Critical Heat Flux Data Used to Generate the 2006 Groeneveld Lookup Tables (NUREG/KM-0011)

On this page:

Download complete document

Publication Information

Manuscript Completed: July 2016
Date Published: January 2019

Prepared by:
D.C. Groeneveld

Thermalhydraulics Consultants, Inc.
P.O. Box 1335
Deep River, Ontario, Canada
K0J 1P0

Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

This report contains a compilation of over 25,000 critical heat flux (CHF) data points obtained in water-cooled tubes that were used to derive the 2006 Groeneveld CHF lookup table. This compilation is based on 62 data sets that have been obtained during the past 60 years. This NUREG report describes the pertinent experimental details and possible concerns for these data sets. It also discusses the applicability and validity of the CHF lookup table to reactor conditions of interest and includes a graphical comparison of the ranges of conditions covered by these primary data and subsequently obtained supplementary data sets.