The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Basis Document for Large Early Release Frequency (LERF) Significance Determination Process (SDP): Inspection Findings that May Affect LERF (NUREG-1765)

On this page:

Download complete document

Publication Information

Manuscript Completed: November 2002
Date Published: December 2002

Division of Risk Analysis and Applications
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, D.C. 20555-0001

Availability Notice

Abstract

A significance determination process (SDP) is proposed that assigns risk characterization to inspection findings based on large early release frequency (LERF) considerations. This process is designed to interface directly with the SDP that is based on findings related to those structures, systems, and components (SSCs) that can influence the core damage frequency (CDF). The proposed LERF-based SDP will capture findings for those SSCs that can influence CDF determinations but which can also influence LERF. In addition, the proposed LERF-based SDP approach will address findings related to SSCs that do not influence CDF determinations but which can impact the containment function.

Page Last Reviewed/Updated Tuesday, March 09, 2021