… … 95150 ACCESSION #: 9507030139 VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 June 27, 1995 U. S. … There are seven Model 1154SH9 pressure transmitters at North Anna: three installed in Unit 1 for pressurizer pressure, …
Part 21 Report - 1995-154
… … 95150 ACCESSION #: 9507030139 VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 June 27, 1995 U. S. … There are seven Model 1154SH9 pressure transmitters at North Anna: three installed in Unit 1 for pressurizer pressure, …
Part 21 Report - 1996-281
… President & General Manager cc: WRC EPM EDS SS-810-3 HHT Northeast Nuclear 28 pcs. Millstone Nuclear Plant P.O. 512959 I.D. R15KA0506B New York Power Authority 20 pcs. Indian Point Unit III P.O. B95I9120 … I.D. R15LM0540 SS-600-3 HMD Virginia Power 10 pcs. North Anna Station P.O. BNT433884 Rel 167 I.D. R15LJ0508B SS-600-3 …
Part 21 Report - 1995-020
… has been transmitted to the following affected nuclear power stations: Millstone 1&2, ANO, Prairie-Island 1&2, … River 3, E.I. Hatch Plant, Duane Arnold Energy Center 1, North Anna 1&2, Farley 1&2, Fermi 2, and Limerick 1&2. If …
Part 21 Report - 1996-280
… P.O. PL350399 387346 I.D. R14DI0500 6 pcs. Indiana Michigan Power Co. P.O. 06379-041-4X I.D. R14FC0538B 14 pcs. … BNT 448898 Rel 155 I.D. R15K30519B 1 pc. Virginia Power North Anna Station BNT 448898 Rel 150 R15K30519B 20 pcs. SS-600-3 …
Part 21 Reports: 2024
… 12/28/2024 ML24365A117 2024-36-01 FitzPatrick Nuclear Power Plant Closure of Interim Report of a Deviation … Part#80-921-4031-9 10/28/2024 ML24303A185 2024-32-01 North Anna Power Station Interim Report of a Deviation Associated …
Part 21 Reports - 2011
… Clutch Lug Failure 11/29/2011 ML11334A077 2011-52-00 North Anna 3 Early Site Permit Postulated Seismic Acceleration is … 10/14/2011 ML11287A036 2011-50-01 Baldor Electric Co Motor Power Leads Undersized 12/22/2011 ML12003A224 2011-50-00 …
Part 21 Reports
… ML25160A205 2025-08-01 James A FitzPatrick Nuclear Power Plant 10 CFR 21 Notification for GE Hitachi Molded … (Model #DD945E118P0060) 11/14/2024 ML24320A089 2024-32-01 North Anna Power Station Interim Report of a Deviation …
Part 21 Reports - 2007
… Areva Nonconservative Calculation of Minimum Critical Power Ratio 10/08/2007 EN 43701 ML072830334 2007-28-00 … on DB-25 Circuit Breaker 08/02/2007 ML072180044 2007-21-00 North Anna High Internal Resistance Readings of EDG Battery Cells …