Skip to main content

Search Results

Displaying 1 - 8 of 8

EA-01-032 - Seabrook 1 (North Atlantic Energy Service Corp.)

… EA-01-032 - Seabrook 1 (North Atlantic Energy Service Corp.) … June 29, … Executive Vice President and Chief Nuclear Officer Seabrook Station North Atlantic Energy Service Corporation c/o Mr. … event. Our March 2, 2001, letter also provided you an opportunity to attend a Regulatory Conference or submit a written …

EA-98-165 - Seabrook 1 (North Atlantic Energy Service Corp.)

… EA-98-165 - Seabrook 1 (North Atlantic Energy Service Corp.) … August 3, … Executive Vice President and Chief Nuclear Officer Seabrook Station North Atlantic Energy Service Corporation c/o Mr. … S. Comley, Executive Director, We the People of the United States W. Meinert, Nuclear Engineer ENCLOSURE NOTICE …

EA-98-073 - Seabrook 1 (North Atlantic Energy Service Corp.)

… EA-98-073 - Seabrook 1 (North Atlantic Energy Service Corp.) … April 1, … Executive Vice President and Chief Nuclear Officer Seabrook Station North Atlantic Energy Service Corporation c/o Mr. … of attention toward licensed responsibilities since opportunities existed, in each case, to correct these adverse …

Escalated Enforcement Actions Issued to Reactor Licensees - S

… information. Saint Lucie 1 & 2 Salem 1 & 2 San Onofre 2 & 3 Seabrook 1 Sequoyah 1 & 2 South Texas 1 & 2 Summer Surry 1 & … internal flood barriers in conduits that penetrated the Unit 1 Reactor Auxiliary Building (RAB) exterior wall at … Level III violation and involved a keycard photobadge station problem that could have resulted in an unauthorized …

EA-98-338 - Williams Power Corporation

… at North Atlantic Energy Service Corporation's (NAESCo) Seabrook Station. Based on the findings of the investigation, … of your response to the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC …

NOEDs Issued to Power Reactor Licensees

… NOTICE OF ENFORCEMENT DISCRETION FOR HOPE CREEK GENERATING STATION (EPID: L-2025-LLD-0002)  2024 Confirmation Date NOED … 03/25/2024 EA-24-033 Diablo Canyon Power Plant, Unit 2 (EPID L-2024-LLD-0002) 03/05/2024 EA-24-027 Seabrook Station, Unit 1 (EPID L-2024-033) 2023 Confirmation …

EA-96-034 - Millstone 1, 2, 3 (Northeast Nuclear Energy Company)

… were reviewed during these inspections at all three units, a principal focus of the inspections was the handling … which contributed to the problems at the Millstone Station. Certain additional violations identified subsequent … ensure that similar management oversight is maintained at Seabrook, and (4) the importance of sending a similar …

EA-96-001 - Haddam Neck (Northeast Utilities Service Company)

… in the analyses. This deficiency, for which several opportunities existed to identify and correct it over the years, … as effective management and oversight at your Millstone and Seabrook facilities, and (3) the importance of emphasizing … 1992, which determined the design duty cycle of the 125 Vdc station batteries, did not assume the design basis event …