Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Reassessment of NRC's Dollar Per Person-Rem Conversion Factor Policy, Final Report (NUREG-1530, Revision 1)

On this page:

Download complete document

Publication Information

Manuscript Completed: February 2022
Date Published: February 2022

Office of Nuclear Material Safety and Safeguards
U. S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Pamela Noto, NRC Project Manager

Availability Notice

Abstract

The U.S. Nuclear Regulatory Commission (NRC) uses the dollar per person-rem conversion factor in developing cost-benefit analyses to determine the monetary valuation of the consequences associated with radiological exposures. In 1995, the NRC issued NUREG-1530, "Reassessment of NRC’s Dollar per Person-Rem Conversion Factor Policy," which updated the dollar per person-rem conversion factor from $1,000 to $2,000 (in constant dollars) (NRC, 1995a). The $2,000 per person-rem conversion factor serves only as a proxy for the health effects associated with a person-rem of dose. This number resulted from the multiplication of the value of a statistical life (VSL) ($3 million in 1995) by the risk coefficient for stochastic health effects (7.3 × 10-4 per person-rem), rounded to the nearest thousand. A reevaluation of the $2,000 per person-rem conversion factor is appropriate because estimates and bases for the VSL and cancer mortality risk coefficients have changed since the NRC published NUREG-1530 in 1995.

Revision 1 to NUREG-1530 incorporates updates to the dollar per person-rem conversion factor and establishes a method for keeping this factor up-to-date. The dollar per person-rem conversion factor has been updated from $2,000 (in constant dollars) to $5,200 in 2014 dollars based on the application of an updated best estimate VSL of $9.0 million and the U.S. Environmental Protection Agency’s cancer mortality risk coefficient of 5.8 × 10-4 per person-rem. Revision 1 to NUREG-1530 uses a conversion factor with two significant figures instead of rounding to the nearest $1,000 value and provides guidance to the staff on when to use a higher dollar per person-rem conversion factor.

Page Last Reviewed/Updated Wednesday, February 23, 2022

Page Last Reviewed/Updated Wednesday, February 23, 2022