Morning Report for September 23, 1999

… feedwater actuation signal (AFAS) occurred due to low steam generator water level. The preliminary cause was determined to be personnel error (plant electrician) during the performance of maintenance which … Carolina Power & Light Co. MR Number: 2-99-0014 Brunswick 1 2 Date: 09/23/99 Southport,North Carolina …

Information Notice No. 86-12: Target Rock Two-Stage SRV Setpoint Drift

… The owners' group that formed after this event, General Electric Company (GE), and the Target Rock Company … Hatch event, the tests performed at Wyle had consisted of a steam pressure test to determine the setpoint, followed by … the amount to which the disc is stuck, the test of the Brunswick valves, and the current test procedure, calls for …

Information Notice No. 83-53: Primary Containment Isolation Valve Discrepancies

… to conflict with the actual logic and an examination of the electrical diagrams indicated that the sample valves only … are low low reactor water level (level 2) and high main steam line radiation. This was verified to be consistent … specifications surveillance requirements were reviewed at Brunswick Station. The listed group 1 isolation valves were …

Morning Report for September 10, 2002

… 09/10/02 Subject: Part 21 - Incorrect lacquer applied to electrical cable could contribute to flame propagation … Subject: Part 21-Inadequate vibratory loads on main steam isolation valves with one main steam isolation valve … supply system vendor, reported that its 1988 analysis for Brunswick Units 1 and 2 full power operation with one main …

Event Notification Report for August 26, 2002

… | UNANALYZED CONDITION CONCERNING STEAM GENERATOR ATMOSPHERIC RELIEF VALVE | | BYPASS VALVES | … | REP ORG: GENERAL ELECTRIC COMPANY |NOTIFICATION DATE: 08/23/2002| |LICENSEE: … is that a | | 1988 GE Nuclear Energy (GE) analysis for Brunswick Units 1 and 2 full power | | operation with one …

Preliminary Notification (PN) Reports for 2005

… Material - Update PNO-II-05-013A 12/19/2005 Update-Vogtle Electric Generating Plant, Unit 2: Shutdown to Repair … of an Air Handler Unit PNO-II-05-006A 09/15/2005 Brunswick Steam Electric Plant Units 1 & 2: Notification of Unusual …

Event Notification Report for December 10, 2010

… Rep Org: NC DIV OF RADIATION PROTECTION Licensee: HAYNES ELECTRIC CONSTRUCTION COMPANY Region: 1 City: … isolation of the leaking waterbox. Sodium levels in the Steam Generators increased and a unit shutdown was required. … Inspector. Power Reactor Event Number: 46473 Facility: BRUNSWICK Region: 2 State: NC Unit: [1] [2] [ ] RX Type: [1] …