Search Results
… 43369 43370 Power Reactor Event Number: 43353 Facility: POINT BEACH Region: 3 State: WI Unit: [1] [2] [ ] RX Type: [1] … encompass the remainder of the safe shutdown areas in both Point Beach Nuclear Plant (PBNP) units. The results of the …
Event Notification Report for May 18, 2007
… 43369 43370 Power Reactor Event Number: 43353 Facility: POINT BEACH Region: 3 State: WI Unit: [1] [2] [ ] RX Type: [1] … encompass the remainder of the safe shutdown areas in both Point Beach Nuclear Plant (PBNP) units. The results of the …
Event Notification Report for April 7, 2003
… | FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 04/03/2003| | UNIT: [1] … | FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 04/04/2003| | UNIT: [1] … | FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 04/04/2003| | UNIT: [1] …
Part 21 Report - 1997-572
… that some of the poles were tripping outside the setpoint calibration range. These breakers were verified to be … recommendations. ASSESSMENT OF SAFETY SIGNIFICANCE The setpoint on a HMCP breaker is selected to provide circuit … Units 1 & 2 Turkey Point Unit 3 Wolf Creek Callaway Point Beach Unit 1 Yonggwang Units 1 & 2 Maanshan Units 1 & 2 …
Information Notice No. 83-24: Loose Parts in the Secondary Side of Steam Generators at Pressurized Water Reactors
… testing and were plugged as a conservative measure. Turkey Point 4 developed primary to secondary steam generator … 1/2" x 4." Visual inspection of the secondary side of the Point Beach steam generators in November 1982 revealed a large …
Information Notice No. 84-58: Inadvertent Defeat of Safety Function Caused by Human Error Involving Wrong Unit, Wrong Train, or Wrong System
… of each of the redundant containment spray pumps for Turkey Point Unit 3. The activity was required by the procedure for … that many events were highly significant from the standpoint of safety and others would have been significant if … (CEAs) instead of the assigned Unit 1 CEAs. Point Beach An operator was instructed to perform part 04/22/82 of …
Part 21 Report - 1997-193
… 06424 Consolidated Edison Company of New York, Inc. Indian Point Station #2 Mr. Stephen E. Quinn Vice President, … R. 333 Russellville, AR 72801 Florida Power & Light Turkey Point Station C. J. Baker, Plant Manager P. O. Box 4332 … Lucie Plt. Site Purchasing Supervisor P. O. Box 1200 Jensen Beach, FL 34958-1200 Florida Power & Light Co. Turkey Point …
Power Reactor Status Report for May 4, 2002
… GINNA 1 100 HOPE CREEK 1 100 INDIAN POINT 2 100 INDIAN POINT 3 100 LIMERICK 1 100 LIMERICK 2 100 … TO OFFSITE ELECTRICAL DISTRIBUTION SYSTEM WORK NEAR POINT BEACH * LASALLE 1 100 LASALLE 2 100 …
Power Reactor Status Report for March 13, 2010
… Ginna 100 Hope Creek 1 100 Indian Point 2 0 03/10/2010 REFUELING OUTAGE FEEDER 95891 AND BACKUP 13.8 KV FEEDER 13W92 OOS Indian Point 3 100 FEEDER 95891 AND BACKUP 13.8 KV FEEDER 13W92 … 100 Kewaunee 100 CONTINGENCY ALIGNMENT WITH POINT BEACH La Salle 1 100 La Salle 2 100 …