In resolving GSIs over the years, the staff generally found it necessary to make assumptions and establish limitations on the scope of the issues. As a result of its review of the resolution of some GSIs, the ACRS expressed concerns that the assumptions …
DESCRIPTION Historical Background This issue was identified when it was believed [1] that the validity of steam generator (SG) tube leak and rupture analyses could be affected by resonance vibrations in steam generator tubes during steam line break …
DESCRIPTION The risk of failure from fatigue of various reactor coolant system components was studied under Issue 78 and later integrated into the NRR Fatigue Action Plan which was completed and documented in SECY-95-245. [1] The staff concluded that the …
DESCRIPTION Historical Background This issue was initiated [1] in response to a recommendation in the screening analysis of Generic Issue (A)             I-195, "Potential Hydrogen Combustion in BWR Piping." GI-195 investigated the potential safety …