Morning Report for September 23, 1999

… feedwater actuation signal (AFAS) occurred due to low steam generator water level. The preliminary cause was determined to be personnel error (plant electrician) during the performance of maintenance which … Carolina Power & Light Co. MR Number: 2-99-0014 Brunswick 1 2 Date: 09/23/99 Southport,North Carolina …

Morning Report for September 10, 2002

… 09/10/02 Subject: Part 21 - Incorrect lacquer applied to electrical cable could contribute to flame propagation … Subject: Part 21-Inadequate vibratory loads on main steam isolation valves with one main steam isolation valve … supply system vendor, reported that its 1988 analysis for Brunswick Units 1 and 2 full power operation with one main …

Morning Report for December 14, 1999

… 14, 1999 Licensee/Facility: Notification: Public Service Electric & Gas Co. MR Number: H-99-0105 Salem 2 Date: … Part 21 - Pressure switch indication problems on main steam isolation valve-actuator assemblies Discussion: … vendor, Teledyne Analytical Instruments, reports that the Brunswick licensee observed nonlinear oxygen readings with …