | | 74�F AND 77�F TO 80�F, RESPECTIVELY. | | | | UNIT 3 WAS IN THE PROCESS OF VERIFYING OFFSITE POWER SUPPLIES AS REQUIRED BY | | SURVEILLANCE SINCE THE "2A04" BUS CAN BE CROSS-TIED TO UNIT 3. | | | | THE LICENSEE IS CONDUCTING AN INVESTIGATION TO DETERMINE ROOT CAUSE. UNIT 2 | | EXITED THE UNUSUAL EVENT AT 1040 PST. THE LICENSEE INFORMED THE STATE AND | | THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35337 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 02/01/1999| | UNIT: [] [2] [] STATE: GA |NOTIFICATION TIME: 17:30[EST]| | RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 02/01/1999| +------------------------------------------------+EVENT TIME: 16:10[EST]| | NRC NOTIFIED BY: BRUCE BUTLER |LAST UPDATE DATE: 02/01/1999| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |BRIAN BONSER R2 | |10 CFR SECTION: | | |AESF 50.72(b)(2)(ii) ESF ACTUATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N N 0 Cold Shutdown |0 Cold Shutdown | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | UNIT 2 EXPERIENCED A SPURIOUS ESF ACTUATION OF TWO DRYWELL ISOLATION VALVES | | DURING BULB REPLACEMENT ON THE DRYWELL WIDE RANGE RADIATION MONITOR. | | | | "I&C PERSONNEL WERE REPLACING THE GREEN NORMAL/RESET PUSHBUTTON LIGHT BULB | | FOR DRYWELL WIDE RANGE RADIATION MONITOR '2D11-K621B' WHEN THE AMBER HIGH | | LIGHT LIT UP ON THE MONITOR RESULTING IN TWO 18 INCH PRIMARY CONTAINMENT | | PURGE AND VENT VALVES, '2T48-F320' AND '2T48-F308', GOING CLOSED. THE | | NORMAL/RESET PUSHBUTTON WAS BEING DEPRESSED IN THE LIGHT HOLDER WHEN THE | | AMBER HIGH LIGHT CAME ON AND IMMEDIATELY RESET. THIS EVENT WAS CAUSED BY A | | SPURIOUS SIGNAL. [THERE WAS NO ACTUAL] HIGH RADIATION CONDITION IN THE | | DRYWELL. A DEFICIENCY IS BEING INITIATED [AS PART OF THE INVESTIGATION]. " | | | | BOTH VALVES WERE SUBSEQUENTLY REOPENED AND THE LICENSEE WILL INFORM THE NRC | | RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35338 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: FT CALHOUN REGION: 4 |NOTIFICATION DATE: 02/01/1999| | UNIT: [1] [] [] STATE: NE |NOTIFICATION TIME: 23:30[EST]| | RXTYPE: [1] CE |EVENT DATE: 02/01/1999| +------------------------------------------------+EVENT TIME: 20:15[CST]| | NRC NOTIFIED BY: LARRY LEES |LAST UPDATE DATE: 02/01/1999| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JEFF SHACKELFORD R4 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE ASSISTANCE REQUESTED FROM THE BLAIR VOLUNTEER FIRE DEPARTMENT DUE TO | | A REPORT OF SMOKE IN THE TRAINING FACILITY. | | | | WHILE CLEANING THE NORTHEAST END OF TRAINING FACILITY, WHICH IS LOCATED | | OUTSIDE THE PROTECTED AREA, SMOKE AND A BURNING SMELL WERE NOTED BY A MEMBER | | OF THE JANITORIAL STAFF. THE CONTROL ROOM WAS NOTIFIED AND DISPATCHED AN | | OPERATOR WITH A SECURITY GUARD TO INVESTIGATE. ASSISTANCE WAS REQUESTED | | FROM THE BLAIR VOLUNTEER FIRE DEPARTMENT (VFD) WHO RESPONDED TO THE SCENE. | | THE SOURCE OF THE SMOKE WAS A FAILED RESISTIVE HEATING ELEMENT IN THE | | VENTILATION DUCTING. POWER WAS REMOVED FROM THE HEATER AT 2115 CDT AND THE | | BLAIR VFD WAS RELEASED. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021