Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Search Results

Displaying 101 - 110 of 455

Event Notification Report for March 20, 2000

… feedwater around | | the normal feedwater heaters into the steam generators. During the resultant | | sudden … CENELEC (flameproof), CSA and | | FM (explosion proof) electrical classification requirements are also | | … | FACILITY: BRUNSWICK REGION: 2 |NOTIFICATION DATE: 03/19/2000| | UNIT: …

Event Notification Report for April 29, 2013

… R2DO (Sykes). Power Reactor Event Number: 48972 Facility: BRUNSWICK Region: 2 State: NC Unit: [1] [2] [ ] RX Type: [1] … Due to the shared configuration of the onsite AC Electrical Distribution System, this event is applicable to … body of 1E51-F076, Reactor Core Isolation Cooling system steam supply inboard isolation bypass warmup valve. This …

Event Notification Report for March 23, 2020

… was a loss of voltage on the Bravo train safety related electrical bus due to the EDG output breaker opening. The … to Unit 2. Power Reactor Event Number: 54597 Facility: BRUNSWICK Region: 2     State: NC Unit: [1] [] [] RX Type: … plant procedures, the main control room closed all Main Steam Line Isolation Valves (MSIVs) to arrest the cooldown …

Event Notification Report for August 17, 2009

… of many weeks. Power Reactor Event Number: 45264 Facility: BRUNSWICK Region: 2 State: NC Unit: [1] [ ] [ ] RX Type: [1] … inadvertent high ambient temperature signal from the HPCI steam leak detection module. Local temperatures were … The site is aligning the ring bus for the normal shutdown electrical lineup. Reactor water level is being maintained …

Event Notification Report for December 5, 2003

… RETRACTED !!!!! Power Reactor Event Number: 40318 Facility: BRUNSWICK Region: 2 State: NC Unit: [ ] [2] [ ] RX Type: [1] … pressure. HPCI is currently inoperable. The outboard steam line isolation valve closed automatically and the … emergency diesel generators are available and the offsite electrical grid is in a normal configuration. No safety …

Event Notification Report for September 25, 2001

… UNIVERSITY |NOTIFICATION TIME: 16:40[EDT]| | CITY: NEW BRUNSWICK REGION: 1 |EVENT DATE: 09/24/2001| | COUNTY: … to both Salem units. Auxiliary feedwater started on | | low steam generator level after isolation of main feedwater due … Hot | | Standby and an investigation into the cause of the electrical disturbance is | | underway. | | | | Two of four …

Event Notification Report for July 7, 2016

… MANUAL REACTOR TRIP AND UNUSUAL EVENT DECLARATION DUE TO STEAM LEAK IN TURBINE BUILDING "On July 6, 2016, at 0038 … generators to the main condenser. "Offsite power and plant electrical line ups are normal with the exception of 13.8kV … the event. Power Reactor Event Number: 52069 Facility: BRUNSWICK Region: 2 State: NC Unit: [1] [2] [ ] RX Type: [1] …

ACRS 2018 Letter Reports

… of the License Renewal Application for the Waterford Steam Electric Station, Unit 3 12/20/2018 11/15/2018 Report on the … the APR1400 Pressurized Water Reactor 07/30/2018 07/19/2018 Brunswick Steam Electric Plant, Units 1 and 2, Maximum …

Event Notification Report for June 14, 2012

… Power Reactor Event Number: 48019 Facility: BRUNSWICK Region: 2 State: NC Unit: [1] [2] [ ] RX Type: [1] … System (ERFIS) uninterruptible power supply (UPS) electrical bus 'A'. This resulted in a loss of site Safety … at 1700 CDT, it was determined that valve 2-FCV-73-81 (HPCI steam line warm-up valve) was not capable of performing its …