Item B-63: Isolation of Low Pressure Systems Connected to the Reactor Coolant Pressure Boundary

DESCRIPTION

There are several systems connected to the reactor coolant pressure boundary that have design pressures that are considerably below the reactor coolant system operating pressure. The NRC has required that valves forming the interface between these high and low pressure systems have sufficient redundancy to assure that the low pressure systems are not subjected to pressures which exceed their design limits.

Recently, there has been discussion relative to the adequacy of the isolation of low pressure systems that are connected to the reactor coolant pressure boundary. Past reviews have concentrated on ensuring isolation of the residual heat removal system, which is a low pressure system on almost all PWRs and BWRs. Current reviews of license applications for new plants (CP/OL evaluations) are based on guidelines set forth in the SRP[1]supplemented by the staff position, "Leak Testing of Pressure Isolation Valves," which is documented in the proposed Revision 2 to SRP[2]3.9.6 issued for public comment in 1980. These guidelines were not available during the reviews of the plants which are currently operating. The next revision of SRP[3]3.9.6 will include the staff position on leak testing pressure isolation valves.

To assess the isolation capabilities of low pressure systems, this NUREG-0471[4]task involves the review of a representative operating plant for each NSSS vendor. Each low pressure system connected to the reactor coolant pressure boundary and penetrating the containment will be examined.

In April 1981, an order was issued[5]to all operating reactors to comply with the requirements of the technical resolution for Event V configurations. All other configurations are being addressed by inservice testing SERs and are being issued as license amendments.

CONCLUSION

This issue has been RESOLVED and requirements have been issued.

 

 

[4] NUREG-0471, "Generic Task Problem Descriptions (Categories B, C, and D)," U.S. Nuclear Regulatory Commission, June 1978.

[5] Letter to Arkansas Power & Light Company from U.S. Nuclear Regulatory Commission, "Order for Modification of License Concerning Primary Coolant System Pressure Isolation Valves," (Docket No. 50-313), April 20, 1981. [ML021220493]

Page Last Reviewed/Updated Tuesday, March 24, 2026

Disclaimer: Some of the formatting in NUREG-0933 may not be correct. We are currently working on fixing the formatting.

Page Last Reviewed/Updated Tuesday, March 24, 2026