Bias Estimates Used in Lieu of Validation of Fission Products and Minor Actinides in MCNP Keff Calculations for PWR Burnup Credit Casks (NUREG/CR-7205, ORNL/TM-2012/544)
On this page:
Download complete document
Publication Information
Manuscript Completed: May 2014
Date Published: September 2015
Prepared by:
D. E. Mueller, W. J. Marshall, D. G. Bowen, and J. C. Wagner
Oak Ridge National Laboratory
Managed by UT-Battelle, LLC
Oak Ridge, TN 37831-6170
A. Barto, Project Manager
NRC Job Code J5728
Office of Nuclear Material Safety and Safeguards
U.S. Nuclear Regulatory Commission
Washington DC 20555-0001
Availability Notice
Abstract
The U.S. Nuclear Regulatory Commission Division of Spent Fuel Management issued Interim Staff Guidance (ISG) 8, Revision 3 in September 2012. This ISG provides guidance for NRC Staff review of burnup credit analyses supporting transport and dry storage of pressurized water reactor spent nuclear fuel (SNF) in casks. ISG-8, Rev. 3 includes, among other things, guidance for addressing validation of criticality (keff) calculations crediting the presence of a limited set of fission products and minor actinides (FP&MA). Based on previous work documented in NUREG/CR-7109, ISG-8, Rev. 3 includes a recommendation to accept use of 1.5 or 3% of the FP&MA worth, depending on the criticality code and cross-section data used, to conservatively account for the bias and bias uncertainty associated with the selected insufficiently validated FP&MAs. This bias is applied in addition to the bias and bias uncertainty resulting from validation of keff calculations for the major actinides in SNF. The work described in this report involves comparison of FP&MA worths calculated using SCALE and Monte Carlo N-Particle (MCNP) with Evaluated Nuclear Data Files, Part B–V, –VI, and –VII based nuclear data. The comparison supports use of the 1.5% FP&MA worth bias when either SCALE or MCNP codes are used for criticality calculations, provided the other conditions of ISG-8, Rev. 3, Recommendation 4 are met. The additional conditions include that the cask design is similar to the hypothetical generic burnup credit-32 cask model and that the credited FP&MA worth is no more than 0.1 Δkeff.
Page Last Reviewed/Updated Thursday, March 25, 2021